Limited Warranty ............................7 Ratings and Specifications ..........................8 Introduction ..............................8 How the Smart Controllers Communicate with the RollSeal Automatic Doors........9 Smart Controller User Interface ........................9 The Power Switch ........................... 9 The Display Indicator ........................... 10 Interpreting the Display Indicator ......................
Read and understand this manual in its entirety before proceeding. Failure to observe this precaution could result in severe bodily injury or loss of life. Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 3 of 44...
Page 4
Manufacturer’s Owner’s Manual. An improperly operating or balanced door can cause severe injury or death. Have trained door systems technician make repairs to cables, spring assemblies, and other hardware. SAVE THESE INSTRUCTIONS. Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 4 of 44...
Page 5
équipement. Lu et comprendre ce manuel en entier avant que procéder. Manque à observer cette précaution peut résulter dans dommage corporel sévère ou perte de vie. Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 5 of 44...
Page 6
Formez les technicien de systèmes de porte faitez les réparations per les câbles, réunions de source, et autre quincaillerie. SAUVEZ CES INSTRUCTIONS Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 6 of 44...
This warranty gives you specific legal rights and you may also have other rights that vary from area to area. Warrantor: RollSeal PO Box 140 1751 County Road 68 Bremen, AL 35033 Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 7 of 44...
The RollSeal SC-325 & SC-650 Smart Controllers are intelligent controllers manufactured specifically for the RollSeal RS-500 and RS-600 Automatic Doors. The Smart Controllers will provide safe opening and closing of the door by using a number of internal safety devices plus those features provided in the components of the automatic doors.
How the Smart Controllers Communicate with the RollSeal Automatic Doors. Inside the upper right housing of the RollSeal automatic doors is an encoder that sends electrical pulses to the Smart Controllers when the door is moving and the controller is in the normal operating mode.
Display Indicator that can show the operating status of the controller. This section describes some other types of displays that will occur in the normal operation of the controllers. Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 10 of 44...
Page 11
When the Smart Controller is in the Jog Mode, the display will indicate “J O G” as shown at the right. See Section 7 for a description of the Jog Mode. Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 11 of 44...
Home and Safety Limit Switches HOME SWITCH The RollSeal automatic doors contains a Home limit switch for determining the “Home” or full open position of the door. When the door is fully opened the Home limit switch is triggered to stop the door. At this position the actual reading on the Display indicator will be zero (0).
Page 13
Operation of the blowers or heaters will occur ONLY while the door is closed. Closed refers to the normal operation while the door is below Safety Beam Height. Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 13 of 44...
Page 14
This parameter can be either “Yes” or “No”. To change the Open Limit (PS2) or the Closed Limit (PS3) set this parameter to “Yes” and then proceed by pressing the Mode button. To leave the Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 14 of 44...
Up ( ) or Down ( ) buttons until the close limit is satisfactory. Depress the Mode button (●) again and the controller will exit the programming mode and return to displaying the actual position. The setup is now complete. Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 16 of 44...
While Completely at that point. Door Open (after MANUAL) Stops Door after 1-2 While OPENing Seconds Reopens door Stops Door (Immediately) While CLOSing & starts Time Delay Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 17 of 44...
Section 12.10 and 12.11 shows the connections for the directional, manual and timed switch inputs to the controller. Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 18 of 44...
“Encoder” display segment “ON” indicates that the door is operating off of two encoders; “OFF” indicates one encoder. “Health” indicates that the AC Drive is OK and that the controller is allowed to initiate door movement. Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 19 of 44...
8. Set the Open and Closed Speed and Limits, the Acceleration and Deceleration Ranges, Close Time Delay and Switch positions as discussed in Section 5 of this manual. Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 21 of 44...
Limit and Safety Switches are located Drive Motor within the interior of horizontal member. RS-500 or RS-600 Door SC-325 or SC-650 Brake Release Tension Pipes Safety Beam Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 22 of 44...
9-pole, 3 position coding switches can be set to any switch position as long as the receiver coding switch and transmitter coding switch are exactly matched. Refer to Section 12.11 for connections to the Remote Receiver. Transmitter Receiver Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 23 of 44...
The Ceiling Pull switch is normally wired to the PCB 154 Sequential Timed connection but may also be used for other switch operations when required. Refer to Section 12.11 for connections to the Ceiling/Wall Mount Pull Switch Assembly. Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 24 of 44...
Wiring Diagrams, Schematics, etc. This section contains the internal and external wiring diagrams for the Smart Controllers and where applicable the RollSeal automatic doors. 12.1 Smart Controller SC-325 V1 Layout WARNING!! Ensure The Drive AC Selection Jumper AND PCB 154 AC Selection...
Smart Controller SC-325 V2, SC-650 V1 & V2 Layout WARNING!! Ensure The Drive AC Selection Jumper AND PCB 154 AC Selection Switch Are Set Accordingly BEFORE Power Is Applied To The Controller. Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 27 of 44...
Brake Rectifer must be ordered separately, field-installed on the RS Door, and the SC controller switch & jumper settings changed accordingly. Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 29 of 44...
Using a 115 VAC brake rectifier with a 230 VAC power supply can result in damage to the mechanical brake and/or brake rectifier resulting in door failure. Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 30 of 44...
Set Accordingly BEFORE Power Is Applied To The NOTES: 115 VAC Power BackUp Ordered Controller. Separately. Power BackUp should ONLY be used with the SC-325 Controller. Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 31 of 44...
12.8 Connecting to the Automatic Doors Smart Controller – Right & Left Side Compartments Inset A Inset B Inset A Inset B Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 32 of 44...
Inset A Inset B Inset A Inset B Door #1 Inset A Manual Door #2 Inset A Timed Manual Door #1 Inset B Timed Door #2 Inset B Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 33 of 44...
Of The “Manual” Input Or The “Warning” Output Are Reconfigured For Interlock Operation And Can Not Be Used For Their Normal Functions. Operator Switches: Manual Run Door, Timed Switch and Directional Switches Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 34 of 44...
Materials And Instruction Sheet Are Removed From Inside the Controller Before Applying Power To The Controller. Failure To Follow These Instructions May Result In Equipment Damage Property Damage Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 36 of 44...
Smart Controller – Right & Left Side Moving Door Warning Light NOTE: This diagram is not applicable when the Warning Connections are used for Freezer Mode applications. Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 37 of 44...
12.14 RollSeal Automatic Door Wiring Diagram W A R N I N G ! Head Unit Must Be Properly Grounded. Manual No. 4801-5156 Rev 4-08 RollSeal SC-325 & SC-650 Page 38 of 44...