Axis T90B35 W-LED Installation Manual

Axis t90b series
Hide thumbs Also See for AXIS T90B35 W-LED:

Advertisement

Quick Links

AXIS T90B Series
AXIS T90B15 W-LED
AXIS T90B25 W-LED
AXIS T90B35 W-LED
AXIS T90B20 IR-LED
AXIS T90B30 IR-LED
AXIS T90B40 IR-LED
Installation Guide

Advertisement

Table of Contents
loading

Summary of Contents for Axis AXIS T90B35 W-LED

  • Page 1 AXIS T90B Series AXIS T90B15 W-LED AXIS T90B25 W-LED AXIS T90B35 W-LED AXIS T90B20 IR-LED AXIS T90B30 IR-LED AXIS T90B40 IR-LED Installation Guide...
  • Page 2: Electromagnetic Compatibility (Emc)

    Legal Considerations A copy of the original declaration of conformity may be obtained from Axis Communications ABn See Video and audio surveillance can be regulated by Contact Information on pase 3 n laws that vary from country to countryn Check the...
  • Page 3: Contact Information

    Support groundedn Should you require any technical assistance, please Korea contact your Axis resellern If your questions cannot 이 기기는 가정용(B급) 전자파적합기기로서 be answered immediately, your reseller will forward 주로 가정에서 사용하는 것을 목적으로 하며, your queries through the appropriate channels to 모든...
  • Page 5: Safety Information

    AXIS T90B Series Safety Information Read through this Installation Guide carefully before installing the productn Keep the Installation Guide for future referencen Hazard Levels Indicates a hazardous situation which, if not DANGER avoided, will result in death or serious injuryn...
  • Page 6: Safety Instructions

    NO TICi TICi TICi • The Axis product shall be used in compliance with local laws and regulationsn • Store the Axis product in a dry and ventilated environmentn • Avoid exposing the Axis product to shocks or heavy pressuren •...
  • Page 7: Installation Steps

    AXIS T90B Series Installation Guide This Installation Guide provides instructions for installing AXIS T90B Seriesn Installation Steps Make sure the package contents, tools and other materials necessary for the installation are in ordern See pase 7 n Study the hardware overviewn See pase 8 n...
  • Page 8: Hardware Overview

    AXIS T90B Series Hardware Overview Illuminator Photocell Cable Breather sland...
  • Page 9 AXIS T90B Series Power cable (red) Power cable (black) Photocell cable (white) Photocell cable (cellow) Telemetrc cable (purple) Telemetrc cable (oranse)
  • Page 10 AXIS T90B Series Red LiD indicator Amber LiD indicator Green LiD indicator Remote control receiver Mountins bracket (pre-mounted)
  • Page 11 AXIS T90B Series AXIS T90B40 IR-LED Cables Mountins bracket (pre-mounted) Bolt Optional Accessories Remote Control For information how to use the remote control, see Access the Productn...
  • Page 12 Photocell disable button DIM button RiSiT button STATUS button Disable remote control setup button TiLiMiTRY button Mounting Brackets To install the product using a compatible bracket from AXIS T90B Mounting Accessories, see the Installation Guide delivered separately with the mounting bracketn...
  • Page 13 AXIS T90B Series LED Indicators There are three colored LED indicators on the base of the illuminator which provide operating and status informationn The color status depends on the current operating mode: • Programming Mode • Normal Operating Mode Prosrammins Mode...
  • Page 14: Specifications

    AXIS T90B Series Normal Operatins Mode (Continued) Solid Amber Input voltage level error* Solid Red Internal LED error *Once the voltage error has been corrected, disable the remote control setup or restart the illuminator to turn the status LED offn...
  • Page 15: Install The Hardware

    12–24 V AC/DC, max 96 W For more information about power consumption, see Technical Specifications on pase 29 Install the Hardware To install the product using a compatible bracket from AXIS T90B Mounting Accessories, see the Installation Guide delivered separately with the mounting bracketn...
  • Page 16 AXIS T90B Series CAUTION IR emitted from this productn Avoid prolonged eye exposure or use appropriate shielding or eye protection at distances of less than 1n5 mn Follow these installation procedures: If required, remove the screws and move the standard bracket to the top of the illuminatorn If required, loosen the screws and turn the bracket 90°n...
  • Page 17 AXIS T90B Series If required, loosen the screws and change to a diverging lens with the desired angle of illuminationn The angle of illumination should be adjusted according to the camera field of view to light the whole scene adequatelyn See Technical...
  • Page 18 AXIS T90B Series Screws Diversins lens Note Adjust the vertical position of the illuminator to ensure that the field of view of the camera is illuminatedn...
  • Page 19 AXIS T90B Series Position the illuminator adjacent to the camera and point the illuminator towards the scenen CAUTION Red cable = +ve, Black cable = -ve (polarity sensitive) Mount the power supplyn Connect the illuminator to the power supplyn...
  • Page 20: Access The Product

    AXIS T90B Series Illuminator Power cable Power supplc Set photocell following output (White & Yellow) Volt free output — normally open (day) to normally closed (night)n Connect direct to camera if required to control switchover of day/night camerasn Access the Product...
  • Page 21: Normal Operating Mode

    AXIS T90B Series • Telemetry TEL enabled • Telemetry input wires soldered together for automatic photocell operation • Telemetry DIM disabled • LED status indicators enabled • Programming Mode Note Changing the settings requires a remote control (optional accessory)n The illuminator must be in Programming Moden...
  • Page 22: Power Adjust

    AXIS T90B Series Power Adjust The power output of the illuminator can be adjusted between five pre-set levelsn Select the required light intensity by using the buttons belown 20% of maximum 40% of maximum 60% of maximum 80% of maximum...
  • Page 23: Telemetry Input

    AXIS T90B Series There are three pre-defined levels to set the lux level threshold at which the photocell turns the illuminator on or offn Select the required sensitivity level by using the buttons belown Photocell disabled 5 Lux On, 15 Lux Off...
  • Page 24 AXIS T90B Series Non polarity sensitive Volt-free input: Short circuit = Light on TTL input: Orange = TTL +ve Purple = TTL -ve (GND) 0 V = Light on 3 V = Light off The telemetry input wires (orange and purple) are soldered together...
  • Page 25 AXIS T90B Series Turn the light on (night) and off (day) automatically via the photocelln This is the standard factory setting, no further action is requiredn Turn the light on and off from a remote switch or inputn Used in conjunction with the Timer Function to turn the light...
  • Page 26: Led Status Indicators

    AXIS T90B Series If you wish to cancel the timer period and have the illuminator operate under standard telemetry conditions, press Timer Disabledn Timer disabled 1 minute 3 minutes 10 minutes 30 minutes TiL button LED Status Indicators This status indicator function can be switched on and off by pressing the...
  • Page 27: Factory Default

    AXIS T90B Series Factory Default Note To activate this feature the button must be pressed continuously for 4 secondsn This is to avoid the possibility of activating this feature accidentallyn Once the illuminator has been programmed, the settings will be stored in a...
  • Page 28 AXIS T90B Series • Basics Check the LED status indicatorn See LiD Indicatorsn Check polarity of lamp connection: red = +ve, black = -ve Ensure power is 12-24 V AC or DC Ensure telemetry wires are shorted out or closed...
  • Page 29: Technical Specifications

    Check the remote control batteryn Technical Specifications Models AXIS T90B15 W-LED AXIS T90B25 W-LED AXIS T90B35 W-LED AXIS T90B20 IR-LED AXIS T90B30 IR-LED AXIS T90B40 IR-LED IR-LED: All Axis cameras with IR cut filter Supported cameras W-LED: All Axis network cameras...
  • Page 30 AXIS T90B15 W-LED: 12 W / 3 W / 0n15 W AXIS T90B25 W-LED: 24 W / 6 W / 0n15 W AXIS T90B35 W-LED: 48 W / 12 W / 0n15 W AXIS T90B20 IR-LED: 24 W / 6 W / 0n15 W...
  • Page 31 35°x10° - 55 m (180 ft) 60°x25° - 30 m (98 ft) 80°x30° - 20 m (66 ft) 120°x50° - 15 m (49 ft)** AXIS T90B35 W-LED 10°x10° - 150 m (492 ft)* 35°x10° - 80 m (262 ft) 60°x25° - 45 m (148 ft)
  • Page 32 AXIS T90B Series 80°x30° - 30 m (98 ft) 120°x50° - 20 m (66 ft)** *No diverging lens **Optional accessory Casing Material: Polycarbonate IR-LED: Black W-LED: White and silver Display and indicators LED indicators Environment Outdoor Mounting Wall Ceiling Column...
  • Page 33: Further Information

    AXIS T90B25 W-LED: 100 x 135 x 66 mm (4 x 5 x 2n5 in) AXIS T90B35 W-LED: 135 x 180 x 68,2 mm (5 x 7 x3n2 in) AXIS T90B20 IR-LED: 100 x 135 x 66 mm (4 x...
  • Page 34: Warranty Information

    AXIS T90B Series Warranty Information For information about Axis’ product warranty and thereto related information, see www.axis.com/warrantc/...
  • Page 36 Installation Guide Vern M1n11 Date: May 2014 AXIS T90B Series © Axis Communications AB, 2014 Part Non 57589...

Table of Contents