SUN2000 (8KTL-28KTL)
User Manual
The alarm severity is defined as follows:
For details, see
Table 8-2 Rectifying common faults
Alarm
ID
103
106 to
111
120 to
125
Issue 07 (2014-07-30)
Major: The SUN2000 enters the shutdown mode and disconnects from the power grid to
stop generating electricity after a fault occurs.
Minor: Some components are faulty but the SUN2000 can still generate electricity.
Warning: The SUN2000 output power decreases due to external factors.
Table
8-2.
Alarm
Alarm
Name
Severit
y
DC
Major
Over
Voltage
String
Warnin
1-6
g
Abnorm
al
String
Warnin
1-6
g
Reverse
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Causes
Too many PV modules
connected in series lead
to excessively high
output voltage of PV
arrays, making the open
circuit voltage of the PV
arrays greater than the
maximum input voltage
of the SUN2000.
PV arrays are
shielded for a long
time.
PV arrays
deteriorate.
The cables between PV
arrays are connected
reversely during
SUN2000 installation.
8 Maintenance
Measures
Check whether the large
number of PV modules
connected in series make the
open circuit voltage of the PV
arrays greater than the
maximum input voltage of the
SUN2000. If yes, adjust the
number of PV arrays
connected in series to
decrease the output voltage of
PV arrays to meet the voltage
requirements for the
SUN2000. If no, contact
Huawei technical support.
After the adjustment, ensure
that the SUN2000 works
properly.
1. Check whether the output
current of a PV array is
obviously less than the
output current of other PV
arrays.
2. If yes, check whether the
PV array is shielded.
3. If the PV array is clear
and is not shielded, check
whether the PV modules
are faulty.
Check whether the cables
between PV arrays are
connected reversely. If they
are connected reversely,
reconnect the cables properly.
109