OPERATING INSTRUCTIONS

607 PRO Challenger

Normal Operation

Oil Reservoir
• Check oil reservoir daily and fill as required.
• Drain and clean periodically depending on use�
Temperature
• Check exhaust temperature� It must not exceed 375 degrees
Fahrenheit at any time�
Recommended RPM
• Do not operate the pump faster than the recommended RPM of
1000-1250� 1500 RPM is for intermittent use only�
• Too low of an RPM can cause the vanes to clatter (inconsistent
contact with the housing) causing wear�
Suction Valve
• To operate the suction valve, move the handle in the appropriate
direction for either vacuum or pressure; center is neutral�
Vacuum Levels
• Do not operate your pump for extended periods of time at
vacuum levels which cause the pump to exceed 375 degrees
Fahrenheit exhaust gas temperature�
Guards
• Make certain all guards are in place prior to running your pump�
Think Safety!
14 | 607 PRO Challenger Series