Huawei BBU3900 Installation Manual page 47

Hide thumbs Also See for BBU3900:
Table of Contents

Advertisement

Installing the BBU in the OMB
c
Installing the BBU Cables
7. Install the FE/GE cable
(FE/GE transmission mode).
The shielded straight-through cable
must be used as the FE/GE Ethernet
cable.
8. Install the CPRI optical cable.
Insert the DLC connectors labeled 2A and 2B at one end of the CPRI optical cable into the
optical module on the GTMU, and then insert the DLC connectors labeled 1A and 1B at
the other end into the optical module on the RRU.
1. Insert the optical module into the CPRI0, CPRI1,
CPRI2, CPRI3, CPRI4 or CPRI5 port.
2. Turn outwards the puller on the optical module.
Optical module
Puller
The single-mode optical module is labeled "SM"
and multi-mode optical module is labeled "MM".
If the puller of an optical module is blue, the
module is a single-mode optical module. If the
puller of an optical module is black or grey, the
module is a multi-mode optical module.
3. Remove the dustproof caps from the
optical connectors.
4. Insert the optical connector at one end of the CPRI optical cable into the optical module.
Lead the CPRI optical cable out of the cabinet along the left side of the cabinet.
a
a
If both ends of the optical cable are the LC
connectors, the TX and RX ports on the BBU
are respectively connected to the TX and RX
ports on the RRU.
46
c
b
b
c