Advanced Mode
Click the "Advanced Mode" button in the left of the GUI screen to see all available user programmable options.
With Advanced Mode, additional user programmable features can be selected using the button text. In the left
side of the Advanced Mode Screen, click on the Tiles Selector to display the register to view or change. Then
change a register one bit at a time by clicking on the desired bit. The value of the bit is display right next to the
bit-name button.
Note that the far right side of the screen contains a scroll down button to scroll down to additional registers since
the Tile Screen can only display up to 8 bytes at once.
Figure 13 – GUI Advanced Mode
Button Descriptions
Read: Clicking on this button reads the ACT88325 registers and displays them in the GUI. Note that this reads
all registers. Active-Semi recommendspreading registers each time the ACT88325 powers-up to acquire the
initial register settings.Active-semi also recommends reading registers after making changes to them.
Immediately reading the registers after a write confirms the changes were properly stored.
Figure 14 – Read Button