AHT Kinley Translation Of The Original Operating Manual

AHT Kinley Translation Of The Original Operating Manual

Commercial refrigerating appliance
Hide thumbs Also See for Kinley:

Advertisement

TRANSLATION
OF THE ORIGINAL
OPERATING MANUAL
KINLEy
KINLEy XL
COMMERCIAL
REFRIGERATING APPLIANCE
SNo. 347363
ISO 9001: 2008, ISO 14001: 2004,
Status: 07/16
OHSAS 18001: 2007, SA 8000: 2008
www.aht.at
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Kinley and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AHT Kinley

  • Page 1 TRANSLATION OF THE ORIGINAL OPERATING MANUAL KINLEy KINLEy XL COMMERCIAL REFRIGERATING APPLIANCE SNo. 347363 ISO 9001: 2008, ISO 14001: 2004, www.aht.at Status: 07/16 OHSAS 18001: 2007, SA 8000: 2008...
  • Page 2: Overview

    2 102 x 754 x 2 293 kinley 250 (–) B 946N 2 502 x 754 x 2 293 kinley Xl kinley 210 Xl (–) B 945N 2 102 x 733 x 2 330 – 2 457 * kinley 250 Xl (–) B 946N 2 502 x 733 x 2 330 –...
  • Page 3: Table Of Contents

    TAbLE OF CONTENTS MOdEL TyPES 9. Operating the temperature controller ... 13 – OvERvIEw ....... 2 9.1.1 Danfoss electronic controller ......13 9.1.2 Adjusting the setpoint ........13 9.1.3 Assigning the bus address ......13 SAFETy 9.1.4 Defrosting (automatic, manual) ..... 14 explanation of symbols .........
  • Page 4: Explanation Of Symbols

    Explanation of symbols Safety instructions and warnings are indicated in this manual by symbols and signal words. Signal words describe the degree of risk presented by the hazard. Signal words Meaning Hazard with moderate degree of risk. May result in serious injury or even wARNING death if not avoided.
  • Page 5: Legal Notices

    Failure to adhere to the aforementioned points will also void the user’s warranty. • The obligations stipulated in the agreement, the general sales and delivery conditions of “AHT Cooling Systems GmbH” (referred to hereinafter as “AHT” for short) and the statutory requirements applicable upon conclusion of the agreement shall be valid.
  • Page 6: General Safety Instructions And Warnings

    • Work on the electrical system and refrigeration system of the cabinet may only be carried out by specialist personnel authorised by AHT. If the above is not adhered to, there is the risk of an electric shock or of inflam- mation from refrigerant leaking out.
  • Page 7 • Check the cabinet immediately after it is delivered for transport damage and that it is operating properly. If you determine any defects, you should make a complaint to the AHT service partner immediately. → You can find the service number in Chapter 16.
  • Page 8: Special Safety Instructions And Warnings For Cabinets With R-290 (Propane) Refrigerant

    • Do not use electrical appliances (e.g. wet vacuum) inside the refrigerated cabinet, except those of a design recommended by the manufacturer (explosion protection marking). • Work on the electrical system and the refrigeration system must be carried out by AHT-authorised persons only (personnel trained in the handling of flammable refrigerants). Furthermore, opening of the refrigerant circuit and extraction of the refrigerant may only be performed in well-ventilated rooms or in the open air.
  • Page 9: Instruction

    The design of the individual cabinet types may vary. bottles in freezer cabinets. Technical data can be found on the rating plate and in the brochure data sheets available from the AHT sales department. Check the cabinet immediately after it is CAUTION delivered for transport damage and that it is operat- ing properly.
  • Page 10: Unpacking And Handling

    Notes Note • This cabinet is only suitable for storing frozen and • The local AHT service partner must be contacted deep-frozen food products. Product temperature when reporting any damage.(see → Chapter 16) class L1 (–15 °C to –18 °C) for use of cabinets up to climate class 3 in accordance with ISO 23953-2.
  • Page 11: Electrical Connection

    1 litre of water. 6. Electrical connection Notes Fig. 1/2: Wall installation: KINLEY XL with refrigerator/freezer at bottom (front and side view) – symbols • It is imperative to adhere to and comply with the re- gionally applicable requirements of the local power supply company and the generally applicable nation- al standards and safety requirements.
  • Page 12: Circuit Protection

    6.2.1 Miniature circuit breakers • There are 2 connecting cables (cabinet and light) on (MCBs) the top of the KINLEY/KINLEY XL. The lower refrig- erator/freezer cabinet is provided with sockets from Miniature circuit breakers (MCBs) are provided as mini- the KINLEY/KINLEY XL. Please keep in mind that mum circuit protection for the cabinet.
  • Page 13: Residual Current Circuit Breaker/Miniature Circuit Breaker With Overcurrent Protection (Rcbo)

    9.1.1 Danfoss electronic controller Note Three keys are provided as operating elements and are • No more than 1 KINLEY/KINLEY XL and 1 other re- used as follows: frigerator/freezer cabinet should ever be connected to a residual current circuit breaker (RCCB) or a resid-...
  • Page 14: Defrosting (Automatic, Manual)

    Instruction 2.) Calling up the error code Note Press key [1] briefly. • The following applies for networked cabinets in the bus system: bus address “001” is absolutely essential. Fault code list Bus addresses should not be assigned twice. Fault code* Meaning Assigning the bus address: Controller error...
  • Page 15: Adjusting The Setpoint

    Instruction 9.2.1 Adjusting the setpoint To assign a lower bus address: press the [DOWn]key. To display the set temperature (setpoint): 6.) To accept the input: Press [SeT] key. press the [SeT] key once. To leave the setpoint display: To quit the programming level Press the [SeT] key again or wait 15 seconds.
  • Page 16: Loading

    4. Remove all loose fittings and accessories (air KINLEY 210 (–) ducts, base grids, product grids, etc.). KINLEY 210 XL (–) 5. Remove condensation. Either with a wet vacuum KINLEY 250 (–) cleaner (→ bear in mind the warning for cabinets KINLEY 250 XL (–)
  • Page 17: Cleaning

    12.1 Cabinet with leD bars required value (adjustment period: 1-2 hours) is displayed again. Note 13. Product can be stored again. • Only the authorised AHT service partner is allowed to 11.3 Cleaning change the LED bars. 13. Taking the cabinet out of wARNING...
  • Page 18: Accessories

    Instruction • Contact the AHT service partner if loud noises and/or 15. Accessories extreme vibrations occur with the cabinet. Optional accessories are available for these cabinets, • The AHT service partner has all the technical and including latest information required for a service at their dis- posal (e.g.
  • Page 19: Eu Declaration Of Conformity

    EU declaration of Conformity eU Declaration of Conformity Manufacturer: AHT Cooling Systems GmbH, Werksgasse 57, A-8786 Rottenmann, Austria Authorised representative for the technical documents: Dipl.-Ing. Reinhold Resch, Werksgasse 57, A-8786 Rottenmann, Austria Product designation: Commercial refrigerating appliance Type designation: According to the overview of the cabinet models at the beginning of the oper- ating manual (SNo.
  • Page 20 AHT Cooling Systems GmbH 8786 Rottenmann · Werksgasse 57 · Austria T +43 3614 2451 0 · Fax +43 3614 2451 8 · Email office@aht.at AHT Cooling Systems Brasil ltda. Rua Onorio Bortolato, nº 1065 · 88375-000 Navegantes – SC · Brasil T +55 (0) 11 4702 / 30 99 ·...