Tapeswitch GS-120 Technical Manual page 52

Photo-electric light curtain systems
Table of Contents

Advertisement

Release 7/2009 Ver. 1.0
110VAC: Jumper 29 to 31 and 30 to 32
240VAC: Jumper 30 to 31
For ONE Light Curtain
Jumper 1 to 2, 4 to 9
5 to 14, and 7 to 8 (if not used)
TAPESWITCH CORPORATION
100 Schmitt Boulevard
Farmingdale, New York 11735
DC Input Power
+24V DC
2
OV DC
3
AC Power Input
Live
26
Ground
27
Neutral
28
FOR AC POWER
JUMPERS
Figure 54 - Input and Output Functions, Jumper Details and
Terminal Numbers for the BSRUA-2
Technical Manual: GS-120 Light Curtain Systems
Redundant
Safety Outputs
Test Inputs (if used)
7
8
For TWO Light Curtains
Jumper 1 to 2, 7 to 8 (if not used)
19 to 20 (if not used)
52
24
N/O
Output 1
23
22
N/O
Output 2
21
19
20
Phone: 631-630-0442
Fax: 631-630-0454
www.tapeswitch.com

Advertisement

Table of Contents
loading

Related Products for Tapeswitch GS-120

Table of Contents