Tr UBS Series Brushless DC Motor Driver User's Manual
Item
External speed
potentiometer
Speed setting scale
Power LED (Green)
ALARM LED (Red)
RUN/STOP Switch
Motor connector
AC power input
connector
Acceleration/Deceleration
time potentiometer
Input/Output signal
connector
※1.Acceleration/Deceleration time will be different from the load type (Ex:Inertia,friction)
※2. 「 L」means contact connected with 「-COM」; 「 H」means no connect (About the details please refer
to the wiring)
Regulating the motor speed「Clockwise rotation」from slow to fast
0~100 total 10 scales
Scales-Speed contrast chart please refer to the Page 8
When AC power is on, the 「POWER」green light on the front panel will lit up
The protection function activated, motor will stop and the 「ALARM」red light lit up
during motor over load/ driver low voltage/ driver over voltage
The motor runs or stops which controlled by switch
Switching to the 「RUN」side→motor starts to run
Switching to the 「STOP」side→motor comes to a natural stop
Please insert the motor cable
Please input the AC power voltage according to the specs of driver
「AC」contact:Please connect power line N and L
「FG」contact:Please contact to frame ground of the system
「NC」contact:Not used
Note:The mark of driver voltage specs
「-1」indicates→Single phase AC110~115V±15% 50/60Hz
「-2」indicates→Single phase AC220~230V±15% 50/60Hz
SS(Slow-start)Acceleration time max 8 sec( 0~2000RPM within no load)
SD(Slow-down)Deceleration time max7 sec( 2000RPM~0RPM within no load)
Terminal
No.
name
1
STOP/RUN
2
BRAKE
3
CW/CCW
4
A.R.
5
S.O.
6
A.O.
7
-COM
Functions
Name of functions
STOP/RUN
Brake stop
Clockwise rotation
input/Counterclockwise
rotation input
ALARM release
Speed output signal
ALARM output signal
Output signal power GND
6
Functions
Input signal level 「 L」 →Start
「H」→Stop ※2
Input signal level「L」→
Brake stop 「H」→Stop
normally
Input signal level 「 L 」 →
Counterclockwise rotation
「H」→Clockwise rotation
Alarm Reset, input
「Negative trigger signal」 →
ALARM release
Used when monitoring the
rate of rotation, pulse
signals output 12Pulse/
rotation
The signal is output when
motoroverload/overspeed/
overheat/ driver
overvoltage/driver low
voltage/motor cable broken.
At the same time motor will
stop normally
Ground terminal for
input/output signals and
external DC power GND