1. DESCRIPTION
Cover
DIP Switch
Connector
Mounting Holes
Potentiometer
(Sensitivity Volume)
Area Mask
Indicator LED
4. MOUNTING PRECAUTIONS
Ensure there are no moving
If the sensor is exposed to
Mounting height of 3 m
objects in the detection zone
excessive rain install with a
(9.8ft) or lower
Hotron weather cover
3m (9.8ft)
If
possible
ensure
no
Ensure no condensation gets
Ensure
accumulation of snow or
onto the sensor.
reflected sunlight from the
water on the floor.
floor
A
B
Use different frequency settings
for sensors in close proximity
6. MOUNTING & WIRING INFORMATION
WARNING
Drilling may cause electric shock.
!
Be careful of hidden wires inside the door engine cover.
① Drill mounting (3.5mm φ ) a n d
② Remove cover using
wiring (10mmφ) holes.
a coin.
50mm
④-1 Wiring to a door controller that can
④ -2 Wiring to a door controller that
test the sensor.
Sensor's
Red
AC/DC
Cable
Power
12 to 24 [V]
Cable
(Non Pole)
Black
±10%
Yellow
Collector
Output
Blue(-)
Emitter
Gray
Test-P
Test Input
ON
Brown
Test-N
8
Set to "ON" to comply with EN16005
EN16005
⑥ Set desired sensor parameters as noted
in Sections 7 & 8.
Section 7. DIP Switch Settings
Section
8. Detection Area Width andDepth Adjustment
Disregarding this
WARNING
!
symbol may result in
DIN18650-1:2005
serious injury or death
EN 12978:2003
EN 16005:2012
Special attention is required
Note
EN16005
EC type examination
when this symbol is shown
44 205 12 414283-001
2. DIMENSIONS
Φ10mm(0.39")
-Wiring hole
75mm(2.96")
Accessories
35mm
40mm
15mm
20mm
(1.38")
(1.57")
(0.59")
(0.79")
Mounting Template
Installation
Instruction
210mm(8.27" )
Cable
3. LED INDICATORS
Green
Standby
Red
Detecting
Mounting Screws
Orange
The detection area is too close to the door
(2 pcs.)
Green/Red
Internal Sensor Error
blinking alternately
5. TECHNICAL SPECIFICATIONS
Model Name
HR94D1-C1
Detection Method
Active Infrared Detection
Installation Height
3[m] (9.8[ft]) Max
Supply Voltage
AC/DC 12 to 24 [V] ±10% Red & Black (Nonpole)
AC12V-1.8 [VA] (Max)
Power Consumption
DC12V-100 [mA] (Max)
Output Holding Time
Approx 0.5s
0.1s ~ 0.2s
Response Time
Presence Timer
DIP Switch #1, #2 (2, 30, 60, ∞ seconds)
Open collector 7.5[mA](Max) Resistor Load
DIP SW
the
minimum
of
#6 : N.C.
DIP SW
Output
#6 : N.O.
Opto coupler(NPN) Voltage:55 [VDC] Max. Current:50 [mA] Max.
Dark Current : 100 [nA] Max. (Resistance load)
Non-Test : DC12 to 24 V / Test : Open
Test Input
Operating Temperature
-20 to +60 [Deg.C],(-4 to 140 Deg.F)
Operating humidity
Below 80%
IP Rate
IP54
2 , performance level C for presence detection according to EN ISO
Category
13849-1:2008
Weight
0.190kg, ( 0.42lbs.)
Cable : 2.5m (8ft.) Mounting Screw (2pcs)
Accessories
Mounting Template User Manual
Notice: Specification may be changed without prior notice.
③ Fasten unit with mounting screws rovided.
⑤House connectors in the space provided.
cannot test the sensor.
Sensor's
Red
AC/DC
Cable
Power
12 to 24 [V]
Cable
(Non Pole)
Black
±10%
Yellow
Collector
Output
Blue(-)
Emitter
do not connect
Gray
OFF
do not connect
Brown
8
⑦
7. Place cover on sensor and clean the sensor.
7. DIP SWITCH SETTINGS
Disregarding this symbol may
CAUTION
!
result in injury or damage to
equipment
!
CAUTION
Setting required to conform with
EN16005:2012
☆ = Default Setting
Function
Dip Switch X
Presence
☆30s
Timer
5mm
(0.20")
☆
A
Frequency
3 4
Monitor
☆
Normal
Mode
30mm
(1.18")
☆
Output
N.C.
Reflection
☆
Normal
Diagnostics
Test Input
Setting
☆
OFF
from Door
Controller
AC24V-2.8 [VA] (Max)
DC24V-60 [mA] (Max)
8.DETECTION AREA WIDTH AND DEPTH ADJUSTMENT
Normally Drive (Normally Close)
SIDE VIEW/DETECTION AREA
Open on Detection
Normally Open
Drive on Detection (Close on Detection)
2.5m 2.0m 1.5m 1.0m 0.5m 0m
6 [mA] Max.@ 24 [VDC]
8.2'
6.6'
4.9'
MAX
[ 5 degree ] setting
Max Area
» The body of the sensor can be rotated from 0º~5º(3 Steps)
The above illustrated detection areas represent the actual position of the infrared beams. The actual detection area observed will vary depending on the
CAUTION
!
sensor installation environment, object been detected and sensor settings. Please ensure that the detection area is set to conform to EN16005.
9. APPLYING POWER
BEFORE APPLYING POWER, READ AND FOLLOW THESE INSTRUCTIONS:
When power is applied, the sensor will read and store the environmental optical parameters.
This is necessary for Presence Detection to work properly.
① CLEAR THE AREA OF ANY UNNECESSARY OBJECTS.
② APPLY POWER.
③ WALK AWAY FROM THE DETECTION AREA immediately.
④ DO NOT ENTER DETECTION AREA for 10 SECONDS while the "learning procedure" for Presence detection is carried out.
If the sensor can see moving objects during the "learning procedure", the sensor will not proceed to presence detection.
CAUTION
!
ON
1 2 3 4 5 6 7 8
Description
The HR94D1-C1 will detect a stationary object only for the time period
set by the Presence Timer. The timer will reset and begin if any
movement is detected.
1 2
Set the timer to 30sec. or more to comply with EN16005
EN16005
When more than two sensors are used in close
proximity to each other, select different frequency setting for each
sensors to prevent interference.
( A + B + C + D = Maximum 4 sensors )
Set to snow in instances where false door activations can result from
blowing snow, leaves or rubbish in the door close area.
5
Output logic is defined by this switch.
In the N.C. , Opto-Coupler will be driven in the state of non-
detection.
6
A low reflected infrared signal is indicated by a slow flashing Red/Green
LED.
To ignore this low reflection error state, set this dip switch to "Low
Reflection"(ON).
7
To comply with EN16005 set to "Normal"
EN16005
When connected to a door controller without a TEST input, set to "OFF".
When connected to a door controller with a TEST input, set to "ON"
Refer to [11.Timing Chart of events].
8
Set to "ON" to comply with EN16005
EN16005
Detection Area Depth Adjustment
2.5m 2.0m 1.5m 1.0m 0.5m 0m
3.3'
1.6'
0'
8.2'
6.6'
4.9'
3.3'
1.6'
0'
0
0.5m
MIN
(m)
2.0
1.6'
[ 0 degree ] setting
6.6'
1.0m
3.3'
1.5m
4.9'
2.0m
6.6'
2.5m
8.2'
3.0m
9.9'
Min Area
Please DISCONNECT POWER TO THE SENSOR, when carrying out the following work.
AFTER THE TASK, APPLY POWER AGAIN.
1. When the floor condition is changed; for example with the addition of of woolen or rubber mat.
2. Adjusting pattern or sensitivity.
Possible Setting Options
∞
☆
2s
30s
60s
1 2
1 2
1 2
1 2
☆
A
B
C
D
3 4
3 4
3 4
3 4
☆
Normal
Snow
5
5
☆
(Drive)
N.C.
N.O.
6
Transmitter
Receiver
Transmitter
Receiver
☆
Normal
Low Ref.
LED
7
7
IR Spot
IR Spot
With TEST
☆
OFF
Without TEST
Without TEST
OFF
0v
ON
ON
8
0v
7
Detection Area Width Adjustment
FRONTAL VIEW/DETECTION AREA
Area Mask
Adjustment
WIDE
NARROW
1.5
1.0
0.5
0.5
1.0 1.5
2.0
2.0
1.5
1.0
0.5
0.5 1.0
1.5
4.9' 3.3' 1.6'
1.6'
3.3'
4.9'
6.6'
6.6'
4.9' 3.3' 1.6'
1.6'
3.3'
4.9'
0
0.5m
1.6'
1.0m
3.3'
1.5m
4.9'
2.0m
6.6'
2.5m
8.2'
3.0m
9.9'
2.0
6.6'