voltage rating that matches the rating label on the appliance. This provides the best performance and also
prevents overloading house wiring circuits that could cause a fire hazard from overheating. Never unplug
the appliance by pulling on the power cord. Always grip the plug firmly and pull straight out from the
receptacle. Repair or replace immediately all power cords that have become frayed or otherwise
damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either end.
When moving the appliance, be careful not to damage the power cord.

Extension Cord

Because of potential safety hazards under certain conditions, it is strongly recommended that you do not
use an extension cord with this appliance. However, if you must use an extension cord, it is absolutely
necessary that it be a UL/CUL-Listed, 3-wire grounding type appliance extension cord having a grounding
type plug and outlet and that the electrical rating of the cord be 115 volts and at least 10 amperes.
Clean the unit before using it, and be sure it is level.
All four feet are adjustable, so be sure the unit is level before operation.
After moving the unit, let it stand for at least 2 hours before switching it on.
Connect the unit to a power supply. Be sure the doors are closed. After about 2 hours, the
temperature inside the cabinet should be suitable for normal use, but in any case, keep the unit empty
for at least an hour after power is connected.
 If power is disconnected, do not try to restart the unit within 5 minutes of the power disconnect.
 Do not make holes through the walls of the unit in order to mount other items.
 Avoid splashing water on the unit.
 Do not store medical or pharmaceutical products in the unit.

Temperature Control

The temperature inside the SCFR100MAN is controlled by a dial thermostat located on the front of the
unit, near the bottom. The operating temperature range is from 34°F to 45°F.

Storing Items in the Unit

Beer can be stored in the eight chrome baskets.

Defrosting the Unit

The SCFR100MAN must be defrosted manually. If you find that frost inside the unit has built up to a
thickness of ¼" to ½", disconnect the power line and remove the contents. Leave the doors open while
the frost melts. There is a drain hole at the bottom of the unit. Do not use a sharp or metallic scraper to
remove the frost buildup, but a plastic scraper is acceptable. Use a sponge or toweling to absorb any
leftover melt water and be sure the interior is dry before you reconnect and refill the unit.