Tapeswitch GS-120 Technical Manual page 56

Photo-electric light curtain systems
Table of Contents

Advertisement

Release 7/2009 Ver. 1.0
CABLE #
CABLE TYPE
RKT5-612/XX
W1
W1
W1
W1
W1
RKT5-612/XX
W1A
W1A
W1A
W1A
W1A
RKT8-09/XX
W2
W2
W2
W2
W2
W2
W2
W2
RKT8-09/XX
W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A
* Denotes Double Connection
Figure 58 – Wire Run List for the BSRUA-2 TWO Light Curtain Configuration
TAPESWITCH CORPORATION
100 Schmitt Boulevard
Farmingdale, New York 11735
COLOR
FUNCTION
CODE
"
Brown
+24V D.C.
"
White
OV D.C.
"
Blue
Test Out
"
Black
Test In
"
Gray
Ground
"
Brown
+24V D.C.
"
White
OV D.C.
"
Blue
Test Out
"
Black
Test In
"
Gray
Ground
"
White
OV D.C.
"
Brown
24V D.C.
"
Green
Ground
"
Yellow
Output 1
"
Gray
Output 2
"
Pink
Data (-)
"
Blue
Data (+)
"
Shield
Ground
"
White
OV D.C.
"
Brown
24V D.C.
"
Green
Ground
"
Yellow
Output 1
"
Gray
Output 2
"
Pink
Data (-)
"
Blue
Data (+)
"
Shield
Ground
Technical Manual: GS-120 Light Curtain Systems
FROM
Emitter #1
5 Pin Quick Disconnect
1
2
TWIST PAIR TOGETHER
Black and Blue Wire
5
Emitter #2
5 Pin Quick Disconnect
1
2
TWIST PAIR TOGETHER
Black and Blue Wire
5
Receiver #1
8 Pin Quick Disconnect
1
2
3
4
5
6} Isolate 6 & 7
7} Isolate 6 & 7
8
Receiver #2
8 Pin Quick Disconnect
1
2
3
4
5
6} Isolate 6 & 7
7} Isolate 6 & 7
8
56
TO
BSRUA-2
17*
18*
No Connection
No Connection
25, 27, or Ground
BSRUA-2
15*
16*
No Connection
No Connection
25, 27, or Ground
BSRUA-2
18*
17*
25, 27, or Ground
4
5
No Connection
No Connection
25, 27, or Ground
BSRUA-2
16*
15*
25, 27, or Ground
9
14
No Connection
No Connection
25, 27, or Ground
Phone: 631-630-0442
Fax: 631-630-0454
www.tapeswitch.com