Vaillant auroTHERM VFK 145/2 H Installation Manual page 35

Multi-row in-roof mounting
Table of Contents

Advertisement

Fig. 5.35 Riveting the frame
Fig. 5.36 Covering the profile ends with tile supports
Fig. 5.37 Fitting the end caps
Installation manual auroTHERM 0020100606_02
2
1
> Drill a 4.5 mm diameter hole through the
markings in each of the left and right
hand ridge plates into the side sec-
tions (1).
> Rivet the ridge plates to the side sec-
tions (2).
> Lay the tile supports (¬ Table 5.1/5.3,
Item 12) on the ridge plates.
> Bend the metal bands and hook the tile
bars to the roof batten above.
> Cover the side profile ends and the collec-
tor joints from below with the end caps
(¬ Table 5.1/5.3, Item 32).
> To do this, attach the end caps at the bot-
tom.
> Then tilt the end caps upwards until they
can be felt engaging on the upper edge of
the collectors.
Assembly 5
35

Hide quick links:

Advertisement

Table of Contents
loading