Altronix 6062 Installation Instructions page 2

Multi-purpose timer

Advertisement

Fig. 1 - Timed Door Annunciator:
For this application Switch #1 and Switch #4
should be in the OFF position.
Fig. 2 - Guard Tour Supervisory Timer:
For this application Switch #1 and Switch #4
should be in the OFF position.
Fig. 3 - Swinger Eliminator:
For this application Switch #1 should be in the OFF position
and Switch #4 should be in the ON position.
Fig. 4 - Delay Timer: Use for Door Ajar Alarm, Delayed
Activation of Digital Dialer, Defrost Cycle Timer, etc...
For this application Switch #1 should be in the ON position
and Switch #4 is not used in this application.
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
web site: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A.
II6062 - Rev. 032211
6062 Typical Applications:
+
CHIME
- - -
+
Pos (+) and Neg (- - )
terminals constant
12VDC or 24VDC
- - -
Normally Open
Door Contacts
DIALER OR
TRANSMITTER
+
Pos (+) and Neg (- - )
terminals constant
12VDC or 24VDC
- - -
Normally Open
Switch Contacts
Closed
Circuit
Zone on
Control Panel
+
Pos (+) and Neg (- - )
terminals constant
12VDC or 24VDC
- - -
Protective
Circuit
Use appropriate contacts
to reporting devices
Normally Open
Triggering Device
+
Pos (+) and Neg (- - )
terminals constant
12VDC or 24VDC
- - -
Fig. 5 - Timed Door Strike:
For this application Switch #1 should be in the OFF
position and Switch #4 should be in the ON position.
Fig. 6 - Timed Shunt for a Door: Use to bypass alarm contacts.
For this application Switch #1 should be in the OFF
position and Switch #4 should be in the ON position.
Fig. 7 - Bell Cut Off Timer:
For this application Switch #1 should be in the ON position and
Switch #4 is not used in this application.
Fig. 8 - Closed Circuit Trigger Option:
For this application a resistor [for 12VDC - 2K (2,000 ohm)
or for 24VDC - 4.7K (4,700 ohm)] must be installed as shown
(resistor not supplied).
C22K
+
Pos (+) and Neg (- - )
terminals constant
+
- - -
12VDC or 24VDC
- - -
Door Strike
Normally Open
Door Contacts
Door Contacts
Protective
Circuit
+
Pos (+) and Neg (- - )
terminals constant
12VDC or 24VDC
- - -
Normally Open
Switch Contacts
+
Bell
or
Siren
- - -
Bell
Output
Control Panel
12VDC or 24VDC
+
Power
Supply
- - -
Pull up
Resistor
Closed
Circuit
Contact