FUNCTION SETTINGS

12-1.

INDOOR UNIT

DIP SW
Jumper Wire
SWITCH POSITION

MAIN PCB

DIP-SW SETTING
Remote controller address setting
z
A number of indoor units can be operated at the same time using a wired remote controller.
Set the unit number of each indoor unit using the DIP switches on the indoor unit circuit board.
(See the following table.)
Remote controller address
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
INDOOR UNIT
1
2
Remote controller address setting
3
4
JM1
JM2
Setting forbidden
JM3
Indoor unit Printed circuit board
(  . . .Factory setting)
DIP switch No.
1
2
3
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
- (01 - 30) -
4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON