WATER PIPING - MIXING VALVE USAGE

Mixing Valves

DANGER
HOT
HOT
BURN
Water heated to a temperature which satisfies space
heating, clothes washing, dish washing, and other
sanitizing needs can scald and cause permanent injury
upon contact. Short repeated heating cycles caused by
small hot-water uses can cause a temperature increase of
the hot water by 20F° higher than the heater's temperature
settings.
SUGGESTED PIPING
ARRANGEMENT FOR
SIDE CONNECTIONS
COLD-WATER
INLET
TEMPERATURE-
PRESSURE
RELIEF VALVE
DISCHARGE
PIPE (DO NOT
CAP OR PLUG)
DRAIN
VALVE
MASSACHUSETTS: INSTALL A VACUUM RELIEF IN COLD WATER LINE
PER SECTION 19 MGL 142.
Figure 8.
100221773_2000189439_Rev. 01
Water temperature over
125°F can cause severe
burns instantly resulting in
severe injury or death.
Children, the elderly and the
disabled and are at highest
risk of scald injury.
Feel water before bathing or
showering.
Temperature limiting devices
such as mixing valves must
be installed when required
by codes and to ensure safe
temperatures at fixtures.
SHUT-OFF
TEMPERED
VALVE
POTABLE WATER
MIXING VALVE
CERTAIN
MODELS ARE
EQUIPPED WITH
SIDE PLUMBING
CONNECTIONS
FOR SPACE
HEATING.
* NOTE: THE
T&P VALVE
DISCHARGE
PIPE SHALL
BE PIPED
DIRECTLY TO
THE DRAIN
OR EXTERNAL
TO THE
BUILDING
METAL DRAIN
PAN 1.75 in.
MAX. DEPTH.
AT LEAST 2 in.
GREATER THAN
THE DIAMETER
OF THE WATER
HEATER.
6 in. MAX.
AIR GAP*
This appliance has been design certified as complying
with American National Standard/CSA Standard for water
heaters and certain models with side plumbing connections
are considered suitable for Water (Potable) Heating and
Space Heating.
Note: Do not use in space heating only applications.
The water supply pressure should not exceed 80 psi. If this
occurs, a pressure reducing valve with a bypass should be
installed in the cold water inlet line. This should be placed
on the supply to the entire house in order to maintain equal
hot and cold water pressures.
SUGGESTED PIPING
ARRANGEMENT FOR
TOP CONNECTIONS
COLD-WATER
INLET
NON-TEMPERED
WATER RETURN
TEMPERATURE-
PRESSURE
RELIEF VALVE
* NOTE: THE
T&P VALVE
DISCHARGE
PIPE SHALL
BE PIPED
DIRECTLY TO
THE DRAIN
OR EXTERNAL
TO THE
BUILDING
DISCHARGE
PIPE (DO NOT
CAP OR PLUG)
DRAIN
VALVE
TEMPERED
POTABLE
WATER
NON-
TEMPERED
WATER
SUPPLY
TO HOT
OUTLET
www. lochinvar .com
SHUT-OFF
TEMPERED
VALVE
POTABLE WATER
NON-TEMPERED
WATER SUPPLY
MIXING VALVE
MASSACHUSETTS:
INSTALL A VACUUM
RELIEF IN COLD
WATER LINE PER
SECTION 19 MGL
142.
GREATER THAN
THE DIAMETER
OF THE WATER
Figure 9.
SHUT-OFF
VALVE
MIXING
VALVE
TEMPERED
Figure 10.
METAL DRAIN
PAN 1.75 in.
MAX. DEPTH.
AT LEAST 2 in.
HEATER.
6 in. MAX.
AIR GAP*
COLD-
WATER
SUPPLY
NON-
WATER
RETURN
TO COLD
INLET
11