Download Print this page
JABSCO 23230-2012 Installation Instructions

JABSCO 23230-2012 Installation Instructions

Gear puppy

Advertisement

Quick Links

FEATURES:
Medium duty pumps for general purpose
use.
ISO 8846 MARINE (Ignition protection)
l
Maximum viscosity 150Cs
l
Inlet filter included
l
Simple design means fewer wearing
l
parts
24.5 lpm (6.5 US gpm) output @ 5m (16.4ft)
l
head
Self priming to 1.0m (3 ft)
l
Ideal for water, oil and diesel transfer
l
GEAR PUPPY PERFORMANCE
Approximate performance for new pump,
running water at 20°C with fully charged battery
TOTAL HEAD
m
ft
0
0
5
16.4
10
33
15
49
20
65
WARNING:
repeatedly do not fit a heavier fuse or
bridge the fuse terminals with silver
paper or metal wire. Failure to observe
this instruction may result in a fire
hazard due to overheating of cables.
WARNING: Do not use any Jabsco
pump for petrol, petroleum products or
any products with a flash point below
37°C (98°F), explosion or death may
occur.
GEAR PUPPY
lpm
US gpm
26
6.9
24.5
6.5
22.5
6.0
20
5.3
17
4.5
If
the
fuse
fails
MODELS:
23230-2012 12 Volts DC
23230-2024 24 Volts DC

INSTALLATION INSTRUCTIONS

Jabsco Gear Puppy can be mounted on any flat
surface. Fit the pump
position. If installed in a vertical position the motor
must be above the pump head. Use the rubber
grommets provided to minimise vibration, do not
overtighten the mounting screws.
Secure 16mm (
5 /
ports using stainless steel hose clamps. Use spiral
reinforced hose (with a smooth internal bore) that will
not collapse under suction, or rigid or semi rigid
pipework systems. The pipework must be compatible
with the liquid being pumped. Pipe runs should be
kept as straight and short as possible, avoiding rising
and dipping over obstructions. Fit a filter on the inlet
to prevent debris from entering the pump.

WIRING INSTRUCTIONS

Make all electrical connections in dry locations,
connections in humid environments should be sealed
to prevent corrosion. Protect the circuit with a
correctly rated fuse or circuit breaker in the red
positive (+) lead as close as possible to the power
source. Connect the black motor wire to the negative
(-) battery terminal. Inadequate voltage at the motor
terminals when the pump is running (not less than
10% below rated voltage at full load) due to partially
discharged batteries or insufficient cable size may
result in blowing fuses, failure to start or poor pump
performance.
WARNING:
discharging
installed with the overboard discharge
well above both static and heeled
waterlines.
GEAR PUPPY
in a dry, well ventilated
") id hose direct to the discharge
8
All
marine
overboard
:
pumps
must
be

Advertisement

loading

Summary of Contents for JABSCO 23230-2012

  • Page 1: Installation Instructions

    23230-2024 24 Volts DC FEATURES: INSTALLATION INSTRUCTIONS Medium duty pumps for general purpose Jabsco Gear Puppy can be mounted on any flat surface. Fit the pump in a dry, well ventilated use. position. If installed in a vertical position the motor must be above the pump head.
  • Page 2 CANADA Tel : +1 519 821 1900 Fax : +1 519 821 5316 ITT Industries NHK Jabsco Co Ltd, 3-21-10, Shin - Yokohama, Kohoku-ku, Yokohama 222 JAPAN Tel : +81 (0) 45 475 8906 Fax : +81 (0) 45 475 8908 Jabsco GmbH Oststraße 28, 22844 Norderstedt...

This manual is also suitable for:

23230-2024