Vaillant auroTHERM VFK 145/2 H Installation Manual page 14

Multi-row in-roof mounting
Table of Contents

Advertisement

5 Assembly
Item
Description
1
Collector
2
Upper supply (with probe)
3
Return (inlet)
4
Plug (with vent)
5
Clip
6
Pipe coupling
10
Centre ridge plate
11
Upper ridge plate coupling
12
Tile support
13
Additional roof batten
14
Left ridge plate
15
Right ridge plate
16
Lower ridge plate coupling
Flexible easyform apron
17
(can be ordered as option)
18
Support board
19
Left hand horizontal intermediate plate
20
Right hand horizontal intermediate plate
21
Centre horizontal intermediate plate
22
Upper left shorter side section
23
Upper right shorter side section
24
Lower left longer side section
25
Lower right longer side section
26
Spacer
27
Trapezoidal plate
28
Vertical intermediate plate
29
Clamp
30
Screw kits (Nos. 1-4)
31
Bracket
32
End cap
33
Left hand front section
34
Centre front section
35
Right hand front section
Table 5.1 Kit for vertical collector (VFK 145/2/155 V)
14
Collector array packaging
You require one hydraulic installation set for each collec-
tor row and one hydraulic expansion set for each collec-
tor per row.
Note on additional roof battens (Item 13)
The installation kit contains additional roof battens.
However, the additional battens that you use during
installation must be neither thicker nor thinner than the
existing ones.
> If the additional roof battens in the installation kit
have differing dimensions from the existing roof bat-
tens, battens that are identical to the existing ones
should be provided locally.
Screw kits (Nos. 1 - 4) (Item 30)
The screw kits contain the following screws:
4
Fig. 5.4 Material supplied in screw kits
¬
Screw No.
Used with
1
11, 10, 14, 15, 33, 34, 35
4.5 x 25 mm
2
31, 26, 29, 16, 18
5 x 30 mm
3
13
5 x 70 mm
4
11
M5 x 25/A2
Table 5.2 Screw usage
Installation manual auroTHERM 0020100606_02
3
2
item number in Table 5.1
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents