Download Print this page
Carrier 48SD018 Installation Instructions Manual

Carrier 48SD018 Installation Instructions Manual

Single-packared gas furnace/air conditioner system with r-22 refrigerant single- and three-phase units sizes 018-060
Hide thumbs Also See for 48SD018:

Advertisement

Quick Links

_rn to the Expertg
Installation
Instructions
NOTE:
Read
the entire
instruction
manual
before
starting
the
installation.
NOTE:
Installer:
Make
sure the Owner's
Manual
and
Service
Instructions
are left with the unit after installation.
TABLE
OF CONTENTS
Page
SAFETY
CONSIDERATIONS
........................
1
INTRODUCTION
..................................
2
RECEIVING
AND INSTALLATION
................
2-12
Check Equipment
.................................
2
Identify
Unit
...................................
2
Inspect
Shipment
................................
2
Provide Unit Support
..............................
2
Roof Curb
.....................................
2
Slab Mount
....................................
2
Ground
Mount
.................................
2
Field Fabricate
Ductwork
...........................
2
Provide
Clearances
................................
6
Rig and Place Unit
................................
6
Inspection
.....................................
6
Use of Rigging
Bracket
...........................
6
Connect
Condensate
Drain
..........................
8
Install Flue Hood
..................................
8
Install Gas Piping
.................................
9
Install Duct Connections
............................
9
Configuring
Units for Downflow
(Vertical)
Discharge
.....................................
9
Install Electrical
Connections
.......................
11
High- Voltage Connections
.......................
11
Special
Procedures
for 208-V
Operation
.............
11
Control
Voltage Connections
......................
11
Heat Anticipator
Setting
.........................
12
Transformer
Protection
..........................
12
PRE-START-UP
..................................
12
START-UP
AND TROUBLESHOOTING
...........
12-19
Check for Refrigerant
Leaks
........................
12
Start-Up
Heating
& Make Adjustments
...............
13
Check Heating
Control
..........................
13
Check Gas Input
...............................
13
Adjust Gas Input
...............................
13
Check Burner
Flame
............................
14
Airflow
and Temperature
Rise .....................
14
Heating
Sequence
of Operation
....................
14
Limit Switches
................................
18
Rollout
Switch
................................
18
Start-Up
Cooling
& Make Adjustments
...............
18
Checking
Cooling
Control
Operation
...............
18
Checking
& Adjusting
Refrigerant
Charge
...........
18
Indoor Airflow
and Airflow
Adjustments
............
19
Cooling
Sequence
of Operation
....................
19
MAINTENANCE
...............................
23-25
Air Filter
.......................................
23
Indoor Blower
and Motor
..........................
23
Flue Gas Passageways
.............................
23
Induced
Draft (Combustion
Air) Blower
...............
24
A99338
Fig. 1 - Unit 48SD
(Low NOx Model
Available)
Limit Switch
....................................
24
Burner Ignition
..................................
24
Main Burners
...................................
24
Outdoor
Coil, Indoor
('oil, & Condensate
Drain Pan
.....
24
Outdoor
Fan
....................................
25
Electrical
Controls
and Wiring
......................
25
Refrigerant
Circuit
................................
25
Indoor Airflow
. .................................
25
Metering
Devices-
Thermostatic
Expansion
Valve
....................
25
AccuRater
_" Piston
.............................
25
Liquid
Line Strainer
..............................
25
TROUBLESHOOTING
..........................
25-27
START-UP
CHECKLIST
...........................
25
SAFETY
CONSIDERATIONS
Installation
and servicing
of this equipment
can be hazardous
due to
mechanical
and electrical
components.
Only trained
and qualified
personnel
should install, repair, or service this equipment.
Untrained
personnel
can perform
basic maintenance
functions
such
as cleaning
and replacing
air filters.
All other operations
must be
performed
by trained
service
personnel.
When
working
on this
equipment,
observe
precautions
in the literature,
on tags, and on
labels
attached
to or shipped
with
the
unit
and
other
safety
precautions
that may apply.
Follow
all safety codes.
Installation
must be in compliance
with
local and national
building
codes. Wear safety glasses,
protective
clothing,
and work gloves.
Have fire extinguisher
available.
Read
these instructions
thoroughly
and follow
all warnings
or cautions
included
in literature
and attached
to the unit.
Recognize
safety information.
This is the safety-alert
symbol
_.
When you see this symbol
on the unit and in instructions
or manuals,

Advertisement

loading
Need help?

Need help?

Do you have a question about the 48SD018 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

48sd02448sd03048sd03648sd04248sd04848sd060