3 The Quickly Guide

3.1 Connection

Connect G600 to antenna transfer line
Install G600 to the development board
Install GSM antenna to SMA interface
Install SIM card
Ensure the installation of nine JI2 jumper caps
Ensure the installation of JP12 jumper caps
Ensure the installation of JM9 jumper caps
Ensure the installation of JP11 jumper caps (V40EXT---V33)
Ensure the installation of JM5 jumper caps (KEY---RESET_N)
Make sure the switch of power supply is on the middle
Connect PC serial port and Main RS232 interface through serial port line
Insert the power supply adapter

3.2 Execute Hyperterminal or Another Serial's Tools on PC

 Connect the correspond serial port
Set the serial port of super termination as 115200-8-N-1-None Flow

3.3 Power Supply

LV40 LED indicator is on when power supply adapter is electrified
The switch is dialed to the direction of DC socket
LVDD LED indicator is on when the module is electrified
Press the button POWER_ON, and keep it above 600mS
LPG LED indicator and LCTS LED indicator are on when startup is success.
Input command AT in PC Hyperterminal, and return OK
Input command AT+ CSQ, and return +CSQ: 31,99 OK
The development board and G600 are on normal function. Please refer to following introduction