Checking Product Received - Rheem RH1T2417STANAA Installation Instructions Manual

Efficiency with aluminum coil
Table of Contents

Advertisement

it is important to have the proper balance between the air being supplied to each room
and the air returning to the cooling and heating equipment.
Proper balance and sealing of the duct system improves the efficiency of the heating
and air conditioning system and improves the indoor air quality of the home by reducing
the amount of airborne pollutants that enter homes from spaces where the ductwork
and/or equipment is located. The manufacturer and the U.S. Environmental Protection
Agency's Energy Star Program recommend that central duct systems be checked by a
qualified contractor for proper balance and sealing.

2.2 CHECKING PRODUCT RECEIVED

Immediately upon receipt, all cartons and contents should be inspected for transit damage.
Units with damaged cartons should be opened immediately. If damage is found, it should
be noted on the delivery documents and a damage claim filed with the delivering carrier.
After unit has been delivered to the job site, remove the unit from the carton taking care
not to damage the unit. Check the unit rating plate for unit model number, unit size, coil
model, voltage, phase, etc. to assure the unit matches the job specifications.
2.3 MODEL NUMBER NOMENCLATURE
FIGURE 2
MODEL NUMBER NOMENCLATURE
(-) H 1 T 24 17 S
T
A
N
A
A ***
CONTROLS
N = NON-COMMUNICATING
MAJOR SERIES
A = FIRST DESIGN
B = SECOND DESIGN
METERING DEVICE
T = TXV
P = PISTON
COIL EFFICIENCY
S = STANDARD
M = MEDIUM
H = HIGH
WIDTH
17 = 17.5" (600-1200 CFM)
21 = 21" (800-1600 CFM)
24 = 24.5 (1400-1800 CFM)
NOMINAL CAPACITY
18 = 18,000 BTU/H
24 = 24,000 BTU/H*
30 = 30,000 BTU/H
36 = 36,000 BTU/H*
MOTOR TYPE
P = PSC
T = CONSTANT TORQUE
STAGES OF AIR FLOW
1 = SINGLE
PRODUCT CATEGORY
H = AIR HANDLER
BRAND
OPTION CODE
BLANK = NONE
MINOR SERIES
A = FIRST
VOLTAGE
A = 115/1/60
D = 480/3/60
J = 208/240/1/60
42 = 42,000 BTU/H
48 = 48,000 BTU/H*
60 = 60,000 BTU/H
*(-)H1T ONLY
24 = 18,000-24,000 BTU/H
36 = 30,000-36,000 BTU/H
48 = 42,000-48,000 BTU/H
7