Latched Alarm - TC Communications TC8614 User Manual

4 ch. 600? analog & dry contact over t1/e1 multiplexer
Table of Contents

Advertisement

Chapter 4 Tutorial
4.2

Latched Alarm

The front panel "ALM", "BPV", "CRC" and "SYNC" LEDs can display both
current and latched error conditions.
For example, if the "ALM" LED is on, and "SYNC" LED blinks twice, it indicates
that there are two "T1/E1 sync loss" after the last alarm reset.
To reset the alarm, press and hold the "R2" ("Reset Too") button for 3 seconds until
the "ALM", "BPV", "CRC", and "SYNC" LEDs are flashing. The alarm will reset
after the "R2" button is released.
See the table below for latched alarm definitions,
LED
ALM
BPV
CRC
SYNC
TC8614 Rev 1.4
User Manual
Normal
Current Error
Off
Flashing
Continuously
Off
Flashing
Continuously
Off
Flashing
Continuously
On
Flashing
Continuously
Latched Error Note
On
Blink
The number of blinks
indicates the number of
times the error condition
happens. (Max. 3 Blinks)
Blink
The number of blinks
indicates the number of
times the error condition
happens. (Max. 3 Blinks)
Blink
The number of blinks
indicates the number of
times the error condition
happens. (Max. 3 Blinks)
Latched Alarm
4-2

Hide quick links:

Advertisement

Table of Contents
loading