5
Receiver RECV: Set receiving mode
!
The integrated external voltage warning (Q) of the receiver must not replace checking for zero
voltage!
5A
Mains voltage recognition
This mode works without a sender and is activated by pressing button 16. „NVC"
appears on the LCD. This mode can be used to specifically locate live lines.
The strength of the electromagnetic field is displayed as bars. An additional acoustic
receiver signal indicates in various pitches how far away the live cable is. The higher
the pitch, the closer the live cable is. If external voltage is present, a warning symbol
(Q) is displayed.
5B
Automatic search mode
This mode only works with the sender. It is active as soon as the device is turned
on and the LC display shows „SIG". The device automatically sets the sensitivity
in order to achieve optimal measuring results. Select this setting by pressing the
Mode button.
The signal strength is indicated in bars and may be read numerically. An additional
acoustic receiver signal indicates in various pitches how far away the desired cable
is. The higher the pitch, the closer the desired cable is. The numerical display is the
most exact way of locating the cable.
The sender code transmitted from the sender and the output power of the trans-
mission signal are displayed as well. If external voltage is present, a warning symbol
(Q) is displayed.
5C

Manual search mode

This mode only works with the sender and is selected
by pressing the Mode button. „SENSE" appears on the
LC display. Use the arrow keys to adjust the sensitivity:
1 arch = maximum sensitivity; 8 arches = minimum
sensitivity. Reducing the sensitivity can be useful, when
the area to be measured needs to be limited to a certain
range.
The signal strength is also determined by the output power
of the sender. Therefore, also adjust the sender level in order
to achieve the desired sensitivity.
The signal strength is indicated in bars and provides a detailed read numerically. An additional acoustic
receiver signal indicates in various pitches how far away the desired cable is. The higher the pitch, the
closer the desired cable is. The numerical display is the most exact way of locating the cable.
The sender code transmitted from the sender and the output power of the transmission signal are
displayed as well. If external voltage is present, a warning symbol (Q) is displayed.