PROFESSIONAL MEDICAL PRODUCTS
User manual
VALUE DIGITAL THERMOMETER

Warning:

• Read instructions thoroughly before using digital thermometer.
• Choking Hazard: Thermometer cap and battery may be fatal if swallowed. Do not allow children to use this
device without parental supervision.
• Do not use thermometer in ear. Designed use is for oral, rectal, and armpit (axilla) readings only.
• Do not place thermometer battery near extreme heat as it may explode.
• Note: Use of the probe cover may result in a 0.1°C (0.2°F) discrepancy from actual temperature.
• It is recommended the performance should be checked every two years.
• Remove battery from the device when not in operation for a long time.
• The use of temperature readings for self-diagnosis is dangerous. Consult your doctor for the interpretation
of results. Self-diagnosis may lead to the worsening of existing disease conditions.
• Do not attempt measurements when the thermometer is wet as inaccurate readings may result. LIS. Do not bite
the thermometer. Doing so may lead to breakage and/or injury.
• Do not attempt to disassemble or repair the thermometer. Doing so may result in inaccurate readings.
• After each use, disinfect the thermometer especially in case the device is used by more than one person.
• Do not force the thermometer into the rectum. Stop insertion and abort the measurement when pain is present.
Failure to do so may lead to injury.
• Do not use thermometer orally after being used rectally.
• For children who are two years old or younger, please do not use the devices orally.
PLEASE READ CAREFULLY BEFORE USING
This digital thermometer provides a quick and highly accurate reading of an individual's body temperature.
To better understand its functions and to provide years of dependable results, please read all instructions first.
This thermometer is manufactured according to the system of EN12470-3:2000+A1:2009, ASTM E1112-00
(Reapproval 2011).
And the manufacturer is EN ISO 9001:2008 and EN ISO 13485:2012/AC:2012.

CONTENTS

1 Thermometer, 1 Owner's Manual, 1 Storage Case

PRODUCT ILLUSTRATION

Thermometric sensor
Thermometer tip

PRECAUTION

* The performance of the device may be degraded should one or more of the following occur:
- Operation outside the manufacturer's stated temperature and humidity range.
- Storage outside the manufacturer's stated temperature and humidity range.
- Mechanical shock (for example, drop test).
- Patient temperature is below ambient temperature.
* Portable and mobile RF communications such as microwave ovens and cell phones, which generate strong
electrical or electromagnetic fields, near the device, as they may become interference source to the device.

SYMBOL EXPLANATION

Direct Current
Type BF Applied Part
Caution, consult accompanying documents

SPECIFICATIONS

Type:
Range:
Accuracy:
Display:
Memory:
Battery:
Battery life:
Dimension:
Weight:
Using environment:
Storage and transportation
condition:
Gima S.p.A.
Via Marconi, 1 - 20060 Gessate (MI) Italy
gima@gimaitaly.com - export@gimaitaly.com
www.gimaitaly.com
LCD
Digital Thermometer (Not Predictive)
32.0°C~42.9°C (90.0°F~109.9°F) (°C/°F chosen by manufacturer )
±0.1°C, 35.5°C~42.0°C (±0.2°F, 95.9°F~107.6°F)
±0.2°C under 35.5°C or over 42.0°C
(±0.4°F under 95.9°F or over 107.6°F)
at ambient temperature of 18°C to 28°C (64.4°F to 82.4°F)
Liquid crystal display, 3 1/2 digits
For storing the last measured value
One 1.5 V DC. button battery (size LR41 )
Approx 200 hours
140mmx24mmx12rnm (L x W x H)
Approx. 11 grams including battery
Temperature: 5°C~40°C (41°F~104°F)
Relative humidity: 15%~95%RH
Temperature: -20°C-55°C (-4°F~131°F)
Relative humidity: 15%~95%RH
ON/OFF
Battery compartment
Batch code
Manufacturerer

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 25564 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Gima 25564

  • Page 1 Gima S.p.A. Via Marconi, 1 - 20060 Gessate (MI) Italy gima@gimaitaly.com - export@gimaitaly.com www.gimaitaly.com PROFESSIONAL MEDICAL PRODUCTS User manual VALUE DIGITAL THERMOMETER Warning: • Read instructions thoroughly before using digital thermometer. • Choking Hazard: Thermometer cap and battery may be fatal if swallowed. Do not allow children to use this device without parental supervision. • Do not use thermometer in ear. Designed use is for oral, rectal, and armpit (axilla) readings only. • Do not place thermometer battery near extreme heat as it may explode. • Note: Use of the probe cover may result in a 0.1°C (0.2°F) discrepancy from actual temperature. • It is recommended the performance should be checked every two years. • Remove battery from the device when not in operation for a long time. • The use of temperature readings for self-diagnosis is dangerous. Consult your doctor for the interpretation of results. Self-diagnosis may lead to the worsening of existing disease conditions. • Do not attempt measurements when the thermometer is wet as inaccurate readings may result. LIS. Do not bite the thermometer. Doing so may lead to breakage and/or injury. • Do not attempt to disassemble or repair the thermometer. Doing so may result in inaccurate readings. • After each use, disinfect the thermometer especially in case the device is used by more than one person. • Do not force the thermometer into the rectum. Stop insertion and abort the measurement when pain is present. Failure to do so may lead to injury. • Do not use thermometer orally after being used rectally. • For children who are two years old or younger, please do not use the devices orally. PLEASE READ CAREFULLY BEFORE USING This digital thermometer provides a quick and highly accurate reading of an individual’s body temperature. To better understand its functions and to provide years of dependable results, please read all instructions first. This thermometer is manufactured according to the system of EN12470-3:2000+A1:2009, ASTM E1112-00 (Reapproval 2011).
  • Page 2 Figure 4 Figure 5 CLEANING AND DISINFECTION Wipe the thermometer with a soft clean cloth. For stubborn stains, wipe the thermometer with a cloth that has been dampened with water or a neutral detergent solution and then wring thoroughly. Finish by wiping with a soft dry cloth. Observe the following to prevent damage to the thermometer. - Do not use benzene, thinner, gasoline or other strong solvents to clean the thermometer. - Do not soak the sensing section in alcohol for long periods of time or attempt to sterilize it using hot water (water at a temperature of 50°C (122°F) or higher). - Do not use ultrasonic washing to clean the thermometer. LIMITED WARRANTY The thermometer is guaranteed for one year from the date of purchase. If the thermometer does not function properly due to defective components or poor workmanship, we will repair or replace it free of charge. All components are covered by this warranty excluding the battery. The warranty does not cover damages to your thermometer due to improper handling. To obtain warranty service, an original or copy of the sales receipt from the original retailer is required. Disposal of this product and used batteries should be carried out in accordance with the national regulations forthe disposal of electronic products. 25564 / KD-101 Kellyunion Electronics Co., Ltd No. 114, Five Star Village, Jiangkou Town Hanjiang District 3511115 Putian, Fujian PEOPLE’S REPUBLIC OF CHINA Made in China 0123 Landlink GmbH Dorfstrasse 2/4, Emmendingen, 79312 Germany...