Download Print this page

Omron ZN-KMX21 Series Instruction Sheet

Power sensor station
Hide thumbs Also See for ZN-KMX21 Series:

Advertisement

Quick Links

ZN-KMX21-
Model
Power Sensor Station
INSTRUCTION SHEET
Thank you for selecting OMRON product. This sheet primarily
describes precautions required in installing and operating the product.
Before operating the product, read the sheet thoroughly to acquire
sufficient knowledge of the product. For your convenience, keep the
sheet at your disposal.
TRACEABILITY INFORMATION:
Importer in EU:
Manufacturer:
Omron Europe B.V.
Omron Corporation,
Wegalaan 67-69
Shiokoji Horikawa, Shimogyo-ku,
2132 JD Hoofddorp,
Kyoto 600-8530 JAPAN
The Netherlands
The following notice applies only to products that carry the CE mark:
Notice:
This is a class A product. In residential areas it may cause radio
interference, in which case the user may be required to take adequate
measures to reduce interference.
* 9 5 2 1 9 5 8 - 0 E *
2011
© OMRON Corporation
All Rights Reserved.
● Perchlorate regulations by the State of California, USA
This product uses a lithium battery that contains perchlorate that is
regulated by California State Law. Appropriate measures must be taken to
comply with regulations.
For details, refer to the URL as below:
www.dtsc.ca.gov/hazardouswaste/perchlorate
PRECAUTIONS ON SAFETY
● Meanings of Signal Words
Indicates a potentially hazardous situation which, if
not avoided, will result in minor or moderate injury, or
WARNING
may result in serious injury or death. Additionally
there may be significant property damage.
Indicates a potentially hazardous situation which, if
CAUTION
not avoided, may result in minor or moderate injury or
in property damage.
● Meaning of Precaution Symbols
Mandatory Requirement
Indicates a general mandatory requirement.
Prohibition
Indicates general prohibition.
Electric Shock Warning
Warns against an electric shock under specific conditions.
Explosion Warning
Warns against an explosion under specific conditions.
Disassembly Prohibition
Indicates the possibility of accidents such as an electric shock
caused by unit disassembly.
● Warning Indications
WARNING
The mounting magnets provided with the product have
strong magnetism. If the product is mounted using these
magnets, anyone wearing a heart pacemaker must not
operate the product; or the product must not be in proximity
of such a person.
This product contains lithium batteries. Serious injury may
occur due to fire or explosion. Do not attempt to
disassemble the product, deform it by applying pressure,
heat it in a high temperature (100°C℃ or more), or burn it
for disposal.
CAUTION
Tighten the terminal screws at a recommended torque: 0.69
to 0.88N·m. Make sure that the screws are not slanted away
from the center after tightened.
A minor or moderate injury or property damage may occur
due to explosion. Do not use the product in an environment
containing an inflammable or explosive gas.
An electric shock may occur. Do not replace the batteries
when the unit is clamped to a conductor for measurement.
PRECAUTIONS FOR SAFE USE
Observe the following precautions to ensure safe operation.
• Do not install the product in the places subject to exposure to water, oil, or chemical splashes.
• Only the provided AC adapter (not other) must be used when using AC power supply.
• If a voltage that exceeds the rated voltage is applied to the AC adapter, smoking may occur. Do
not connect a power supply that exceeds the rated voltage. In a situation where a voltage
higher than the rating is applied, use protective equipment so that the power supply voltage
does not exceed the rated voltage.
• Dispose of the product as industrial waste.
• Do not let the product drop or subject it to a shock, which may cause its damage or malfunc-
tion. Use screws to secure the product when mounting it on the wall. Stop using the product if
it has been applied with a strong impact.
• When inserting or removing an SD card, securely hold the product to prevent it from dropping,
which may cause a damage. Do the same when inserting or detaching an AC adapter, alarm
output cable, or sensor connector.
• Do not bring the product close to magnetic products (e.g. magnetic cards), sensitive electronics
equipment (e.g. computers or clocks), when the product is attached with the mounting magnets.
• Small pieces may be chipped off the mounting magnets when they are attracted to the surface.
Make sure the pieces do not enter the eyes. Consult a medical doctor if this happens.
• When using the mounting magnets to install the product, take caution not to allow a finger to
be caught between the product(s) and the magnetic surface.
• Do not install the product at a high place when using the mounting magnets.
• Apply an appropriate load to the alarm output terminals to prevent possible smoking.
• If liquid crystal leaks due to a damage to the LCD panel, take caution not to allow it to contact
your skin, to be inhaled or swallowed. If it has contacted your skin or entered your mouth, seek
medical attention.
• Take anti-static electricity measures (e.g. touching grounded metal object) when handling the
product.
■ Applicable standards
・ EN61326-1
・ Electromagnetic environment : Industrial electromagnetic environment   
               (EN/IEC 61326-1 Table 2)
PRECAUTIONS FOR CORRECT USE
1. Avoid installing the product in the following places:
• Places exceeding the rated ambient temperature
• Places exposed to extreme temperature changes (where condensation occurs)
• Places subject to relative humidity exceeding the rated humidity range
• Places subject to corrosive or flammable gases
• Places subject to mist, droplets, coarse particles, fiber, salt, metal dust, or large amount of
particles
• Places subject to direct shock or vibration
• Places subject to direct sunlight
• Places subject to exposure to water, oil, or chemical splashes
• Places subject to strong magnetic field or electric field
• Outdoors
2. Wiring
• Wire the product cable separately from high-voltage or power lines. Placing them in the same
wiring or the same duct may cause induction, resulting in the product malfunction or damage.
• Make sure that the I/O terminals are inserted or removed with the power turned OFF. Doing
this with the power ON may result in a failure.
• When using a DC cable, connect the white-lined wire of the cable to the power input (24 VDC
± 3%) and the non-lined wire to 0V.
• Use a ferrite core to reduce the noise to/from other device when supplying power to the unit
via a DC cable. To use the provided DC cable, attach the provided ferrite core as shown
below.
Portable Power Monitor unit side
Power supply side
approx. 100 mm
■ Dimensions
60
Screw hook holes dimensions
40
Screw hook hole
Mounting hole process dimensions
Mounting screw hole 2-M3,
4 mm in depth
40
60
Reset switch
3. Mounting screw holes
• The screw holes provided on the product are M3 and 4 mm deep. Do not screw deeper than 4
mm, which may damage the product.
4. Operation
When using the product, also read KM series power sensor/monitor instruction sheets for
 necessary information relevant to the product.
• The Power Sensors/Monitors that can be connected to the product are KM20-B40-FLK,
KM50-C, KM50-E, KM100, KM-N1-FLK, KM-N2-FLK and KM-N3-FLK.
To directly connect KM-N1-FLK, KM-N2-FLK and KM-N3-FLK to ZN-KMX21- , please
purchase a separately sold dedicated connection cable ZN9-KMC30-N.
117.2
Sensor head connector
Power supply
input terminal
MODE key
Select key
(upper direction)
Select key
(lower direction)
SET/REC/STOP key
Display
SD card slot
Alarm output terminal
LAN port
(Unit: mm)

Advertisement

loading

Summary of Contents for Omron ZN-KMX21 Series

  • Page 1 ZN9-KMC30-N. • Places subject to strong magnetic field or electric field CAUTION Thank you for selecting OMRON product. This sheet primarily • Outdoors describes precautions required in installing and operating the product. 2. Wiring Tighten the terminal screws at a recommended torque: 0.69...
  • Page 2 Mounting upper threshold value. directions for 50 min. The installation place must be free from physical shock. screw hole *7: OMRON's XW4B-02B1-H1 connector. Power is supplied. *8: This provided AC adapter must be used. Indicates the upper limit threshold value.
  • Page 3 ■ Mounting ■ Transition of Major Menu Displays 4. Inserting the SD card Insert an SD card into the SD card connector at the bottom of the unit. Insert it with This product is precision equipment. Be careful not to drop the product when the terminal side of the SD card to the front side of the unit.
  • Page 4 Hold the MODE key for 3 seconds or more to cancel the error display. Tel: (65) 6835-3011/Fax: (65) 6835-2711 HARD Hardware error There may be a failure on the hardware. Please contact the distributor or OMRON representative office. OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road,...