Page 2
Do not insert foreign objects into or place heavy objects on your device. Sensitive components inside might cause damage. Do not use ArtiPad I in exceptionally cold or hot, dusty, damp or dry environments. In places using ArtiPad I may cause interference or generate a potential risk, please turn it off.
Page 3
ArtiPad I User Manual Wear an ANSI-approved eye shield when testing or repairing vehicles. The vehicle shall be tested in a well-ventilated work area, as engines produce various poisonous compounds (hydrocarbon, carbon monoxide, nitrogen oxides, etc.) Do not connect or disconnect any test equipment while the ignition is on or the engine is running.
1.2 F ....................1 EATURES 1.3 T ..............2 ECHNICAL PECIFICATIONS 2 KNOWLEDGE OF ARTIPAD I ................ 4 2.1 A ..................5 TABLET 2.1.1 Front & Rear Views ................5 2.1.2 Top View................... 6 2.3 VCI C ) ......... 7...
Page 5
ArtiPad I User Manual 4.2.1 User registration ................14 4.2.2 Job menu ..................17 4.2.3 Vehicle menu layout ............... 19 4.2.4 Diagnostics toolbar ................. 21 4.3 D ................22 IAGNOSIS ETHODS 4.4 C ..................22 ONNECTIONS 4.4.1 Preparation..................22 4.4.2 DLC location .................. 23 4.4.3 Vehicle connection .................
Page 6
ArtiPad I User Manual 6.9 B ..........58 ATTERY AINTENANCE YSTEM ESET 6.10 D (DPF) R ......59 IESEL ARTICULATE ILTER EGENERATION 6.11 E ..........59 LECTRONIC HROTTLE OSITION ESET 7 SOFTWARE UPDATE .................. 60 8 HOW TO FEEDBACK DIAGNOSTIC LOGS? ..........61 9 SENSORBOX (TOOLBOX) ................
Page 7
ArtiPad I User Manual 12.1 I ..................83 NTRODUCTION 12.2 S & A ..............84 TRUCTURE CCESSORIES 12.2.1 Scopebox structure ..............84 12.2.2 Scopebox accessories ..............85 12.3 C & I ..............86 ONNECTION NITIAL 12.3.1 Connection ................... 86 12.3.2 Initial interface introduction ............86 12.4 O...
Page 8
ArtiPad I User Manual 15.5 A ....................116 BOUT 15.6 L ..........116 OGIN XIT FROM CURRENT ACCOUNT 16 OTHERS ....................117 16.1 E ....................117 MAIL 16.1.1 Configure an email account ............117 16.1.2 Add an email account ..............117 16.2 B...
ArtiPad I User Manual 1 Introduction 1.1 Product Profile ArtiPad I is an evolutionary smart solution for passenger car diagnosis based on the multitask-capable Android operating system. Using the powerful 8-core 2.0GHz processor and a 12 inch HD capacitive touch screen, combined with the best possible coverage of OEM-level diagnostics, ArtiPad I delivers quick &...
ArtiPad I User Manual 4. Equipped with USB port for connecting USB devices and other add-on modules such as Scopebox, Sensorbox and Batterybox. 5. Web browser: Users can make online search and visit any website. 1.3 Technical Specifications A. ArtiPad I Tablet...
Page 11
ArtiPad I User Manual Dimension 70mm x 42.5mm x 20mm Weight < 100g Working Temp. -10℃ ~ 55℃(14 ~131℉) Storage Temp. -20℃ ~ 70℃(-4 ~158℉) Relative Humidity 20% ~ 90%...
ArtiPad I User Manual 2 Knowledge of ArtiPad I There are two main components to the ArtiPad I system. ArtiPad I tablet – the central processor and monitor for the system (See Chapter “2.1”). Fig. 2-1 ArtiPad I tablet ...
ArtiPad I User Manual 2.1 ArtiPad I tablet 2.1.1 Front & Rear Views Fig. 2-3 Front & Rear Views Microphone Touch Screen Front Camera Ambient Light Sensor Camera Flash Speaker Rear Camera Flip out it to any angle and work comfortable...
ArtiPad I User Manual 2.1.2 Top View Fig. 2-4 Top View Charging Slot Only reserved for Micro USB cable. To connect VCI, USB devices or add-on modules USB2 Port (Scopebox, Sensorbox or Batterybox). DC-IN Interface To connect the included power adaptor.
Bluetooth communication or USB connection. When the 2 communication methods are applied at the same time, ArtiPad I will use the USB communication as the default priority.
ArtiPad I via USB cable. 2.4 Package List Common accessories for each ArtiPad I are same, but for different destinations, the accessories of ArtiPad I may vary. Please consult from the local agency or check the packing list supplied with ArtiPad I together. Item...
3.5 Lock & Unlock Screen Many screen lock modes are available on ArtiPad I. Note: You are recommended to set screen lock as “None” since ArtiPad I is a frequently used diagnostic tool. 3.5.1 Lock the screen ...
3.8 Adjust Brightness Tips: Reducing the brightness of the screen is helpful to save the power of ArtiPad I. 1. On the home screen, tap Settings -> Display -> Brightness level. 2. Drag the slider to adjust it.
2. On the home screen, tap Settings -> Ethernet, and slide the switch to On. 3.10.2 Connect to a Wi-Fi network ArtiPad I has built-in Wi-Fi that can be used to get online. Once you’re online, you can register your ArtiPad I, browse the Internet, get and update apps and send email on your network.
Page 21
ArtiPad I User Manual If the network you chose is open, you can connect directly; If the selected network is encrypted, you have to enter the right security key (network password). When this tool is in range, it will connect to the previously linked network...
ArtiPad I User Manual 4 Initial Use 4.1 Getting Started For new users, please follow the operation chart shown in Fig. 4-1 to start using ArtiPad I. Fig. 4-1 Note*: If “VIN Scan” or “Intelligent Diagnosis” function is performed, this step shall not apply.
Page 23
ArtiPad I User Manual Fig. 4-2 (If you are a new user, follow to proceed.) (If you have registered to be a member, go to to login the system directly.) (In case you forgot password, refer to to reset a new password.) A.
Page 24
ArtiPad I User Manual Fig. 4-4 In Fig. 4-4, input the Serial Number and Activation Code, which can be found in the password envelope. Fig. 4-5 Note: To exit and activate it later, tap “Skip”. In this case, you can activate your connector by tapping “Activate Connector”...
“Login” button to enter the main menu screen directly. Note: The ArtiPad I has an auto-save function. Once the username and password are correctly entered, the system will automatically store it. Next time you login the system, you will not be asked to input the account manually.
Page 26
Software Upgrade To update vehicle diagnostic software and APK. Generally once a vehicle diagnosis is performed, ArtiPad I will automatically save every details of diagnostic process. This function provides a quick Diagnostic History access to the tested vehicles and users can resume from the last operation, without the necessity of starting from scratch.
This option aims to help repair shops or technicians Remote Diagnosis launch instant messaging and remote diagnosis, making the repair job getting fixed faster. Testable Models To view all the vehicle models that the ArtiPad I covers. Includes browser, oscilloscope, sensor, multimeter, Toolbox battery etc. Other Modules Includes product manual and FAQ.
Page 28
Recently Tab: Displays all the recently tested vehicle makes. Vehicle region buttons: Tap different buttons to switch to corresponding vehicles. If you have purchased an ArtiPad I of Commercial & Passenger Vehicle Version, a Heavy-duty tab will appear next to these buttons.
Wi-Fi Print printer separately and then properly configure the printer following the steps described in Chapter 15.3. Inquires the vehicle models that the ArtiPad I Testable Model supports. Personal Center Quick access to personal center.
Notes: While using the diagnosis via Bluetooth, the VCI connector should be paired with the ArtiPad I tablet. If no Bluetooth setting is done before diagnostic software is launched, you can also configure it while using the software. To obtain stable communication, you are strongly recommended to perform the vehicle diagnosis via USB cable.
3. Choose one of the two ways to obtain power from: A. Power adaptor: Connect one end of the included power adaptor to DC IN port of ArtiPad I tablet, and the other end to AC outlet. B. Internal battery pack...
OBD I adaptor. Fig. 4-13 4.5 Bluetooth Setting There are two kinds of ways available for ArtiPad I to pair with the VCI connector. 1. Connect one end of the USB cable (optional) to the Mini USB port of the VCI...
Page 33
5. If the Bluetooth pair request pops up on the screen, enter the request pin code (default code: 0000 or 1234). 6. Once the connector is paired with the ArtiPad I handset, “Paired” appears and the connector will be shown under the paired device tab.
• A stable network connection is required for this function. Follow the steps below to proceed. 1. Tap “Intelligent Diagnosis” on the Job menu screen to enter Fig. 5-1. Fig. 5-1 Note: If the VCI connector is not paired up with the ArtiPad I handset before doing this...
Page 35
ArtiPad I User Manual step, a prompt message box will appear: Fig. 5-2 Check all the possible reasons of Bluetooth connection failure carefully, and then tap “Confirm”. Fig. 5-3 If the VCI connector was once used with other devices, you need to cancel the pairing of the connector first via either one of the following ways: •...
Page 36
ArtiPad I User Manual Fig. 5-4 2. Once pairing is complete, the handset starts reading the vehicle VIN. A. If the VIN can be found from the remote server database, a screen similar to Fig. 5-5 displays: Fig. 5-5 • Tap “Diagnostic” to start a new diagnostic session.
Page 37
ArtiPad I User Manual Fig. 5-6 • Tap “View record” to view the details of the current diagnostic report. • To perform other functions, tap “Quick access” to directly go to the function selection screen. Choose the desired one to start a new diagnostic session.
Page 38
ArtiPad I User Manual • Tap “Scan VIN”, a screen similar to the following appears: Fig. 5-8 Place the VIN inside the viewfinder rectangle to scan it. The most recognizable location for this number is in the top left corner on the vehicle’s dashboard.
A. Camera Scan: In this mode, the VCI connector should be plugged into the vehicle’s DLC first, and then a Bluetooth communication should be established between ArtiPad I and the vehicle. Tap “Camera Scan”, a screen similar to the following appears:...
Page 40
• In case the handset failed to recognize it, tap to enter it manually. • To turn the flash on, tap Once the test vehicle is successfully identified, ArtiPad I will jump to the function selection page directly. Fig. 5-13 Tap the desired option to perform the corresponding function.
Page 41
ArtiPad I User Manual vehicle identification numbers are standardized - all contain 17 characters. VIN characters may be capital letters A through Z and numbers 1 through 0; however, the letters I, O and Q are never used in order to avoid mistakes of misreading.
Page 42
Tap “Scan” to start searching for the VCI connector. Once it is found, tap it to start pairing. If the ArtiPad I handset has paired with the VCI connector, it will enter Step 2 directly. Confirm: Tap it to go to next step.
ArtiPad I User Manual Fig. 5-17 5.2.1 Health Report (Quick Test) This function varies from vehicle to vehicle. It enables you to quickly access all the electronic control units of the vehicle and generate a detailed report about vehicle health.
Page 44
ArtiPad I User Manual Fig. 5-19 In Fig. 5-19, the tested system with fault code appears in red and the system with OK displays in black (normally). On-screen Buttons: Clear DTC: Tap to clear the existing diagnostic trouble codes. Fault Report: Tap to view the health report in details.
ArtiPad I User Manual search for more detailed information about the selected DTC online. Report: To save the current data in text format. Fig. 5-21 Input the required information, and then tap “Confirm” to save it. Alternatively you can also set the workshop information in “Personal Center” ->...
ArtiPad I User Manual Fig. 5-22 Tap the desired system to advance to the test function selection page. For detailed operations on test function, please refer to Chapter 5.2.3. 5.2.3 System Selection This option allows you manually select the test system and function step by step.
Page 47
ArtiPad I User Manual Fig. 5-24 Note: Different vehicle has different diagnostic menus. A. Version Information This function is used to read the version information of system mode, vehicle VIN, software and ECU. In Fig. 5-24, tap “Version Information”, the screen displays as Fig. 5-25.
Page 48
ArtiPad I User Manual Fig. 5-26 On-screen Buttons: Freeze Frame: When an emission-related fault occurs, certain vehicle conditions are . This information is referred to as freeze frame recorded by the on-board computer data. Freeze frame data includes a snapshot of critical parameter values at the time the DTC is set.
Page 49
ArtiPad I User Manual Fig. 5-27 Tap “Yes”, the system will automatically delete the currently existing trouble code. Note: The trouble code will not disappear until the trouble was completely cleared. D. Read Data Stream This option retrieves and displays live data and parameters from the vehicle’s ECU.
Page 50
ArtiPad I User Manual Fig. 5-29 Notes: 1. If the value of the data stream item is out of the range of the standard (reference) value, the whole line will display in red. If it complies with the reference value, it displays in blue (normal mode).
Page 51
ArtiPad I User Manual Fig. 5-30 Fig. 5-31 Report: To save the current data in text format. All reports are saved under the tab “Diagnostic Report” in “My Report” from “Personal Center” menu. For details on report operations, please refer to Chapter 15.1 “My Report”.
Page 52
This option is used to access vehicle-specific subsystem and component tests. Available test vary by vehicle manufacturer, year, and model. During the actuation test, the ArtiPad I handset outputs commands to the ECU in order to drive the actuators, and then determines the integrity of the system or parts by reading the ECU data, or by monitoring the operation of the actuators, such as switching a injector between two operating states.
Contact tab Tap to enter the friend list. WEB Remote Tap to slide the switch to ON, the ArtiPad I keeps online switch and becomes visible on the web client. In this case, inform...
ArtiPad I User Manual the technician of your product S/N, and he/she will control your ArtiPad I remotely. 5.3.2 Add Friends Tap “Contact” to enter the contact page. By default it appears blank. In the search bar, input the partner’s username and tap “Search” button next to the search bar to starts searching for it from golo business database.
ArtiPad I User Manual Tap “CONFIRM” to send your request. Once the partner receives the request, a beep will sound. Tap the “Message” tab: • Once the partner agreed your request, he/she will automatically be listed in the Contact tab.
Turn on the vehicle power supply. Throttle should be in a closed position. The ArtiPad I should be properly connected to the vehicle’s DLC and a successful communication is required. In Fig. 5-38, tap “Remote Diagnostic”, a pull-down menu including the following options appears: Fig.
Page 57
ArtiPad I User Manual These options are defined as follows: Actions Results Tap it and input the reservation title or scheduled date Send remote of the remote diagnosis, and then tap “Confirm” to diagnostic reservation send. Request to control the partner’s device remotely to help him diagnose the vehicle.
Page 58
ArtiPad I User Manual In process of remote diagnosis, tap the button to send voice message. Once you received the report from the partner, tap “View Report” to view details. All diagnostic reports are saved under the “Remote Diagnostic Reports” tab of “My Reports”...
ArtiPad I User Manual 5.3.5 Launch Remote Diagnosis (Device-To-PC) Except that the remote diagnosis can be done between different diagnostic tools that come loaded with the module, user also can ask for remote control from PC client technician. Fig. 5-40...
Page 60
2. Notify the partner of the PC client website http://remote.x431.com/cn/. When the partner accesses the link, the PC displays as below: *Note: Before processing remote diagnosis, please make sure the ArtiPad I handset is properly connected to the vehicle. Fig. 5-42...
5.4 How to view diagnostic history? Generally once a vehicle diagnosis is performed, ArtiPad I will record the every details of diagnostic process. The History function provides direct access to the previously tested vehicles and users can resume from the last operation, without...
Page 62
ArtiPad I User Manual Tap “Diagnostic History” on the Job menu screen, all diagnostic records will be listed on the screen in date sequence. Fig. 5-44 • Tap certain vehicle model to view the details of the last diagnostic report.
ArtiPad I User Manual 6 Special (Reset) Function In addition to amazing & powerful diagnostic function, ArtiPad I also features various service functions. The most commonly performed service functions contain: Oil Reset Service Electronic Parking Brake Reset Steering Angle Calibration ...
ArtiPad I User Manual Figure 6-1 6.1 Oil Reset Service This function allows you to perform reset for the engine oil life system, which calculates an optimal oil life change interval depending on the vehicle driving conditions and climate. This function can be performed in the following cases: 1.
ArtiPad I User Manual 1. When the ABS contains air, the ABS bleeding function must be performed to bleed the brake system to restore ABS brake sensitivity. 2. If the ABS computer, ABS pump, brake master cylinder, brake cylinder, brake line, or brake fluid is replaced, the ABS bleeding function must be performed to bleed the ABS.
ArtiPad I User Manual start a car’s engine, usually the ignition or the fuel supply. This is accomplished by radio frequency identification between a transponder in the ignition key and a device called a radio frequency reader in the steering column. When the key is placed in the ignition, the transponder sends a signal with a unique identification code to the reader, which relays it to a receiver in the vehicle’s computer control...
ArtiPad I User Manual accurately, which can avoid an error message displaying on the instrument panel. 6.10 Diesel Particulate Filter (DPF) Regeneration DPF regeneration is used to clear PM (Particulate Matter) from the DPF filter through continuous combustion oxidation mode (such as high temperature heating combustion, fuel additive or catalyst reduce PM ignition combustion) to stabilize the filter performance.
ArtiPad I User Manual 7 Software Update If you did not download the software in process of product registration or a pop-up message prompting you that some new software can be updated, you may use this option to download it or keep it synchronized with the latest version.
ArtiPad I User Manual 8 How to feedback diagnostic logs? This item allows you to feedback your diagnostic problems to us for analysis and troubleshooting. Tap “Feedback”, a pop-up message will appear: Fig. 8-1 Tap “CONFIRM” to choose the vehicle diagnostic record page.
Page 70
ArtiPad I User Manual Fig. 8-3 Select the check box and tap “Submit”. A screen similar to the following will appear: Fig. 8-4 Choose the failure type and fill in the detailed failure description in the blank text box and telephone or email address. After inputting, tap “Submit Result” to send it to us.
ArtiPad I User Manual 9 Sensorbox (Toolbox) 9.1 Product Summary ArtiPad I provides an optional function of automotive sensor simulation test. “Sensor” function is specially designed to diagnose and simulate vehicle sensor faults quickly and conveniently, including “DC voltage simulation”, “Fixed frequency simulation”, “Predefined waveform simulation”...
Input voltage 1~12V 9.2 Structure & Accessories 9.2.1 Sensorbox structure Fig. 9-1 Structural diagram of Sensorbox Table 9-1 shows the ports and indicators for ArtiPad I sensorbox Name Description Indicator (green) for receiving data from main Data receiving indicator unit.
Sensor test cable Sensor probe Multimeter probe Electronic control converting cable 1 Electronic control converting cable 2 Electronic control converting cable 3 Electronic control converting cable 4 9.3 Sensor Simulation 9.3.1 Connections 1. Firstly, power the ArtiPad I tablet on.
ECU, otherwise, the fault exists in ECU. After all connections are properly made (refer to Chapter 9.3.1 for details), tap the ArtiPad I application to enter the Job menu interface, then tap “Toolbox” -> “Sensor” to enter the test selection screen. See Fig. 9-2.
Page 75
After selecting or inputting the desired voltage based on the working characteristics of sensor, tap the button, then the ArtiPad I will begin to output the simulation voltages. Please note the red probe is the output terminal of simulation voltage. 2. Fixed frequency simulation This option enables you to simulate the square wave signal of pulse frequency of 0.1 ~ 15 kHz, amplitude range of -5V ~ +5V and duty cycle 10% ~ 90%.
Page 76
ArtiPad I User Manual Fig. 9-4 Here, tap button, a screen similar to Fig. 9-5 will appear. Fig. 9-5 In Fig. 9-5, the left setting column stands for sensor types and the right area displays waveform. The sensor types are explained as below:...
Page 77
, ArtiPad I will output a waveform as desired. Warning: Just draw a complete periodic waveform (when it is output, the system will regard the waveform in the drawing area as a periodic one).
ArtiPad I User Manual In Fig. 9-2, tap “Hand-painted waveform simulation”, a screen similar to Fig. 9-8 will appear. Fig. 9-8 Button descriptions: ]: Save the current waveform. ]: Loads the previously saved hand-drawn waveform. ]: Clear all hand-drawn waveform.
Page 79
ArtiPad I User Manual Before disassembling the engine electrical control system cable, cut off the power supply, that is, turn the ignition switch OFF and disconnect the cables on the battery poles. Contact the test probe and the two terminals/ the two leads to be measured when measuring the voltage between the two terminals or the two leads.
10 Multimeter (Toolbox) 10.1 Main Menu Make sure the ArtiPad I handset and the sensorbox are properly connected (Refer to Chapter 9.3.1 Connections for details), tap the ArtiPad I application and then tap “Toolbox” -> “Multimeter” to display the test menu.
ArtiPad I User Manual The following operations can be done: ]: Erases the currently displayed waveform and display it starting from the left. ]: Reduces the range and zoom in the waveform. ]: Increase the range and zoom out the waveform.
Page 82
ArtiPad I User Manual compliant with the standard, then the coolant temperature sensor shall be replaced. (2) Output signal voltage testing for coolant temperature sensor After installing the coolant temperature sensor, plug the wire connector of sensor, and then switch ignition ON, test the output signal voltage between the two terminals of wire connector.
11 Batterybox (Toolbox) 11.1 Product Summary ArtiPad I provides an optional function of automotive battery test, which adopts the latest state-of-the-art conductance testing technology in the world and can test vehicle’s battery status. Two testing environments (Inside the Vehicle and Outside the Vehicle) are available and applicable to battery test.
ArtiPad I User Manual 11.2 Test Environment 11.2.1 Test environment Inside the vehicle test indicates that the battery connects to loading devices, such as engine, etc. After doing battery test, it can perform charging system and actuation system test, which is proceeded as a whole simultaneously. Charging system and actuation system test is not required but must not be performed before battery test.
11.3.1 Batterybox structure Fig.11-1 Batterybox structure diagram 1. Battery connector: Connect to vehicle’s battery for battery test. 2. B type USB terminal: Connect to the ArtiPad I tablet with a B-shaped USB cable. 11.3.2 Test accessories Fig. 11-2 Kelvin clip Fig.
ArtiPad I User Manual initialize after connection is complete, otherwise, communication may fail. 2. Red lamp on the batterybox means it has been successfully powered up; If the green light is always on, it indicates the clip is well connected; while the green light blinks, it indicates that the clip has poor contact.
Page 87
ArtiPad I User Manual 5. Follow the on-screen instructions to turn off the headlamp and tap [OK], the system will continue the testing. Tap , it will enter testing standard selection screen. Fig. 11-5 6. Select a testing standard except for JIS and tap , a screen similar to Fig.
Page 88
ArtiPad I User Manual Fig. 11-7 ]: Tap it to perform the charging system and starting system test. ]: Tap to test it again. ]: Tap it to reset the test. 2. Charging system and starting system test While performing this test, the battery’s charging voltage value and starting voltage can be obtained in case of engine starting and accelerating.
ArtiPad I User Manual Fig. 11-9 Tap [OK], test data will be shown on the screen. Notes: It is unnecessary to perform charging system and start system test after finishing battery test, but battery test must be done before undergoing charging system and starting system test.
Page 90
ArtiPad I User Manual equipments are needed. To validate the accuracy of the value, the best method is to collect the signals of starting and charging voltage and observe it on an oscillometer. Generally, the voltage is lower than 11V for the bad cell battery, but it is possible that the battery is completely exhausted or has a serious low capacity.
ArtiPad I User Manual 12 Oscilloscope (Toolbox) 12.1 Introduction The Scopebox is an optional add-on module of ArtiPad I, including automotive oscilloscope and automotive ignition waveform. Automotive oscilloscope can make the auto repair technician quickly judge the faults on automotive electronic equipment and wiring, and the oscilloscope sweep speed is far greater than the signal frequency of such vehicles, usually 5-10 times of the measured signal.
ArtiPad I User Manual 12.2 Structure & Accessories 12.2.1 Scopebox structure Fig 12-1 Scopebox Structure Diagram Table 12-1 shows the ports and indicators for the Scopebox. Name Description Generate a square signal with fixed 1K Fixed signal generator frequency. Channel 1...
ArtiPad I User Manual It remains steady green after the Scopebox Running indicator is running. It keeps steady red after the Scopebox is Power indicator powered on. 12.2.2 Scopebox accessories The Scopebox includes the secondary pickup cable for 4-channel oscilloscope, crocodile clips for 4-channel oscilloscope, etc.
12.3 Connection & Initial Use 12.3.1 Connection The Scopebox should work with the ArtiPad I tablet. 1. Firstly, power on the ArtiPad I tablet. 2. Then plug one end of ground cable of the Scopebox into external trigger channel (GND), and the other end should be grounded.
ArtiPad I User Manual Descriptions Signal display area Horizontal Settings: Controls the time base. Vertical Settings: Controls the amplitude of the displayed signal. Trigger Settings: Controls the start event of the sweep. Channel Selection Button Function Menu [Auto]: It indicates auto trigger setting.
Page 96
ArtiPad I User Manual Fig. 12-3 <2> Channel attributes & trigger setting Channel attributes can be set via horizontal settings and vertical settings. Horizontal Settings User can make some settings directly by tapping < or > next to options. Fig. 12-4...
Page 97
ArtiPad I User Manual blank screens into meaningful waveforms. When the Scopebox starts to acquire a waveform, it collects enough data so that it can draw the waveform to the left of the trigger point. The Scopebox continues to acquire data while waiting for the trigger condition to occur. After it detects a trigger, the Scopebox continues to acquire enough data so that it can draw the waveform to the right of the trigger point.
Page 98
ArtiPad I User Manual display noise. OFF: Get full bandwidth. Invert ON: Turn on the invert function. OFF: Restore to the original display of the waveform. Trigger setting Trigger indicates that when certain waveform meets the conditions that are predefined according to the requirements, the Scopebox acquires the waveform and its adjacent section, and then presents it on the screen.
Page 99
ArtiPad I User Manual the Scopebox keeps waiting, and the previous waveform, if any, will remain on the display. Single: In this mode, it only acquires the waveform that generates for the first time the trigger conditions are met, and then stops after finishing capture.
ArtiPad I User Manual Pulse Width Set required pulse width. High Freq Reject high frequency signals when selected. Rejection 12.4.2 Auto The Scopebox has an Auto feature that sets up the Scopebox automatically to display the input signal in a best fit.
ArtiPad I User Manual Moreover, calibration may take several minutes and please be patient to wait. <2> REF settings Reference waveforms are saved waveforms to be selected for display. The reference function will be available after saving the selected waveform to non-volatile memory.
Page 102
ArtiPad I User Manual Fig. 12-10 <2> Horizontal / Vertical measure Horizontal Measure / Vertical Measure are used to measure voltage parameter and time parameter respectively. Drag A line upwards or downwards to control voltage. Move A line left or right to fine-tune timebase. A line is a solid line and B line is a dotted line.
ArtiPad I User Manual 12.4.5 File management <1> Save snapshot While viewing sampling data, tap and then [Save Snapshot] to store the current screen. <2> Snapshot manager While viewing sampling data, tap and then [Snapshot Manager] to enter. View, delete and edit operations are supported.
ArtiPad I User Manual Fig. 12-13 Select the file first, and then tap to open the waveform file. Tap starting the playback and tap to stop it. Fig. 12-14 To delete the waveform file, tap to return to the previous screen.
Page 105
ArtiPad I User Manual Fig. 12-15 and then [Expert Reference] to enter, the following operation can be done: : To load and recall the selected file. : To delete the selected file. : To edit the selected file. <2> Base Reference Preset waveforms of some sensors are available for your reference.
ArtiPad I can test and analyze the secondary signal for various engine ignition systems. 13.1 Secondary-distributor ignition analysis...
Page 107
ArtiPad I User Manual Four-stroke in-line six-cylinder: 1-5-3-6-2-4, or 1-4-2-6-3-5 Four-stroke in-line eight-cylinder: 1-8-4-3-6-5-7-2 Five-cylinder: 1-2-4-5-3 V 6 engine: generally speaking, based on the person sitting on the driver cab, if the right side cylinder numbers on the right side, from the front to the back are as follows: 1, 3, 5;...
ArtiPad I User Manual voltage was sensed and increased sharply 2) Ignition voltage: secondary coil voltage overcome the damper of high voltage line, the contact breaker gap and the spark plug gap to release magnetizing energy, 1-2 section is the breakdown voltage...
Page 109
ArtiPad I User Manual Fig. 13-2 Fig. 13-3 below shows the valid and invalid ignition waveforms. Under the working status of valid ignition, the breakdown voltage and spark voltage are higher because the cylinder is filled with fresh combustible mixture gas, which has a lower ionization level and vice versa.
ArtiPad I User Manual 13.3 Secondary-direct ignition analysis Connection: 1) When the high-voltage wire is exposed, plug the BNC end of secondary ignition pickup into CH1/CH2/CH3/CH4 channel of Scopebox, then connect the high-voltage clip to high-voltage line, and crocodile clips to ground.
ArtiPad I User Manual voltage line as a result of induction of ignition coil. Fig. 13-5 13.4 Waveform analysis mode The ignition secondary single-cylinder waveform test is mainly used to: a. Analyze the ignition dwell angle of single cylinder.(ignition coil charging time) b.
Page 112
ArtiPad I User Manual Test methods and conditions: Start the engine or drive the vehicle accroding to the driving performance fault or poor ignition, etc. Confirm the consistence of judgement standard (the amplitude, frequency, shape and pulse width, etc., for each cylinder), check the fault of the waveform for corresponding components.
Page 113
ArtiPad I User Manual analysis, the related components and mechanical equipment status of ignition system electrical circuit can be analyzed, which provides a reliable basis for the adjustment and maintenance of power circuit to avoid the blind demolition. The waveform shown on Fig. 13-6, appears a lot of clutter on the contact break point, which is obviously caused by the serious erosion on contact break point.
Page 114
ArtiPad I User Manual magnetizing period, which is caused by too large contact gap. Fig. 13-9 A lot of clutter will be displayed on the horizontal section of primary waveform if contact has poor grounding, as shown below figure 13-10.
Page 115
ArtiPad I User Manual secondary faulty waveform for reference. Since various factors lead to the failures, Fig. 13-12 just shows the major possible factors for the failures.
ArtiPad I User Manual 14 Personal Center This function allows users to manage personal information and VCI connector. 14.1 My Report This option is used to view, delete or share the saved reports. Tap “My Report”, there are total 3 options available.
Page 118
ArtiPad I User Manual Fig. 14-2 Tap the desired one to enter: Fig. 14-3 Select the desired data stream items and tap “Confirm” to jump to the playback page:...
Once you choose the connector that belongs to other account, you have to log out, and then input the right account to continue. 14.3 Diagnostic Connector Connection Management This option is used for ArtiPad I to deactivate pairing up with the VCI connector via Bluetooth.
ArtiPad I User Manual Fig. 14-5 * Note: please be sure to keep the VCI connector powered on while performing the operation. 14.4 Activate Connector This item lets you to activate a new VCI connector. Fig. 15-6 Input the Serial Number and Activation Code, and then tap “Activate” to activate the connector.
ArtiPad I User Manual 14.5 Firmware Fix Use this item to upgrade and fix diagnostic firmware. During fixing, please do not cut power or switch to other interfaces. 14.6 Profile Use this item to view and configure personal information. Fig. 14-7 •...
Information” box every time you save the diagnostic report. 15.3 Printer Set This option is designed to establish a wireless connection between ArtiPad I and the Wi-Fi printer (sold separately) while performing printing operations. Follow the steps below to connect the printer.
Page 123
ArtiPad I User Manual Fig. 15-2 A. If it is the first time you have operated this printer, please proceed the following: 2. For initial use, you are suggested to reset the printer: Press and hold [MODE] & [FEED] for 8 seconds, the following resetting command will be printed out:...
ArtiPad I User Manual Step 1: Connect the printer: Tap “Scan” to start scanning and select the desired printer hotspot named with X-431PRINTER-XXXX (XXXX stands for 4 characters), and then tap “Connect” to enter Step 2. Step 2: Join the Wi-Fi printer into LAN: Tap “Scan”...
ArtiPad I User Manual 16 Others 16.1 Email The function allows you to send and receive email. 16.1.1 Configure an email account Note: Before sending or receiving email, you have to set up an email account. In addition, this function required a stable network connection.
To configure it, tap Settings -> Security, and then slide the Unknown sources switch to off. 16.3 Synchronization You can transfer media files and APK between the PC and ArtiPad I. 16.3.1 Connect to PC 1. Use the USB cable to connect the ArtiPad I to your PC.
3. Set the tool as “Connected as a media device”, and copy the APK file from the PC to the tool. 16.4 Clear Cache Doing so clears all browsing records and accounts and enables ArtiPad I to run smoothly and quickly. 1. Tap Settings -> Apps.
“Uninstall”). If all steps mentioned above are finished and the system still works slowly. Please try to close the system and reboot your ArtiPad I. 4. How to reset ArtiPad I? Resetting may cause data loss. Before doing so, please make sure important data and information has been backed up.
Page 129
7. How to pair the VCI connector with the ArtiPad I handset? Users can pair the VCI connector with the ArtiPad I handset via Bluetooth when testing the vehicle or in system settings.
Page 130
2. On the home screen, tap Settings -> Ethernet, and slide the switch to On. B. Connect to a Wi-Fi network ArtiPad I has built-in Wi-Fi that can be used to get online. Once you’re online, you can register your ArtiPad I, browse the Internet, get and update apps and send email on your network.
Page 131
10. The data and time of ArtiPad I can not be set. It is because Automatic date & time is set on your ArtiPad I. Tap Settings > Date & time, deselect “Automatic date & time” and then set the date and time...
Page 132
The exclusive remedy for any automotive meter found to be defective is repair or replacement, and TOPDON shall not be liable for any consequential or incidental damages.
Page 133
Statement: We reserve the rights to make any change to product designs and specifications without notice. The actual object may differ a little from the descriptions in the manual in physical appearance, color and configuration. We have tried our best to make the descriptions and illustrations in the manual as accurate as possible, and defects are inevitable, if you have any question, please contact local dealer or after-sale service center.
Need help?
Do you have a question about the ArtiPad I and is the answer not in the manual?
Questions and answers