Mitsubishi Electric MXZ-4C36NAHZ Technical & Service Manual page 118

Split-type, heat pump air conditioners
Hide thumbs Also See for MXZ-4C36NAHZ:
Table of Contents

Advertisement

(1) Operation summary of the linear expansion valve
LEV
2
1
M
4
1
5
3
<Output pulse signal and the valve operation>
Output
(Phase)
1
2
3
1
ON
ON
OFF
2
OFF
ON
ON
3
OFF
OFF
OFF
4
OFF
OFF
OFF
(2) Linear expansion valve operation
Open
Close
A
Close
B
Extra tightening (about 32 pulse)
OCH573E
Output
4
5
6
7
8
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
Open
500 pulse
Opening a valve
all the way
Pulse number
branch box controller board
12V DC
Red
1
[4
Blue
2
[3
Orange
3
Yellow
4
[2
[1
White
5
Connector LEV-A
LEV-B
LEV-C
LEV-D
LEV-E
A
B
A
Drive circuit
[4
[3
[2
[1
B
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents