Pronk Technologies SimCube Operator's Manual

Pronk Technologies SimCube Operator's Manual

Nibp simulator

Advertisement

Quick Links

SimCube™
NIBP Simulator
Operator's Manual
www.pronktech.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the SimCube and is the answer not in the manual?

Questions and answers

Richard Manrique
February 18, 2025

Which are references values for Suntech technologies monitor?

Summary of Contents for Pronk Technologies SimCube

  • Page 1 SimCube™ NIBP Simulator Operator’s Manual www.pronktech.com...
  • Page 2 Instrumentation products. Do not dispose of this product as unsorted waste. To dispose, contact Pronk Technologies at support@pronktech.com. A Return Material Authorization will be issued to return the unit for disposal. SimCube, Pronk, and Pronk Technologies are trademarks of Pronk Technologies Inc. ©2012 Pronk Technologies Inc. All rights reserved PRONK TECHNOLOGIES www.pronktech.com...
  • Page 3 ECG/RESP Detailed Information IBP Detailed Information (SC-5 Only) Battery Operation SimCube System Troubleshooting Tips Accessories Services Warranty and Service Information Optimizing Simulation Results With Your SimCube Oscillometric NIBP Simulator SimCube Sample Readings (Back Cover) Contact Us Sales: 800-609-9802 Technical Support:...
  • Page 4: Getting Started

    SimCube simulator to the wrong power supply may damage it. Be sure the plug has a yellow SimCube flag on it prior to connecting it to the SimCube simulator. 3. Wait for the power-up sequence to complete. When complete, the display will show 000.0 on SimCube models SC-1, SC-2, SC-3 and SC-4 and SC-5 with SW versions up to 4.5.
  • Page 5 9. For ECG and Respiration testing, connect the ECG cable from the monitor under test to the SimCube simulator. Snap locations for 3, 5 or 12 lead simulations are indicated on the side of the SimCube simulator and shown in Fig. 3. When using large snap heads or alligator clips, it may be necessary to use the ECG Extender Module, which is available from Pronk Technologies Inc.
  • Page 6: User Interface Information

    Yellow Mode button will advance to the next waveform. As an example, when in HR Seq, by placing the SimCube in the Press and Hold mode, the HR Seq will stay at 30BPM until the Yellow Mode button is pressed. Then it will advance to 60BPM. Each subsequent press of the Yellow Mode button will advance to the next waveform in the sequence.
  • Page 7 P (in mmHg); leak rate, indicated by L (in mmHg per minute); and elapsed time (in Min:Sec). In many cases the monitor must be placed in a special test mode so that it will not release the cuff pressure. PRONK TECHNOLOGIES www.pronktech.com 800-541-9802...
  • Page 8 ECG Asystole ECG Resp OFF 70/0 ECG Pacer ON 70/35 w/pacer For ECG calibration purposes, the SimCube ECG waveform output is 1 mV on the following lead / configuration (software version is displayed on boot up): SC-5 SC-4 SC-2 Calibration...
  • Page 9 Before you begin, make sure you have your SimCube setup as described in ‘Getting Started.’ The IBP interface to the SimCube simulator is a 6 pin mini DIN connector. For compact storage, each SimCube system is supplied with a single long (6’) extension cable, which can be used with a variety of short (6”) adapter cables that are sold separately.
  • Page 10: Battery Operation

    SC-5 as compared to any previous versions you may have: • The display will be slightly dimmer. • The SimCube will go into "sleep" mode when the NIBP functions are not in use, the display will go blank and the green Mode LED will flash.
  • Page 11 AC Operation When AC power is available, simply plug the SimCube power supply into an AC outlet. The Battery Boost will automatically switch over to AC and your batteries will not be drained, regardless of whether the battery boost slide switch is in the on or off position.
  • Page 12 SimCube System Troubleshooting Tips PRONK TECHNOLOGIES Revision O 07/18/2017 www.pronktech.com 800-541-9802 Page 12...
  • Page 13 The noise may point to a ground loop issue. Check for ground loop noise by running the SimCube on battery power to see if the noise still exists. If it is present, check to ECG is Noisy see that the monitor under test has its A/C filter(s) enabled.
  • Page 14 IBP Interface Cable for Nihon Kohden Monitors - This cable has a IBP-NK six pin mini-DIN to Nihon Kohden style connector. It is six inches long and works with the IBP-Extension cable. PRONK TECHNOLOGIES Revision O 07/18/2017 www.pronktech.com 800-541-9802 Page 14...
  • Page 15 Services Please Call For Pricing SC-3/4 Upgrade Service *Pronk Technologies recommends an annual calibration interval. *Extended Warranty (up to 5 years total) may be purchased only at time of original sale or with purchase of Rejuvenation Service PRONK TECHNOLOGIES www.pronktech.com...
  • Page 16: Warranty And Service Information

    Pronk Technologies shall be liable only for repair or replacement of the SimCube NIBP Simulator and optional features. Pronk Technologies shall not be liable for any incidental or consequential damages.
  • Page 17 Optimizing Simulation Results With Your SimCube Oscillometric NIBP Simulator by Karl Ruiter, Pronk Technologies Inc. Introduction out as 29mmHg. While these specifications SimCube NIBP simulator provides accurate NIBP simulation in an amazingly may seem very loose they can be quite difficult convenient, rugged, and affordable package.
  • Page 18 SimCube Simulation Results 3. Different methods for averaging pulse size. 4. Different methods for finding the peak of the The SimCube uses a simple yet effective pulse size envelope. mechanism along with a sophisticated variable pulse shape approach to deliver accurate, 5.
  • Page 19 SimCube in manometer mode. not. For example we find that some Datascope Accutorr monitors produce systolic values Be sure to watch for leaks on the SimCube's about 2mmHg higher and diastolic values manometer rather than the monitor's cuff...
  • Page 20 $ " dynamic range to reliably capture the pulses 6-7mmHg produced by the SimCube with a #1 neo cuff. # " 8-9mmHg While we have had good results with a #2 neo 10+mmHg cuff, we recommend using a loosely wrapped "...
  • Page 21 PRONK TECHNOLOGIES Revision O 07/18/2017 www.pronktech.com 800-541-9802 Page 21...
  • Page 22 PRONK TECHNOLOGIES www.pronktech.com 800-541-9802 Page 22 Revision O 07/18/2017...
  • Page 23 PRONK TECHNOLOGIES www.pronktech.com 800-541-9802 Page 23 Revision O 007/18/2017...
  • Page 24 SimCube Sample Readings Different manufacturers, different models and sometimes even different software versions can give quite different readings, but the following are some average values obtained from a variety of devices. PRONK TECHNOLOGIES www.pronktech.com 800-541-9802 Page 24 Revision O 007/18/2017...