Download Print this page
Sebo Essential G Owner's Manual
Hide thumbs Also See for Essential G:

Advertisement

Quick Links

SEBO Essential G Owner's Manual
Owner's Manual for the SEBO Essential G Vacuum
Technical Details
Clog Removal
Maintenance
Vacuum Motor - 1300 watts - 10.8 amps
Filter bag capacity - 1.4 gal
120v AC - 50-60Hz
Brush speed - 3100rpm
READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE
When using an electrical appliance, basic precautions must always be followed.
To reduce the risk of electric shock, this brush machine has a polarized plug; one blade is wider than the
other. This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not
change the plug in any way. Connect only to the outlet type specified on the serial number plate
underneath the machine.
WARNING: To reduce the risk of fire, electric shock, or injury:
Do not leave brush machine while plugged in. Unplug from outlet when not in use and before servicing.
Do not use outdoors or on wet surfaces.
Do not use near small children or pets. Do not allow to be used as a toy. Use of this product by children should always be
supervised by an adult.
Use only as described in this manual. Use only manufacturer-recommended attachments.
Do not use with a damaged cord or plug. If brush machine is not working as it should, has been dropped, damaged, left outdoors,
or dropped into water, take it to a SEBO service center.
Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Do not run
machine over cord. Keep cord away from heated surfaces.
Do not unplug by pulling on cord. To unplug, grasp the plug � not the cord.
Do not plug in if switch is in the �I� (ON) position.
Do not use outlets above counters to plug in brush machine � damage to items in the surrounding area could occur.
Always carry the machine over steps and sills.
Do not handle plug or vacuum handle with wet hands.
Do not put any object into machine openings. Do not use machine with any openings blocked. Keep openings free of lint, hair,
and anything that may reduce air flow.
Do not re-use filter (dust) bags or wash the filters.
Do not remove any screws from vacuum.
Do not run machine over anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
Do not use vacuum without dust bag and/or filters in place.
Turn off all machine controls before unplugging.
Use extra care when cleaning on stairs.
Do not use machine to clean up flammable or combustible liquids such as gasoline or use in areas where they may be present.
Machines can cause a fire when operated near flammable vapors or materials. Do not operate this machine near flammable fluids,
dust or vapors.
Maintenance and repairs must be done by qualified personnel.
Use only original SEBO replacement parts.
Table of Contents
Important Safety Instructions
Assembly
Troubleshooting Guide
Technical Details
Water lift at motor - 92.5in
Sound level - 69 dB
Working width - G1-12" | G2-15"
Floor adjustment - manual
Important Safety Instructions
SAVE THESE INSTRUCTIONS.
Sebo duo Carpet Cleaning
System Product Features
Operating Instructions
Schematic and
Part Numbers
Airflow at motor - 103.8 CFM
Body weight:
G1 (16.9lbs) | G2 (17.1 lbs)
Brush Drive - toothed belt
Cord length - 40ft
Identification of Parts
How to Use the
Duo Cleaning System
Warranty Information

Advertisement

loading
Need help?

Need help?

Do you have a question about the Essential G and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sebo Essential G

  • Page 1  Do not use with a damaged cord or plug. If brush machine is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, take it to a SEBO service center.  Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Do not run machine over cord.
  • Page 2 Any other servicing should be performed by an authorized service representative. Special Product Features Your SEBO essential G series vacuum cleaner is the most technically advanced upright vacuum cleaner in the world. Along with its excellent filtration system (99.9% to 0.3 microns), the machine has warning systems and automatic shut-off capabilities that are designed to alert the user to machine problems that, if ignored, will damage the machine or diminish performance.
  • Page 3 5. Bag Full or Clog Warning Auto Shut-Off. If the vacuum�s air flow pathway becomes restricted due to a full bag or the existence of a clog, the red �BAG FULL OR CLOG� light located on top of the power head will illuminate. If the user ignores this warning for approximately 30 seconds, the machine will shut off and the �BAG FULL OR CLOG�...
  • Page 4 When possible, consult the materials supplied by your floor�s manufacturer for information on proper upkeep and cleaning. To ensure that your new SEBO vacuum cleaner is compatible with your floor, please test the vacuum cleaner on each type of flooring surface in a small inconspicuous area to determine if any damage occurs.
  • Page 5 To vacuum walls, under beds, or higher-reach areas, etc., the SEBO essential G can be fitted with an additional straight tube (45) and the wall and floor brush (41). The machine will then perform as a canister vacuum (as shown in figure 3).
  • Page 6 Maintenance Always unplug vacuum from outlet before dismantling any part of the machine! Changing the Dust Bag -Figure 9 To change the dust bag, pull the cover release flap forward (#5 on page 5) and lift the cover (7) from the dust bag housing. The cover release flap must remain in a for- ward �pulled-out�...
  • Page 7 Clog Removal Always unplug vacuum from outlet before removing any clogs! Clogs in the Airflow Pathway -Figure 13 Most clogs can be removed by accessing the airflow pathway via the orange colored access door (39) located on the underside of the power head. However, other clogs may only be removed by accessing the airflow pathway by disassembling the machine in the opposite sequence of the machine�s original assembly (see assembly, page 5).
  • Page 8 Troubleshooting Guide Always unplug brush machine from outlet before dismantling any part of the machine! Problem Reason(s) Solution Handle not fully inserted into the Release handle catch, push handle housing, causing a faulty connection down, close handle catch Does not turn Not plugged into good outlet.
  • Page 9 3. Sebo America or an authorized Sebo dealer must complete all warranty repairs. 4. To locate an authorized Sebo dealer in your area, or to register a warranty claim in the United States of America, please visit www.sebo.us 5.
  • Page 10 Sebo will not be liable for incidental or consequential damages of any kind or nature. This disclaimer of implied warranties shall not apply to the extent said disclaimer is not allowed by applicable state/provincial law. To contact Sebo in the United States:...