Calibration of sensor and LiqTec
Step
Action
Check that the sensor is correctly connected to the LiqTec,
1
see page 13.
Before fitting the sensor in the pump, submerge the sen-
sor into stagnant water. Any kind of container with water
can be used.
2
Note: It is important that the water is stagnant as the
calibration will be misleading if the sensor is cooled by
flowing water.
Keep the buttons, pos. 6 and 12, pressed for approx.
3
20 seconds.
When the green indicator lights, pos. 3 and 9, are con-
4
stantly on, stop pressing the buttons, pos. 6 and 12.

Further information

Information related to IEC 60 730-1:
• Software class A.
• Pollution degree 2.
• Type 1.
The LiqTec has been cURus approved according to
UL 508.
Maximum pressure:
Maximum liquid temperature:
Maximum ambient temperature:
Power consumption:
Enclosure class:
Maximum cable length:
Standard cable:
Extension cable:
Product number:
Disposal
Disposal of this product or parts of it must be carried
out according to the following guidelines:
1. Use the local public or private waste collection ser-
2. In case such waste collection service does not exist
580 psi (40 bar).
+266°F ±9°F
(+130°C ±5°C).
+131°F (+55°C).
5 Watt.
IP X0.
65.6 feet (20 m).
16.4 feet (5 m).
49.2 feet (15 m).
96443676.
Result
All red indicator lights (except pos. 7)
start flashing.
The calibration is completed.