Operating instructions
Pressure switches for air
DL..A, DL..K
Cert. version 03.94
Contents
Contents
Pressure switches for air DL..A, DL..K. . . . . . 
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Checking the usage . . . . . . . . . . . . . . . . . . . . . 
Part designations . . . . . . . . . . . . . . . . . . . . . . . . 2
Type label. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Positive pressure measurement . . . . . . . . . . . . . 3
Negative pressure measurement . . . . . . . . . . . . 4
Differential pressure measurement . . . . . . . . . . . 4
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Function check. . . . . . . . . . . . . . . . . . . . . . . . . 5
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Z-angle bracket . . . . . . . . . . . . . . . . . . . . . . . . . 5
U-angle bracket . . . . . . . . . . . . . . . . . . . . . . . . . 6
Standard coupler plug . . . . . . . . . . . . . . . . . . . . 6
Motor flange adapter . . . . . . . . . . . . . . . . . . . . . 6
Tube set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Pilot lamp set, red or blue . . . . . . . . . . . . . . . . . 6
LED set, red/green. . . . . . . . . . . . . . . . . . . . . . . 7
External adjustment . . . . . . . . . . . . . . . . . . . . . . 7
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 7
Designed lifetime . . . . . . . . . . . . . . . . . . . . . . . . 7
Logistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Declaration of conformity . . . . . . . . . . . . . . . . . . 8
Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
E
DK
S
N
P
GR
www.docuthek.com
Safety
Safety
Please read and keep in a safe place
Please read through these instructions
carefully before installing or operating. Following the
installation, pass the instructions on to the opera-
tor. This unit must be installed and commissioned
in accordance with the regulations and standards
in force. These instructions can also be found at
www.docuthek.com.
Explanation of symbols
• ,  ,  , 3 ... = Action
= Instruction
Liability
We will not be held liable for damage resulting from
non-observance of the instructions and non-com-
pliant use.
Safety instructions
Information that is relevant for safety is indicated in
the instructions as follows:
DANGER
Indicates potentially fatal situations.
WARNING
Indicates possible danger to life and limb.
CAUTION
Indicates possible material damage.
All interventions may only be carried out by qualified
gas technicians. Electrical interventions may only be
carried out by qualified electricians.
Conversion, spare parts
All technical changes are prohibited. Only use OEM
spare parts.
Changes to edition 0.6
The following chapters have been changed:
-
Accessories
GB-1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DL 1,5A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Krom Schroder DL 1,5A

  • Page 1: Table Of Contents

    Safety Safety 344550 Please read and keep in a safe place www.docuthek.com   Please read through these instructions Operating instructions carefully before installing or operating. Following the Pressure switches for air installation, pass the instructions on to the opera- DL..A, DL..K tor.
  • Page 2: Checking The Usage

    Checking the usage Installation DL ,5 – 3A, DL 3K, DL 5 – 50A, DL 5 – 50K CAUTION For monitoring positive, negative or differential air or Please observe the following to ensure that the DL flue gas pressures. is not damaged during installation and operation: This function is only guaranteed when used within –...
  • Page 3: Positive Pressure Measurement

    [- 0.071 "WC] " NPT (+)) 2 = ø 4,75 x 1 mm (+) 3 = ø 4,75 x 1 mm (-) 1 = Rp (+), DL 1,5A e.g. SK = -0.5: (4 = Rp (-), " NPT (+)) " NPT (-)) = -0.5 + 0.18...
  • Page 4: Negative Pressure Measurement

    It can then only be operated at this power rating or higher power rating. CAUTION DL 1,5A To ensure that the DL is not damaged during opera- tion, note the switching capacity, see page  7 (Technical data).
  • Page 5: Adjustment

    DL 5 – 150A, ± 15% DL 5 – 150K  Detach the housing cover, see page 7 (Tech- ± 15% or ± 6 Pa DL 1,5A nical data). ± 15% or ± 6 Pa DL 3A, DL 3K 3 Connect an ohmmeter.
  • Page 6: U-Angle Bracket

    U-angle bracket Tube set DL 1,5 – 150A, DL 3 – 150K: Order No.: 74916185 To be used with air only. 4 7 , 5 . 9 5 " ) ( 1 . 8 7 5 ( 2 7 " ) Order No.: 74912952 M4 x 12 ( 0 .
  • Page 7: Led Set, Red/Green

    LED set, red/green Technical data DL..K2, DL..T2 Gas type: air or flue gas, no flammable gases, no aggressive gases. Max. inlet pressure = withstand pressure: see type label or page 5 (Adjustment). Micro switch to EN 61058-1. Switching capacity: 24 V DC, I = 16 mA; 24 V AC, I = 8 mA, DL..: 24 V (min.
  • Page 8: Logistics

    FM approval Logistics Transport Protect the unit from external forces (blows, shocks, vibration). On receipt of the product, check that the Factory Mutual Research Class: 3510 Flow and delivery is complete, see page  2 (Part designa- pressure safety switches. tions). Report any transport damage immediately. Designed for applications pursuant to NFPA 85 and Storage NFPA 86.

This manual is also suitable for:

Dl 3atDl 3ktDl 5aDl 5kDl 5atDl 5kt ... Show all

Table of Contents