Page 2
Part number: 026T018A Certificate is issued under the auspices of the Equipment Product Manager: Magnaflux (A Division of ITW Ltd), Faraday Road, South Dorcan Industrial Estate, Swindon, SN3 5HE, UK Tel: +44 (0)1793 524566 Fax: +44 (0)1793 490459 Email: sales.eu@magnaflux.com www.eu.magnaflux.com...
For best results, the powder should be cloud-applied near the surface • DO NOT operate the Y7 Yoke for longer than 2 minutes ON followed by 2 while the current is flowing.
Exposure to electromagnetic fields is highest within a 0.5m radius of the yoke. 1.2 FLAMMABILITY The Y7 Yoke is designed to be used in conjunction with appropriate chemicals as a means of non-destructive testing (NDT) for defects, such as cracks, on a wide range of manufactured components.
• In damp conditions, use a 100V Yoke operated from a supply that is centre- tapped to earth (55V-0-55V) • If the Y7 shows signs of malfunctioning, or if cracks appear in the casing, take the Yoke out of service immediately and have it examined by a qualified electrician.
• Familiarise yourself with thE yoke’s construction and method of operation. If Different parts and surfaces will dictate the best magnetising current, current magni- necessary, contact the manufacturer - Magnaflux GmbH - for instruction/training. tude, particle application and testing procedures to achieve good inspection results.