Oregon Scientific BPU321 User Manual
Oregon Scientific BPU321 User Manual

Oregon Scientific BPU321 User Manual

Ble upper arm blood pressure monitor

Advertisement

Quick Links

BLE Upper Arm Blood Pressure Monitor
Model: BPU321
User Manual
CONTENTS
Introduction ........................................................ 1
Package contents .............................................. 2
Accessories .............................................. 2
Product view / Key features ............................... 2
Setting up the monitor ........................................ 3
Assemble the unit ..................................... 3
Monitor settings .................................................. 3
Positioning the arm cuff................................4
Taking a measurement ...................................... 5
Understanding the reading ................................. 5
Display ...................................................... 5
Hypertension ............................................ 6
Movement / reading error ......................... 6
Voice announcement ................................ 6
View records ...................................................... 6
in memory ................................................. 7
Clear records ..................................................... 7
Deleting a single record ............................ 7
Deleting all records ................................... 7
Data transmission .............................................. 8
Manually send data .................................. 8
Unique Device ID ..................................... 8
Application.................................................9
Troubleshooting ................................................. 9
Safety and Care Instructions .............................. 9
Useful reference ............................................... 10
About blood pressure .............................. 10
Specifications ................................................... 11
About Oregon Scientific .................................... 12
Information about the CE Mark ......................... 12
Symbol description(s) ....................................... 12
EU - Declaration of Conformity......................12
FCC Statement.......................................13
Blood Pressure Log Book .......................... ......13

INTRODUCTION

Thank you for selecting the Oregon Scientific
BLE Upper Arm Blood Pressure Monitor
(BPU321). The BPU321 features multi-language
voice announcement and playback of blood
pressure measurements for added convenience
and has been designed to provide you with many
years of reliable service. The monitor can help
you measure and track the following metrics:
Systolic pressure
Diastolic pressure
Average morning / evening blood pressure
Heart rate
The monitor is able to store up to 100
measurements per user (maximum 2 users) and
equipped with the latest Bluetooth Smart
technology to achieve reliable transmission
linkage with a mobile device or tablet PC that is
with the logo
application. From now on, you can easily track
your health on a daily basis.
Readings taken by the blood pressure monitor
are equivalent to those obtained by a trained
observer using the cuff and stethoscope
TM
and corresponding

Advertisement

Table of Contents
loading

Summary of Contents for Oregon Scientific BPU321

  • Page 1: Table Of Contents

    Accessories ..........2 Product view / Key features ....... 2 INTRODUCTION Setting up the monitor ........3 Thank you for selecting the Oregon Scientific Assemble the unit ........3 BLE Upper Arm Blood Pressure Monitor Installing and replacing the batteries ..3 (BPU321).
  • Page 2: Package Contents

    1 measurement records, view This package should include the following items: additional / older records; increase value of  1 x BPU321 BLE Upper Arm Blood Pressure the setting; toggle setting options Monitor  1 x Cuff wrap : turn monitor on/off;...
  • Page 3: Setting Up The Monitor

    : monitor battery low : voice activation 10. Synchronizing status indicator light 11. Blood pressure classification bar 12. Heart rate counter : irregular heart beat detected SETTING UP THE MONITOR ASSEMBLE THE UNIT Insert the small end of the air tube into the air outlet on the monitor.
  • Page 4: Positioning The Arm Cuff

    Set the monitor by pressing the following: skin. Put arm through the cuff loop. Press to increase value or toggle options Place cuff about an inch (1-2 cm) above your elbow. to decrease value or toggle options to confirm The screen display will turn off once setting has been completed.
  • Page 5: Taking A Measurement

     It is important to relax when taking your blood Arm cuff will begin inflating automatically. pressure. Try to take a 15-minute rest before Digits will appear on the screen. you begin. Once the pressure reaches a certain level, it ...
  • Page 6: Hypertension

    An irregular heartbeat is one where there is a variance and the intervals vary. Date / Time stamp (automatically toggles) User selected Systolic pressure If an irregular heart beat has been Diastolic pressure detected during the measurement, will be Heart rate displayed.
  • Page 7: Recalling Measurements Stored

    new measurement is assigned to the first (1) Press entry in the user record selected. All other records are pushed back one digit (e.g., 2 CLEAR RECORDS becomes 3 and so on), and the last record (100) When memory is full, flashes.
  • Page 8: Data Transmission

    recommend users send data to their mobile Press and hold . dEL ONE will be device periodically. displayed. When viewing records: Press to toggle to dEL ALL  Press and hold again to confirm Press and hold deletion. Successful Unsuccessful This screen indicates all records have been transmission transmission...
  • Page 9: Troubleshooting

    other than the wrist or for functions other than TROUBLESHOOTING obtaining a blood pressure measurement. This section includes a list of error messages and • Do not confuse self-monitoring with frequently asked questions for problems you may self-diagnosis. This unit allows you to monitor encounter with your blood pressure monitor.
  • Page 10: Useful Reference

    • Remove the batteries whenever you are planning to store the unit for a long period of time. Why measure your blood pressure? • When replacing batteries, use new batteries as Blood pressure measurement can highly reflect specified in this user manual. Do not mix new and one’s health condition.
  • Page 11: How The Blood Pressure Monitor Works

    value exceeds the normal range. When a patient’s systolic and diastolic blood Then it starts inflating the arm cuff to 180mmHg pressures fall into different categories, the or higher until it senses that it has blocked your higher category should apply. blood in the artery.
  • Page 12: About Oregon Scientific

    Hereby, Oregon Scientific, declares that this BLE INFORMATION ABOUT THE CE MARK Upper Arm Blood Pressure Monitor (model: BPU321) is in compliance with the essential This device complies with the European requirements and other relevant provisions of regulations based on the Medical Products Code, Directive 1999/5/EC.
  • Page 13: Fcc Statement

    Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable Name: Oregon Scientific, Inc. protection against harmful interference in a Address: 19861 SW 95 Ave.Tualatin,...
  • Page 14 interference received, including interference that may cause undesired operation.

Table of Contents