3.10.2 CHIP
CONVEYOR POWER
AND CONTROLS
62
7. Adjust the machine height (during leveling and installation) to minimize the gap (or
overlap) between the coolant tank face and the machine sheet metal, (Figure 3-17:
Minimize Gap of Overlap).
Gap
Figure 3-17: Minimize Gap or Overlap
8. Coolant, wash down and flood pumps are connected per normal installation/setup.
9. A standard 55 gallon drum can be positioned underneath the conveyor discharge to
collect the chips.
NOTE
The conveyor must be plugged into the provided outlet on the VMC which is dedicated for the chip
conveyor.
1. The control has 3 operating positions:
Forward
- Controls the forward motion of the conveyor belt
Stop/Reset
- Shuts off the conveyor
Reverse
- Reverses direction of the conveyor belt (for clearing jams)
INSTALLATION PROCEDURE