Introduction
The Galaxy V-Plex Interface supports 128 sensors and 64 outputs. If required additional V-pex interfaces can
be connected to the RS485 line.
The interface connects directly to the Galaxy RS485 communication bus, and is programmed directly from a
standard Galaxy keypad connected to the module.
Tamper
bypass
SW3
switch
Tamper
switch
SW2
PL1
Galaxy V-Plex Interface Layout
Connecting the V-Plex Interface
Connect the V-Plex Interface terminals as in
V-Plex Interface
+
-
A
B
V-Plex Connections for Panel & Keypad Terminals
V-Plex Tamper
If the Galaxy panel is not in Engineer Mode, removing the lid of the enclosure will cause a tamper alarm.
Switch SW2 can be used to temporarily bypass the tamper switch. Closing SW3 will bypass the tamper
protection.
Honeywell Security - Newhouse Industrial Estate - Motherwell - Lanarkshire - ML1 6SB - UK
PANEL
KEYPAD
PL 2
SW4
Programming
Processor
Retaining slot
switch
, below:
V-Plex Connections
Connected to
+12 V (at control panel, keypad or remote
power supply)
0V or ground (at control panel, keypad or
remote power supply)
To the A terminal of the previous module on the
line (or the control panel if the V-Plex Interface
is the fi rst module on the line)
To the B terminal of the previous module on the
line (or the control panel if the V-Plex Interface
is the fi rst module on the line)
Programming
Entering Programming Mode
To enter V-Plex Interface Programming Mode:
Ensure that the Galaxy panel is in Engineer Mode.
1.
Address a keypad as 0 and connect it to the keypad terminals of the V-Plex Interface.
2.
Close the programming switch (SW4).
3.
The V-Plex Interface is now in Programming Mode and the keypad displays a language selection option.
Alternative programming
keypad socket
Language Selection
V-Plex bus
connection
Galaxy V-Plex Interface Programming Menu
OPTION 10 - PROG MODULE
OPTION 11 - Cold Start
This option loses all programming by restoring the Non-Volatile Memory to the default values.
OPTION 12 - RIO Address
This option allows the programming of up to 16 simulated RIO modules. The RIO address must be
enabled to allow zone and output programming of its zone and output addresses. An enabled address is
shown as ■; a disabled address is shown as □.
After a cold start, or with a new module, all addresses are disabled.
LANGUAGE SELECT
00=ENGLISH
03=ITALIANO
01=NEDERLANDS
04=FRANCAIS
02=SVENSK
05=FLEMISH
10 = PROG MODULE
11 = Cold start
12 = RIO Address 00-15
20 = PROG ZONES 001-128
1 = Type
2 = Loop No
3 = Device ID
30 = PROG OUTPUTS 001-154
1 = Type
2 = Device ID
Part No.II1-0077 Rev. 2.01
06=ESPANOL
07=CZECH
08=SLOVAK
A=YES
B=NO
0 = Disable
1 = Enable
0 = Serial Poll
1 = Dip SW Poll
1 = Loop 1
2 = Loop 2
1 = Manual
2 = Self learn
0 = Serial Poll
1 = Dip SW Poll
Enter Number
p. 1

Advertisement

loading

Summary of Contents for Honeywell Galaxy V-Plex Interface

  • Page 1 Programming Introduction The Galaxy V-Plex Interface supports 128 sensors and 64 outputs. If required additional V-pex interfaces can Entering Programming Mode be connected to the RS485 line. To enter V-Plex Interface Programming Mode: The interface connects directly to the Galaxy RS485 communication bus, and is programmed directly from a Ensure that the Galaxy panel is in Engineer Mode.