Instruction Manual
Plug in Digital Time Switch
Safety precautions
· The connection and installation of electrical devices may
only be carried out by a qualified electrician.
· Interventions in and changes to the device result in the
voiding of the warranty claim.
· Observe your national regulations and the respective
safety provisions.
· Switch-off commands have priority over switch-on com-
mands.
Menu
Prog
Setting of this programmable timer is depending of the
user preference to use pre-set programs or defining own
programming.
Using Pre-set programs (first time installation)
+
-
Res.
Menu OK
RND
+1h
Using Reset key you can adjust the following values:
· 24h or am/pm
· Time (hour and minutes)
· Week day
· Pre-set programs P01 to P03
User defined programming by Menu mode
+
-
Res.
Menu OK
RND
+1h
Using Menu key you can adjust / review the following
values:
· 24h or am/pm
· Time (hour and minutes)
· Week day
· Programs P--
OK
reset
: Overview of daily switching program
: Setting of 24h or am/pm
: Summer/winter clock changes
: Weekday display
: Switching status display ON/OFF
: Manual operation / fixed ON / fixed OFF
: Automatic operation
+/-
: Adjustment keys:
By pressing the key longer than 2 sec. you
can adjust the timer in steps of 5 units
Res.
: Reset
Menu : By pressing the menu key programming
is terminated and the system reverts to
automatic operation
OK
: Confirmation of programming
RND
: Random function
Sequence to follow after selecting programming by pre-set
Set minutes
programs or Menu mode.
Set display format 24h or am/pm
14
16
1
2
18
3
4
20
5
22
6
7
24
1
1
2
+
-
Res.
Menu OK
Select minutes (+/-) and confirm with OK.
RND
+1h
Set week day
Select 24h or am/pm (+/-) and confirm with OK.
Set hour
14
16
1
2
18
3
4
20
5
6
22
7
24
1
1
2
+
-
Res.
Menu OK
Select week day (+/-) and confirm with OK.
RND
+1h
1 = Monday
2 = Tuesday
Select hour (+/-) and confirm with OK.
3 = Wednesday
4 = Thursday
Technical Data
Supply voltage
Switching capacity
14
Ambient temperature
16
Protection class
1
2
18
3
Accuracy
4
20
Reserve power
5
22
6
Shortest switching time
7
24
Memory spaces
+
-
Res.
Menu OK
RND
+1h
Prog.
Programs P01-03
The switching on and off times for programs P01 to P03
are preset (pre).
The user can change these programs.
14
16
1
P01: Mo - Su, 1 x ON/OFF
2
18
3
4
20
5
22
6
7
24
0
6
P02: Mo - Su, 2 x ON/OFF
1
1
2
ON
+
-
Res.
Menu OK
0
7
12
RND
+1h
P03: Mo - Su, 3 x ON/OFF
ON
0
7
12
14
16
1
Individual program, P--
2
18
3
Under the menu option P-- you have the option of creating
4
20
5
a user-defined program.
22
6
7
This program can be changed at any time. There are up
24
to 20 memory locations available for 10 OFF and 10 ON
commands.
You can allocate a corresponding weekday or week block
to each memory location.
1
1
2
+
-
Res.
Menu OK
RND
+1h
5 = Friday
6 = Saturday
7 = Sunday
P0x
prog
Selecting pre-set programs P01 to P03
see inprint on device
see inprint on device
Sequence to follow after setting time in the Reset mode.
-10ºC to +55ºC
IP 51 electronic
IP 20 terminal box
+/- 1/sec day at 20ºC
3 years from factory at
1
2
+20ºC
3
4
1 min
5
6
20
7
1
1
+
-
Res.
Menu OK
RND
+1h
Select pre-set program (+/-).
1
2
3
4
5
6
7
ON
1a
22
24
+
-
Res.
Menu OK
RND
+1h
14
20
24
1
2
3
4
5
6
7
14
18
20
22
24
Once selected the program desired there are following
options:
Menu
terminate programming
OK
Going through pre-set programs to modify selection (any
program ON or OFF can be modified by using ''+'' or ''-''
keys and confirming with OK) or accept it with OK key to
go to the next free memory location in order to add new
e.g. after selecting P02 you should also program:
Sa-Su 22:30 ON (prog05)
23:00 OFF (prog06)
14
16
18
20
22
24
14
16
18
20
22
24
1b
14
16
18
20
22
24
Need help?