CORNET
ED-88TPlus Electrosmog meter user's manual
CORNET Microsystem Inc., ED-88Plus Electrosmog meter is a Tri-mode device for quick measurement of
both High frequency RF Electromagnetic wave field s
(
)
Magnetic field level(
Gauss Tesla , and Low frequency (
,
)
an excellent device for individual or company with Electromagnetic wave safety concerns. It has RF
bandwidth of
100
MHz
to GHz w
8
ith high sensitivity (0.5
50
Hz to KHz) with sensitivity of 0.1uT to 60uT(1mG-600
1
bandwidth of
50
Hz
-50KHz with sensitivity of
10 /
v m to
2.7
GHz can detect very short burst of digital RF down to
)
Applications:
- High frequency RF Electromagnetic wave field strength, power density and frequency measurement
- Low frequency LF Magnetic field measurement (
Gauss meter function
- Low frequency ELF Electric field measurement E ( -field meter function)
- Mobile phone base station antenna radiation power density measurement
- Wireless communications, Analog
&
Digital RF
(
AM FM TDMA GSM DECT CDMA,3 ,4
- RF power measurement for transmitters
- Wireless LAN Wi
(
-Fi Bluetooth Ultra
),
,
-wide-band detection installation optimization
- Spy camera wireless bug finder
,
, IOT devices
- Cellular Cordless phone ra
/
diation safety level Electrical Utilities SMART
,
- AC power line High voltage tower power Transformer motors and small appliance EMF
,
,
- Microwave oven leakage detection
- Personal living environment EMF safety evaluation
Usage guide:
(1)
Put the V battery in the
9
ED88Plus, Handle the unit with right hand in vertical direction and
volume power switch
/
to turn on the power it will come up with RF
,
(2)
The RF sensor is located in the left hand side of the ED88PLus; the LF sensor is located in the right
hand top side of the ED88Plus, the E-field sensor is located in the middle top side of the ED88Plus,
please do not cover the sensor area with hand or other objects.
(3)
There are 4 push button on the ED
88
Plus
: "Mode", "Hold", "LIGHT", and "UNIT" button, "MODE"
button is used to switch in between RF mode, two LF modes, and E-field mode. The "Hold" button is
used to freeze the data reading of the ED88Plus.
(4)
RF mode: measured RF field strength power density is shown on the digital LCD display
/
with dBm v m or mw m 2
(
, / ,
/
).
8 LED lights with Red Yellow and Green color on the right hand
side of LCD window are used for quick RF signal level indications. 3 Red LEDs are used to
indicate the
3
safety
ranges. The power level of each LED can be found in the table on the
ED88Plus back panel. Frequency of signal detected is displayed on the LCD display.
(5)
LF mode: measured LF magnetic field strength is shown on the digital LCD display with uT
and mGauss). Two LF modes can be selected by "Mode" button: ( ) a LF30mode (0.1mG-10
and b ( )LF
600
mode
(1mG-600
mG
).
8 color LED lights are also available to show the relative
strength of the magnetic field.
(6)
E-field mode: measured ELF electric field strength is shown on the digital LCD display with V m
(7)
Histogram:
previous
30
signal level readings are recorded and shown as moving graph
on the LCD display for RF, LF, and E-field modes. It can be used for finding direction of signal source
and recording bursts from digital RF signals such as signals from AC smart meter.
(8)
Hold &UNIT:
HOLD button can be used to halt the data measurement of the ED88Plus, a "HOLD"
Mark will shown on the LCD screen to indicate the "Hold" condition. Push the "HOLD" button again the
ED88Plus will exit from the "Hold" condition. "UNIT" button can select the mw m v m or dBm unit
(9)
MAX:
Maximum measured data value since the last power-on is shown on the LCD display.
(10) Average:
average or peak average value is displayed on the LCD with "A" or "P" mark It can be
used to estimate the duty cycle of the digital RF burst signals or the average of peak signal level.
(11) Sound function & LCD backlight:
go into the "Hold mode" first, then toggle the "UNIT" button
in sequence to turn-on/off the Sound signature function, a "S" mark on the LCD indicates the sound
mode is on). Wheel Volume control can adjust the sound level.
2
very low level RF signals down to
(
0.05
uw m
/
The "LIGHT" button can be used to turn on off the LCD back light
/
back light or the sound when it is not needed to reduce the battery current consumption.
c2017 CORNET Microsystems Inc
., 1400
Coleman Ave C
# 28
www cornetmicro com
.
.
ED
88 Plus
T
12/15/2017
12/15/2017
trength power density level
/
, Low frequency LF
(
ELF Electric Field V m
)
( / ) for living environments
w m 2
uw m 2 to
/
1.8
/
), LF bandwidth of
50
Hz to
10KHz (or
mG or
)
0.01
uT to uT
1
(0.1
mG to
10
mG , and E-field
)
1000 / .
v m The RF
Frequency display function (100MHz-
100
usec
.
)
/
,
,
,
,
G G)
,
,
METER radiation level
,
,
turn on the
meter mode.
,
,
(
mG
/ .
/ 2, / ,
.
Audio Sound can be used to detect
) especially for the modern digital RF burst signals.
. (Remember to turn-off the LCD
Santa Clara CA
,
95050
USA Tel
: (408)9690205
(12) SysSetup Menu: can be enabled by push and hold the "HOLD" button then push the "UNIT" button
to get into the SysSetup menu U
and use the " " < button to enable disable the function
( ) a EXIT:
exit the SysSetup menu return to normal mode
(b) RF level Unit select:
)
( ) c LED Level: used to adjust the color LED segment display level for custom safety standards
.
It is
OFF,-5,-10,-15, or -20
( ) d Average Frequency
/
(e) MAX Clear
_
bit: If the MAX Clear
button. If it is "OFF" the MAX value can be cleared only by power-off the meter.
(f) Alarm:
ON OFF or
/
be selected to trigger the audio Alarm
( ) e RESET:
reset to default (
(g) SAVE:
push the " " < button to save the changes of setup to EEPROM memory. Do not
power off meter Wait until save is done
changes will still functional but
(13) The LF
30
mode
: has high sensitivity (0.1mG-10
(50Hz – 1
segment display can go up to
The LF
600
mode
:
with sensitivity (1mG-600
When measuring the high frequency digital pulse type of
the LF
30
mode might have lower reading than the LF
coverage range of the LF
(14) While in LF (magnetic/electric field measurement) or E-field mode please hold the
get the good stable reading
reading caused by the Earth magnetic field or the induced electric field of nearby objects.
(15) AC Smart Meter radiates RF signal in short burst every few minutes use MAX function and
Histogram function of ED88, and wait a few minutes to capture the RF signals from smart meter.
)
Field strength power density readout
/
ED88Plus use
8
high brightness LED to indicate the measured po
Indications of three countries
.
RF
LED
Power
color
level
-5 dBm
RED3
up
RED2
-10 dBm
RED1
-15 dBm
YELLOW3
-20 dBm
YELLOW2
-25 dBm
YELLOW1
-30 dBm
GREEN3
-35 dBm
-40 dBm
GREEN2
down
. se the " " > button to move the cursor in the Menu
/
s In the SysSetup menu:
,
2
select default mw m
/
, / ,
v m or dBm mode when meter is powered on.
dB use -20dB for
. (
"SBM2008 Building Biology Testing Methods" )
: select Peak average, All average or
,
Frequency of MAX value display.
_
is "ON" the MAX value can be cleared by toggling the "HOLD"
one of the 8 trigger levels(0, -5,-10,-15,-20,-25,-30,-35dBm can
. *(
Alarm function is used
2
mw m
/
,LED Level OFF MAX CLEAR ON
,
_
,
! (EXIT without SAVE to memory the
,
it will lost if the meter is power-off ).
mG but with lower frequency range
),
KHz to reduce the high frequency noise.
)
(The Histogram and LED
30
mG
)
mG , has higher frequency coverage (50Hz -10
)
/
signals,(such as switching power supply)
600
mode this is due to the lower frequency
,
30
mode
.
,
,
avoid fast moving of the
ED88 to prevent the sudden change of the
,
:
wer density with
.
*Action is reference to ICNIRP (
for reference only
LF
600/
LF
30
E-
RF Power
level
field
Indication
density
level
30
uT uT
/3
500
Italy RF safety
2
0.18 / w m
up
v m
/
standard
(0.1 /
200
Swiss RF safety
2
0.058 / w m
20
uT uT
/2
v m
/
standard
(0.04 /
100
Russian RF safety
2
0.018 / w m
10
uT uT
/1
v m
/
standard
(0.02 /
75
2
5.8
mw m
/
5
uT
/0.5
uT
v m
/
50
2
1.8
mw m
/
2
uT
/0.2
uT
v/m
30
2
0.58
mw m
/
0.5
uT
/0.05
uT
v m
/
20
WiFi Wireless LAN
2
0.18
mw m
/
0.2
uT
/0.02
uT
v m
/
typically in this range
0.2
uT
/0.02
uT
10vm
Some signal source
2
0.06
mw m
/
down
around
)
in RF mode only).
, Alarm OFF,PeakAvg).
KHz
).
ED88 steady to
3
safety
).
Action
Caution!
2
w m
)
Caution!
2
w m
)
Caution!
2
w m
)
Safe*
Safe*
Safe*
Safe*
Safe*