Multi-purpose timer with enhanced features (replaces models 6060 and 6060-24)

Advertisement

Fig. 1 - Timed Door Annunciator:
For this application Switch #1 and Switch #4 should be
in the OFF position.
Fig. 2 - Guard Tour Supervisory Timer:
For this application Switch #1 and Switch #4 should be
in the OFF position.
Fig. 3 - Swinger Eliminator:
For this application Switch #1 should be in the OFF
position and Switch #4 should be in the ON position.
Fig. 4 - Delay Timer:
Use for Door Ajar Alarm,
Delayed Activation of Digital Dialer, Defrost Cycle
Timer, etc...
For this application Switch #1 should be in the ON
position and Switch #4 is not used in this application.
Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
web site: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A.
6062 Typical Applications
+
--
+
Pos (+) and Neg (-)
terminals constant 12
--
or 24VDC
Normally open door contacts
TRANSMITTER
+
Pos (+) and Neg (-)
terminals constant 12
--
or 24VDC
Normally open switch contacts
Zone on Control Panel
Pos (+) and Neg (-)
+
terminals constant 12
--
or 24VDC
Protective
Circuit
Use appropriate contacts to reporting devices
+
Pos (+) and Neg
--
(-) terminals con-
Normally open triggering device
stant 12 or
24VDC
Fig. 5 - Timed Door Strike:
CHIME
For this application Switch #1 should be in the OFF
position and Switch #4 should be in the ON position.
Fig. 6 - Timed Shunt for a Door:
contacts.
DIALER OR
For this application Switch #1 should be in the OFF
position and Switch #4 should be in the ON position.
Fig. 7 - Bell Cut Off Timer:
Closed Circuit
For this application Switch #1 should be in the ON
position and Switch #4 is not used in this
application.
Fig. 8 - Closed Circuit Trigger Option:
For this application a 1K (1,000 ohm) resistor must be
installed as shown. (resistor not supplied)
+
+
--
--
Door Strike
Normally open door contacts
Use to bypass alarm
Door Contacts
Protective Circuit
+
Pos (+) and Neg (-)
terminals constant 12
--
or 24VDC
Normally open switch contacts
+
BELL OR
--
BELL
OUTPUT
Control Panel
12 or 24VDC
1K resistor
closed
circuit contact
Pos (+) and
Neg (-) termi-
nals constant
12 or 24VDC
SIREN
+
Power
Supply
--
MEMBER