Panasonic SF-C14EX Instruction Manual

Application expansion unit exclusive for light curtain
Hide thumbs Also See for SF-C14EX:

Advertisement

Quick Links

Application Expansion Unit Exclusive for Light Curtain
SF-C14EX
Thank you very much for purchasing Panasonic products.
Please read this Instruction Manual carefully and thoroughly for the cor-
rect and optimum use of this product. Kindly keep this manual in a con-
venient place for quick reference.
English and Japanese are original instructions.
1

SAFETY PRECAUTIONS

● This product has been developed / produced for industrial use only.
● Use this product as per its specifications. Do not modify this product since
its functions and capabilities may not be maintained and it may malfunction.
● Use of this product under the following conditions or environments is
not presupposed. Please consult us if there is no other choice but to
use this product in such an environment.
1) Operating this product under conditions or environments not de-
scribed in this manual.
2) Using this product in the following fields: nuclear power control,
railroad, aircraft, automobiles, combustion facilities, medical sys-
tems, aerospace development, etc.
● When this product is to be used for enforcing protection of a person from
any danger occurring around an operating machine, the user should satisfy
the regulations established by national or regional security committees (Oc-
cupational Safety and Health Administration: OSHA, the European Stan-
dardization Committee, etc.). Contact the relative organization(s) for details.
● In case of installing this product to a particular machine, follow the
safety regulations in regard to appropriate usage, mounting (installa-
tion), operation and maintenance. The users including the installation
operator are responsible for the introduction of this product.
● Use this product by installing suitable protection equipment as a
countermeasure for failure, damage, or malfunction of this product.
● Before using this product, check whether the product performs proper-
ly with the functions and capabilities as per the design specifications.
● In case of disposal, dispose this product as an industrial waste.
2
CAUTIONS
WARNING
● Machine designer, installer, employer and operator
• The machine designer, installer, employer and operator are solely
responsible to ensure that all applicable legal requirements relat-
ing to the installation and the use in any application are satisfied.
• Whether this product functions as intended and systems including this
product comply with safety regulations depends on the appropriateness
of the application, installation and operation. The machine designer,
installer, employer and operator are solely responsible for these items.
● Engineer
• The engineer would be a person who is appropriately educated,
has widespread knowledge and experience, and can solve vari-
ous problems which may arise during work, such as a machine
designer, or a person in charge of installation or operation, etc.
● Operator
• The operator should read this instruction manual thoroughly, under-
stand its contents, and perform operations following the procedures
described in this manual for the correct operation of this product.
• In case this product does not perform properly, the operator
should report this to the person in charge and stop machine op-
eration immediately. The machine must not be operated until cor-
rect performance of this product has been confirmed.
● Environment
• Do not use a mobile phone or a radio phone near this product.
• Do not install this product in the following environments.
1) Areas with high humidity where condensation is likely to occur
2) Areas exposed to corrosive or explosive gases
3) Areas exposed to vibration or shock of levels higher than that specified
4) Areas exposed to contact with water
5) Areas exposed to too much steam or dust
● Machine in which this product is installed
• Never use this product as a safety device for a press machine in Japan.
• Do not install this product with a machine whose operation can-
not be stopped immediately in the middle of an operation cycle
by an emergency stop equipment.
• This product starts the performance after 2 sec. from the power
ON. Have the control system started to function with this timing.
● Wiring
• Be sure to carry out the wiring in the power supply OFF condition.
• All electrical wiring should conform to the regional electrical regulations and laws.
The wiring should be done by engineer(s) having special electrical knowledge.
• Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
INSTRUCTION MANUAL
MJE-SFC14EX No.0053-44V
WARNING
● Maintenance
• The periodical inspection of this product must be performed by an
engineer having the special knowledge.
● Others
• Never modify this product.
● When connecting this product to a product other than the connect-
able input device, the system does not conform to the control cat-
egory 4 basd on ISO 13849-1 (EN ISO 13849-1).
● Connect this product to the same power supply which the light curtain uses.
● Take care that wrong wiring will damage the product.
● Verify that the supply voltage variation is within the rating. Take care
that if a voltage exceeding the rated range is applied, or if an AC power
supply is directly connected, the product may get burnt or damaged.
● The DC power supply unit must satisfy the conditions given below:
1) Power supply unit authorized in the region where this product is to be used.
2) Power supply unit SELV (safety extra low voltage) / PELV (pro-
tected extra low voltage) conforming to EMC Directive and Low-
voltage Directive (In case CE Marking conformity is required.)
3) Power supply unit conforming to the Low-voltage Directive and
with an output of 100VA or less.
4) The frame ground (F.G.) terminal must be connected to ground
when using a commercially available switching regulator.
5) Power supply unit with an output holding time of 20ms or more.
6) In case a surge is generated, take countermeasures such as con-
necting a surge absorber to the origin of the surge.
7) Power supply unit corresponding to CLASS 2 (only for requiring
UL
Mark conformation).
C
US
● This product is not dust-proof / splash proof. Be sure to put this prod-
uct into a control box having IP54 construction.
● Avoid dust, dirt, and steam.
● Take care that the product does not come in contact with water, oil,
grease, or organic solvents such as thinner, etc.
● The seal as shown in the drawing on the right
is stuck to the engagement point of unit. If
the seal is peeled off or broken, this product
will not be certified as a "Safety equipment"
and will not be covered by our guarantee.
● Note that this product is applicable only in the control circuit grounded in
accordance with IEC 60204-1 and JIS B 9960-1, or in the control circuit in
which the insulation monitor unit (ground fault detection unit) is arranged.
● This product is suitable for indoor use only.
3
OUTLINE
● This is the application expansion unit which can control three differ-
ent safety outputs in combination with the light curtain.
It exhibits the following features:
1) Either PNP or NPN output can be selected with the slide switch.
2) It can be connected to the light curtain using the exclusive 8-core
connection cable with connectors.
3) A detachable spring gauge terminal is employed.
4) The three auxiliary outputs (muting output, override output and blown
lamp output) and the auxiliary output of the light curtain are incorporated.
5) The interference prevention wiring among the light curtains is pos-
sible. Maximumly three sets in series / parallel mixed connection can
be configured with the interference prevention system. The number of
total beam channels in series / parallel mixed connection is 192 max.
6) The product enables to set each function using the handy control-
ler SFB-HC (Ver. 2 or later) (optional). Refer to "
USING HANDY CONTROLLER SFB-HC (OPTIONAL)."
● This device complies with the following standards / regulations.
<EU Directives>
EU Machinery Directive 2006/42/EC
EMC Directive 2004/108/EC (Valid until April 19, 2016)
EMC Directive 2014/30/EU (Valid from April 20, 2016)
RoHS Directive 2011/65/EU
<European Standards>
EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1: 2008 (Category 4, PLe)
<International Standards>
IEC 61496-1 (Type 4), ISO 13849-1: 2006 (Category 4, PLe)
<Japanese Industrial Standards (JIS)>
JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4)
<Standards in US / Canada)>
ANSI/UL 61496-1 (Type 4), ANSI/UL 508, UL 1998 (Class 2)
CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8
<Regulations in US>
OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has
certified with the type examination certificate.
With regard to the standards in US / Canada, a NRTL, UL (Under-
writers Laboratories Inc.) has certified for
<Reference>
The conformity to JIS, OSHA and ANSI for this device has been evaluated by ourselves.
● The light curtains that can be used in combination with this product are as follows.
SF4B / SF4B<V2> series and SF4B-□-01 / SF4B-□-01<V2>
Do not open!
If this seal is removed or damaged,
the units are not recognized as safety product.
Panasonic Electric Works SUNX Co., Ltd.
FUNCTIONS
UL
Listing Mark.
C
US

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic SF-C14EX

  • Page 1: Safety Precautions

    MJE-SFC14EX No.0053-44V ● When connecting this product to a product other than the connect- Thank you very much for purchasing Panasonic products. able input device, the system does not conform to the control cat- Please read this Instruction Manual carefully and thoroughly for the cor- rect and optimum use of this product.
  • Page 2: Functional Description

    FUNCTIONAL DESCRIPTION INSTALLATION POSITION / DIRECTION / METHOD ● Use the 35mm width DIN rail to install the unit. 1. Emitter side connector ● The installation position / direction is not basically limited. 2. Receiver side connector ● Please fix this product with the DIN rail stopper MS-DIN-E (optional) 11.
  • Page 3: Timing Chart

    <Wiring for PNP output (Manual reset)> TIMING CHART Emitter side Receiver side Output polarity selection switch <Normal operation> connector connector The diagram shows operation with safety outputs 1 / 2 in manual-reset 24V DC mode. (*2) Light Emergency stop switch F.G.
  • Page 4 ● Reset operation <Blown lamp output> The diagram shows operation with safety outputs 1 / 2 in auto-reset WARNING mode. Light Design the system such that the reset switch can be operated from received Light curtain outside the dangerous area, and also where the operators can see the Light blocked entire dangerous area.
  • Page 5: Functions Using Handy Controller Sfb-Hc (Optional)

    2) Emission halt cannot be done by using the emission halt input wire of the SF4B / SF4B<V2> series. 2. Connection between a unit of light curtain and SF-C14EX 3) This product outputs the light received / blocked state under activating the <When connecting to emitter of the light curtain>...
  • Page 6: Specifications

    Application expansion unit exclusive for light curtain Light received status Light Item Model No. SF-C14EX blocked 14ms or less Connectable input device SF4B / SF4B<V2> series and SF4B-□-01 / SF4B-□-01<V2> EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4,PLe)
  • Page 7: Troubleshooting

    “ ” blinks on the Internal error of the and voltage capacity. Manufacturer’s Name: Panasonic Industrial Devices SUNX Co., Ltd. digital indicator (red) product • If the product does not work cor- Manufacturer’s Address: 2431-1, Ushiyama-cho, Kasugai, Aichi 486-0901, Japan rectly, contact our office.