Installing Optional Catalyst - Vermont Castings 2115 Installation Manual

Hide thumbs Also See for 2115:
Table of Contents

Advertisement

Figure 5.5 - Assemble the front door handle.
Storing the Handle
Use the removable handle to open or close the doors. After
using it, remove the handle so it will not get hot. Store the
ST540
handle in the handle holder installed behind the right front
Assembly
leg. (Figure 5.5)
handle
11/00
Handle
Handle
Holder
Figure 5.5 - Handle holder and heat shield positions.
C. Installing Optional Catalyst
1. Locate the access cover positioned at the rear center of
the unit. (Figure 5.6)
2. Remove the access cover by pulling straight up and out.
(Figure 5.7)
3. Install the catalyst by gently placing it into the cavity and
straight down, (Figure 5.8). Place the catalyst where the
catalyst's ceramic components will not be damaged.
Access Cover
Figure 5.6 - Locate access cover.
18
Shield
Position
(Part
#30007430)
Vermont Castings • Intrepid FlexBurn
Remove
Access Cover
Figure 5.7 - Remove access cover.
Catalyst Installed
Figure 5.8 - Remove catalyst.
Attach the Catalyst Temperature Probe
If the catalytic performance pack has been purchased, install
the catalyst temperature probe into the cast iron wall behind
the rear shield as shown (Figure 5.9) use two #10 sheet metal
screws and bracket supplied, secure the bracket and probe
to the back of your stove. (Figure 5.9)
1.4"
Fold bracket strap over
catalyst probe shaft
and secure with screw.
Insert catalyst probe
through sheet-metal and
cast iron back and twist &
push through fiber panel.
Figure 5.9 - Install the Catalyst Temperature Probe
Installation Manual_R2 • 2018 - ___ • 07/18
®
Bracket mounting screw hole location
1.8"
Insert catalyst probe bracket
with self-drilling screw.
3-90-30007345i