Honeywell LKS 160 Product Handbook page 4

Actuator for air dampers on multi-stage and modulating burners
Table of Contents

Advertisement

counter-clockwise rotation
Diagram Shaft Drive
time
2 )
3 )
4 )
Nr.
Nr.
s
S1
5
5
S2
5
5
S1
5
3
S1
5
5
S2
5
3
S6
5
34
S2.1
5
5
S3.2
5
5
S4
5
5
S13
6
34
S2
5
12
S4
5
5
S2
5
8
S8.P1
5
12
S4
5
12
S6
5
5
S8.P1.1
5
34
S6.1
5
5
S4.9
5
5
S6.2
5
65
S8.P1
5
5
S12
5
30
Legend
1) when viewing from direction A (see dimensional drawing)
2) see "Circuit diagrams"
3) see "Dimensional drawing"
4) at 50 Hz for 90°
at 60 Hz, Drive times are about 20 % shorter
Technical Data
Housing
impact-proof, heat-resistant synthetic material
Colour: black
Drive motor
reversible synchronous motor
Switch point setting
stepless cam setting, lever-operated or spindle-driven
cams; if spindle-driven, with superimposed scale
Position indicator
scale
Connection system
terminal blocks
Gearing
spur gearing, maintenance-free
Drive shaft
steel
Fitting and fastening
Fastened from inside via tapped M 5 through-holes
EN2C-0112SZ20 R0202
1 )
Load torque
Holding
Voltage
torque
5 )
Nm
Nm
2,5
0,8
2,5
0,8
1,5
0,6
2,5
0,8
1,5
0,6
3
3
2,5
0,8
2,5
0,8
2,5
0,8
3
3
3
1,5
2,5
0,8
3
1,5
3
1,5
3
1,5
2,5
0,8
3
3
2,5
0,8
2,5
0,8
3
3
2,5
0,8
3
3
5)
6)
7)
Type
6 )
V
230
LKS 160-02 B 5-5 S1
230
LKS 160-04 B 5-5 S2
230
LKS 160-08 B 5-3 S2
230
LKS 160-10 B 5-5 S1
230
LKS 160-12 B 5-3 S2
230
LKS 160-18 B 5-5 S2
230
LKS 160-19 B 5-5 S2.1
110
LKS 160-28 B 5-5 S3.2
230
LKS 160-36 B 5-5 S4
230
LKS 160-43 B 6-34 S13
230
LKS 160-50 B 5-12 S2
230
LKS 160-51 B 5-5 S4
230
LKS 160-52 B 5-8 S2
230
LKS 160-57 B 5-12 S8.P1
230
LKS 160-60 B 5-12 S4
230
LKS 160-61 B 5-5 S6
230
LKS 160-69 B 5-34 S8.P1.1
110
LKS 160-71 B 5-5 S6.1
230
LKS 160-74 B 5-5 S4.9
230
LKS 160-76 B 5-65 S6.2
230
LKS 160-77 B 5-5 S8.P1
230
LKS 160-78 B 5-30 S10
under nominal conditions
under extreme conditions (e.g. +60 °C, 230V -15%) the torques will be 25% lower
+10% -15%; 50...60Hz
at -15%; torque reduced by approx. 20% at undervoltage
Standard: Lever-operated cam
PCBs
for all electrical functions, increased conductor thickness
Mains voltage
230 V -15% +10% or
110 V -15% +10%
Mains frequency
50 Hz or 60 Hz
Safety class
II VDE 0631
Power consumption
approx. 4 VA
Duty cicle
depending on motor, 50 to 70 % in 2 minutes
Interference suppression
N (according to VDE 0785)
Actuating angle
max. 90°
Mounting position
any
4
Remarks
7 )
standard version
standard version
Shaft with adapter
Spindle-driven cam
Other cam colours
Potentiometer can be retrofitted
Relays control 24 VDC
Potentiometer can be retrofitted
Face down

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents