JUMO dTRANS S08 03 Operating Manual
JUMO dTRANS S08 03 Operating Manual

JUMO dTRANS S08 03 Operating Manual

Signal/isolating converter series 6 mm

Advertisement

Quick Links

JUMO dTRANS S08 XX
Signal/isolating converter series 6 mm
707203, 707204, 707205, 707208, 707209
ZONE 2
Zone 2
Operating Manual
70720300T90Z001K000
V1.00/EN/00698691

Advertisement

Table of Contents
loading

Summary of Contents for JUMO dTRANS S08 03

  • Page 1 JUMO dTRANS S08 XX Signal/isolating converter series 6 mm 707203, 707204, 707205, 707208, 707209 ZONE 2 Zone 2 Operating Manual 70720300T90Z001K000 V1.00/EN/00698691...
  • Page 2: Table Of Contents

    Mounting and demounting of JUMO dTRANS T/S08 ........
  • Page 3: Warning

    To avoid explosion and serious injury: Modules having mechanical failures must be returned to JUMO GmbH & Co. KG for repair or replacement. Repair of the device must be done by JUMO GmbH & Co. KG only. In applications where hazardous voltage is connected to in-/outputs of the device, sufficient spacing or isolation from wires, terminals and enclosure - to surroundings (incl.
  • Page 4: Ul Installation

    A power switch should be easily accessible and close to the device. The power switch shall be marked as the disconnecting unit for the device. JUMO dTRANS T/S08 must be mounted on a DIN rail according to EN 60715. UL installation Use 60/75°C copper conducters only.
  • Page 5 When disconnected, the device may be cleaned with a cloth moistened with distilled water. Liability To the extent the instructions in this manual are not strictly observed, the custom er cannot advance a demand against JUMO GmbH & Co. KG that would otherwise exist according to the concluded sales agreement.
  • Page 6: Flexible Supply

    Protective fuse: 2.5 A. Protective fuse: 0.4 A. Power rail solution #1: Alternately, you can connect 24 VDC to any one JUMO dTRANS T/S08 device with power rail connector which will then energize other units on the rail. External fuse characteristics: The 2.5 A fuse must break after not more than 120 seconds at 6.4 A.
  • Page 7: Mounting And Demounting Of Jumo Dtrans T/S08

    Mounting and demounting of JUMO dTRANS T/S08 Picture 1: Mounting on DIN rail / power rail. Click the device onto the rail. Picture 2: Demounting from DIN rail / power rail. First, remember to demount the connectors with hazardous voltages.
  • Page 8: Installation On Din Rail / Power Rail

    The devices in the JUMO dTRANS T/S08 series can be installed on a DIN rail or on a power rail. For marine applications the devices must be supported by a module stop (TN: 00697615). Power supply units can be mounted on the power rail according to customer requirements.
  • Page 9: Side Label

    Side label V1.00/EN/00698691 - 70720300T90Z001K000...
  • Page 10: Applications

    • Possibility of loop supply output Applications The JUMO dTRANS S08 isolator family are designed for the automation and process industries. These devices are the result of extensive development and test procedures making them very well suited for conversion and galvanic isolation in the following applications: •...
  • Page 11: Product Overview

    Product overview Type no. JUMO dTRANS S08 03 JUMO dTRANS S08 04 JUMO dTRANS S08 05 Product name Isolated repeater Isolated converter Isolated converter Description Fixed loop isolator / repeater. Loop isolator / converter for Loop isolator / converter for standard DC signals.
  • Page 12: Order

    Operating temperature ....... . -25°C to +70°C Operating temperature, JUMO dTRANS S08 05 ....0 to +70°C Storage temperature .
  • Page 13 Load, JUMO dTRANS S08 03, S08 04 & S08 05....≤ 600 Ω Load, JUMO dTRANS S08 08 & S08 09 ..... . . ≤ 300 Ω per channel Load stability .
  • Page 14 *IECEx ......... . DEK 18.0006 X * Does not apply to JUMO dTRANS S08 05...
  • Page 15: Connections

    Connections Input Output ch. 1 Output Supply ch. 2 81 82 83 84 85 JUMO JUMO JUMO JUMO JUMO Input signals dTRANS dTRANS dTRANS dTRANS dTRANS S08 03 S08 04 S08 05 S08 08 S08 09 Current Voltage JUMO JUMO...
  • Page 16: Led Indication

    LED indication The device is equipped with a green power LED in the front to indicate the operation status, see the table below. Output and Condition Action required loop supply Connect supply / No supply / device error De-energized replace device 1 Flash Power-up or restart De-energized...
  • Page 17: Dip-Switch Programming

    DIP-switch programming The devices JUMO dTRANS S08 04, S08 05 and S08 09 can be configured via DIP-switches. The DIP-switches are located on the side of the device and can be adjusted with a small screwdriver or other implement. Adjustment of DIP-switches.
  • Page 18: Jumo Dtrans S08 05

    JUMO dTRANS S08 05 Input setup Output setup 0…20 mA 0…20 mA 4…20 mA 4…20 mA 0…10 V 0…10 V 2…10 V 2…10 V 0…5 V 0…5 V 1…5 V 1…5 V JUMO dTRANS S08 09 Input setup Output setup...
  • Page 19 JUMO GmbH & Co. KG JUMO Instrument Co. Ltd. JUMO Process Control, Inc. Street address: JUMO House 6733 Myers Road Moritz-Juchheim-Straße 1 Temple Bank, Riverway East Syracuse, NY 13057, USA 36039 Fulda, Germany Harlow, Essex, CM20 2DY, UK Delivery address:...

This manual is also suitable for:

Dtrans s08 04Dtrans s08 05Dtrans s08 08Dtrans s08 09