Designer-style Hybrid Keypad
120 V~ 50 / 60 Hz
Typical Power Consumption*: 0.75 W
Installation Instructions
Remote Dimmer: RD-RD
Please Read Before Installing
Typical Power Consumption*: 0 W
RRD-H1RLD
RRD-H3BSRL
RRD-H5BRL
RRD-H2RLD
RRD-H4S
RRD-H6BRL
Use these instructions to install the model numbers listed above.
For system Setup Guide and tools visit: www.lutron.com/radiora2
1
Load Type
Minimum Load
Maximum Load
With Neutral
Without Neutral
Incandescent
15 W
50 W
450 W
2
MLV
15 W / VA
50 W / VA
350 W / 450 VA
Load Specifications:
1
Load Type: Hybrid Keypads are designed for use with permanently installed incandescent, magnetic
low-voltage, or tungsten halogen only. To reduce the risk of overheating and possible damage to other
equipment, do not install Hybrid Keypads to control receptacles or motor-operated appliances.
2
Low-Voltage Applications: Use Hybrid Keypads with magnetic (core and coil) low-voltage transformers
only. Not for use with electronic (solid-state) low-voltage transformers. Operation of a low-voltage circuit
with lamps inoperative or removed may result in transformer overheating and premature failure. Lutron
strongly recommends the following:
• Do not operate low-voltage circuits without operative lamps in place.
• Replace burned-out lamps as quickly as possible.
• Use transformers that incorporate thermal protection or fused transformer primary windings to
prevent transformer failure due to overcurrent.
Important Notes
WARNING - Entrapment hazard - To avoid the risk of entrapment,
serious injury, or death, these controls must not be used to control
equipment which is not visible from every control location or which
could create hazardous situations such as entrapment if operated accidentally.
Examples of such equipment which must not be operated by these controls
include (but are not limited to) motorized gates, garage doors, industrial doors,
microwave ovens, heating pads, etc. It is the installer's responsibility to ensure
that the equipment being controlled is visible from every control location and
that only suitable equipment is connected to these controls. Failure to do so
could result in serious injury or death.
Codes: Install in accordance with all local and national electrical codes.
Grounding: When no "grounding means" exist in wallbox, the 2011 National
Electrical CodeR (NECR) allows a control to be installed as a replacement if 1)
a nonmetallic, noncombustible faceplate is used with nonmetallic attachment
screws or 2) the circuit is protected by a ground fault circuit interrupter (GFCI).
When installing a control according to these methods, cap or remove green
wire before screwing control into wallbox.
Neutral Wire: Hybrid Keypads have an available neutral wire terminal that can
be connected to the neutral wire in a wallbox where the Hybrid Keypad is to
be installed. Connecting the neutral wire to a Hybrid Keypad allows a lower
minimum load to be used. Also, normal keypad operation will be available even
if the attached load is not installed or if the lamp is burned out. If a neutral
wire connection is available, connect it to the silver terminal. If a neutral wire
connection is desired but not available in the wallbox, contact a licensed
electrician for installation.
Environment: Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C),
0% to 90% humidity, non-condensing. Indoor use only.
Spacing: If mounting one control above another, leave at least 4 ½ in (114 mm)
vertical space between them.
Wallplates: LutronR ClaroR and Satin ColorsR wallplates are strongly
recommended for best color match and clean aesthetic appearance. Do not
paint keypads, buttons, or wallplates.
Cleaning: To clean, wipe with a clean damp cloth. Do NoT use any chemical
cleaning solutions.
Wallboxes: Lutron recommends using 3 ½ in (89 mm) deep wallboxes for easier
installation. Several controls may be installed in one multigang wallbox.
Remote Dimmers: Use only Remote Dimmers (RD-RD) with Hybrid Keypads.
Up to 9 RD-RD controls may be used with a Hybrid keypad.
RF Device Placement: RF dimmers, switches, keypads and shades / draperies
must be located within 30 ft (9 m) of an RF signal repeater. For systems without
an RF signal repeater, all RF dimmers, switches, keypads and shades / draperies
must be located within 30 ft (9 m) of each other. Remote dimmers and switches
are not required to be within a specific range.
Engraving: The Prepaid Engraving Certificate included with the Hybrid
Keypad can be redeemed for a custom engraved replacement kit. To order a
replacement kit please follow the instructions at: www.lutron.com/buttons
* Typical Power Consumption test conditions: load is off, all backlights on medium intensity, two LEDs on
(two presets active), keypad powered at 120 V
Technical Assistance:
U.S.A. and Canada (24 hrs / 7 days)
Brazil (Monday-Friday 8:30am - 5:30pm BRT)
1.800.523.9466
+55 (11) 3257.6745
Mexico 8am – 8pm ET
Other countries 8am – 8pm ET
+1.888.235.2910
+1.610.282.3800
Lutron Elec tron ics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299
P/N 044-299 Rev. A 10/2011
Multigang Installations
In multigang installations, several controls are grouped horizontally in one
multigang wallbox. When combining controls in a wallbox, derating is required;
however, no derating is required for Remote Dimmers.
Derating Chart
Load Type
End of Gang
Middle of Gang
Incandescent
350 W
250 W
MLV
250 W / 350 VA
200 W / 250 VA
Installation
WARNING - Shock hazard - To avoid the risk of electric shock, locate
and remove fuse or lock circuit breaker in the OFF position before
proceeding. Wiring with power ON could result in serious injury or death.
1. Turn power OFF at fusebox or circuit breaker.
2. Check the installation for short circuits before installing control(s). With power
OFF, install standard mechanical switch(es) between Hot and load. Restore
power. If lights do not work or a breaker trips, check wiring. Correct wiring
and check again. Install control(s) only when short is no longer present.
Warranty is void if keypad is installed in a shorted circuit.
3. Wire keypads according to one of the following options:
a. Terminals:
Trim or strip wallbox wires to the length indicated by the strip gauge on the
back of the keypad.
• Push-In Terminals: Use with 14 AWG (1.5 mm
) solid copper wire
2
only. DO NOT use stranded or twisted wire.
Insert wires fully. To release wire, insert small, flat screwdriver into slot
below push-in terminal. Push screwdriver in while pulling wire out.
OR
• Screw Terminals: use with 12 AWG (2.5 mm
) or 14 AWG (1.5 mm
2
solid copper wire only. DO NOT use stranded or twisted wire.
Wrap wire around screw terminal. Tighten securely to 5 in-lb (0.55 N•m).
b. Wire Connectors:
Prepare wires. When making wire connections, follow the recommended
strip lengths and combinations for the supplied wire connector.
Note: Wire connector provided is suitable for copper wire only.
Wire Connector:
• Strip insulation 3/8 in (10 mm) for 14 AWG (1.5 mm
)
2
or 12 AWG (2.5 mm
) wire
Twist wire
2
connector
• Strip insulation 7/16 in (11 mm) for 18 AWG
tight.
(0.75 mm
) wire
2
• Use to join one or two 14 AWG (1.5 mm
) or 12 AWG
2
(2.5 mm
) wires with one 18 AWG (0.75 mm
) ground wire.
2
2
For installations WITH a neutral wire: See Wiring Diagrams 1a or 1b.
For installations WITHOUT a neutral wire: See Wiring Diagram 2a or 2b.
Note: If a neutral wire connection is available, connect it to the silver terminal.
4. Push all wires back into the wallbox and loosely fasten the Hybrid Keypad to the
wallbox using the control mounting screws provided. Do not pinch the wires.
5. Attach LutronR ClaroR or Satin ColorsR wallplate adapter and wallplate. See
the Mounting Diagram.
a. Install the wallplate adapter onto the front of the Hybrid Keypad.
b. Tighten the keypad mounting screws until wallplate adapter is flush to the
wall (do not over-tighten).
c. Snap the wallplate onto the wallplate adapter and verify that the Hybrid
Keypad is aligned properly.
d. If the Hybrid Keypad is misaligned, remove wallplate and loosen the
mounting screws to adjust the Hybrid Keypad appropriately. When the Hybrid
Keypad is alligned properly, snap the wallplate onto the wallplate adapter.
6. Restore power. Check for correct local operation. See operation.
Lamp Replacement
WARNING - Shock hazard - For any procedure other than routine lamp
replacement, power must be disconnected at the main electrical panel.
Working with power ON could result in serious injury or even death.
For routine lamp replacement, remove power from the fixture(s) by pulling the
FASST switch out on both the Hybrid Keypad and all Remote Dimmers
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. Lutron, Claro, Satin Colors, RadioRA and
Lutron Electronics Co., Inc.
©2011 Lutron Electronics Co., Inc.
Wiring Diagram 1a
Wiring Diagram 2a
1
Single Location Installation with Neutral
Single Location Installation without Neutral
Hybrid Keypad
Brass
Blue
1
Silver
Hot/Live
Hot/Live
Black
Green
Lighting
120 V
120 V
Load
50 / 60 Hz
50 / 60 Hz
Ground
Neutral
Neutral
Wiring Diagram 1b
3, 4
Multi-Location Installation with Neutral
Remote Dimmer
Remote Dimmer
Brass
Blue
Brass
Blue
Hot/Live
Black
Black
Green
Green
120 V
50 / 60 Hz
Ground
Ground
Neutral
Wiring Diagram 2b
2, 3
Multi-Location Installation without Neutral
Remote Dimmer or
Remote Dimmer or
Hybrid Keypad
Hybrid Keypad
Brass
Blue
Brass
Blue
Hot/Live
Black
Black
Green
Green
120 V
50 / 60 Hz
Ground
Ground
)
Neutral
2
1
When using controls in single location installations, tighten the blue terminal without any
wires attached. DO NOT connect the blue terminal to any other wiring or to ground.
2
In installations without a neutral wire connection, tighten the silver terminal without any
wires attached. DO NOT connect the silver terminal to any other wiring or to ground.
3
Up to 9 Remote Dimmers may be connected to the Hybrid Keypad. Total blue terminal
wire length may be up to 250 ft (76 m).
4
Neutral wire Hybrid Keypads must be connected on the load side of a multi-location
installation.
Mounting Diagram
Keypad
Mounting
Screws
Wallbox
Replacement
Kit
Hybrid
Keypad
operation
NOTE: Orientation arrow MUST point UP.
Keypad Buttons
Status LEDs
Press to activate desired levels of lighting or
Show which
positions of shades /draperies.
button
By default, the internal dimmer is controlled by the
has been
top keypad button. Tap to toggle load ON / OFF.
activated.
Raise / Lower Buttons
Lights increase / decrease in intensity and
FASST
shades / draperies raise / lower.
Front
Accessible
Service
Switch
are registered trademarks and RadioRA 2 and FASS are trademarks of
Troubleshooting Guide
1, 2
Symptom
Probable Cause and Action
Hybrid Keypad
Lights do not
Improper programming
Brass
Blue
1
Silver
respond to a
• Program according to the system Setup Guide.
Hybrid Keypad
Black
Green
If the system is GUI programmed, ensure that the load
Lighting
button press
Load
has been assigned to the keypad button in the GUI.
or do not go to
Ground
If the system is programmed through walk-around
desired levels.
programming, ensure that the load has been assigned to
the keypad button.
Power not present at keypad
• Circuit breaker tripped or OFF. Reset or turn ON
Hybrid Keypad
circuit breaker.
The FASST switch is pulled out.
Brass
Blue
• Push FASST switch in.
Silver
Black
Wiring
Green
Lighting
Load
• Wires shorted. Make sure the blue terminal is not
Ground
grounded or shorted to any other wires.
• Wiring error. Wire the Hybrid Keypad according to
the Installation section and the appropriate Wiring
Diagram.
Hybrid Keypad or
Lamps burned out or not installed
Remote Dimmer
• Replace or install lamps.
Brass
Blue
Dioded lamps
Silver
• If dioded lamps are being used, replace with
Black
non-dioded lamps.
Green
Lighting
Load
Out of RF range
Ground
• Reposition to be within 30 ft (9 m) of an RF signal
repeater.
Attached lights
Wiring
turn OFF shortly
• Wiring error. Wire the Hybrid Keypad according to
after being turned
the Installation section and the appropriate Wiring
ON.
Diagram.
Load is less than minimum load requirement
• Make sure the connected load meets the
Adapter
appropriate minimum load requirement for that
Wallplate
Mounting
control. See Load Specifications.
Adapter
Wallplate
Screws
All LEDs on the
The Hybrid Keypad is in Factory Settings mode and has
Hybrid Keypad
not been configured to work in a system.
flash when any
• Follow the steps in the system Setup Guide to program
button is pressed.
the Hybrid Keypad.
Wallplate is warm
Solid-state control dissipation
• Solid-state Hybrid Keypads internally dissipate
about 2% of the total connected load. It is normal
for Hybrid Keypads to feel warm to the touch during
operation.
Note: Refer to the system Setup Guide for additional troubleshooting
suggestions.
Returning Hybrid Keypads to Factory Settings
Returning a Hybrid Keypad to its Factory Settings will remove it from the
Wallplate adapter and wallplate
purchased separately.
system and erase all dimmer settings and keypad programming.
Step 1: Triple tap any button (except raise / lower) on the Hybrid Keypad. DO
NOT release after third tap.
Step 2: Keep the button pressed on the third tap until all the status LEDs start
to flash slowly (approximately 3 seconds).
Step 3: Immediately release the button and triple tap the button again. The
status LEDs on the Hybrid Keypad will flash quickly.
The Hybrid Keypad has now been returned to Factory Settings.
Warranty: For warranty information, please see the Warranty enclosed with the
product, or visit www.lutron.com/resiinfo

Advertisement

loading

Summary of Contents for Lutron Electronics RadioRA2 RRD-H2RLD

  • Page 1 NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. Lutron, Claro, Satin Colors, RadioRA and are registered trademarks and RadioRA 2 and FASS are trademarks of 7200 Suter Road Lutron Electronics Co., Inc. Coopersburg, PA 18036-1299 ©2011 Lutron Electronics Co., Inc. P/N 044-299 Rev. A 10/2011...
  • Page 2 NEC es una marca registrada de National Fire Protection Association, Quincy, Massachusetts. Lutron, Claro, Satin Colors, RadioRA y son marcas registradas y RadioRA 2 y FASS son marcas comerciales de 7200 Suter Road Lutron Electronics Co., Inc. Coopersburg, PA 18036-1299 ©2011 Lutron Electronics Co., Inc. P/N 044-299 Rev. A 10/2011...
  • Page 3 NEC est une marque de commerce déposée de la National Fire Protection Association, Quincy, Massachusetts. Lutron, Claro, Satin Colors, RadioRA et sont des marques de commerce déposées et RadioRA 2 et 7200 Suter Road FASS sont des marques de commerce de Lutron Electronics Co., Inc. Coopersburg, PA 18036-1299 ©2011 Lutron Electronics Co., Inc, tous droits réservés.
  • Page 4 NEC é uma marca registrada da National Fire Protection Association, Quincy, Massachusetts. Lutron, Claro, Satin Colors, RadioRA e são marcas registradas e RadioRA 2 e FASS são marcas da 7200 Suter Road Lutron Electronics Co., Inc. Coopersburg, PA 18036-1299 ©2011 Lutron Electronics Co., Inc. P/N 044-299 Rev. A 10/2011...

This manual is also suitable for:

Radiora2 rrd-h4sRadiora2 rrd-h3bsrlRadiora2 rrd-h6brlRadiora2 rrd-h1rldRadiora2 rrd-h5brl