DAS Vantec-20A User Manual

DAS Vantec-20A User Manual

Vantec series

Advertisement

User's Manual
VANTEC-20A / VANTEC-118A
Antes de utilizar el equipo, lea la sección
"Precauciones de seguridad" de este manual.
Conserve este manual para futuras consultas.
Before operating the device, please read the
"Safety precautions" section of this manual.
Retain this manual for future reference.

Advertisement

Table of Contents
loading

Summary of Contents for DAS Vantec-20A

  • Page 1 User's Manual VANTEC-20A / VANTEC-118A Antes de utilizar el equipo, lea la sección “Precauciones de seguridad” de este manual. Conserve este manual para futuras consultas. Before operating the device, please read the “Safety precautions” section of this manual. Retain this manual for future reference.
  • Page 2: Table Of Contents

    WARRANTY DECLARATION OF CONFORMITY INTRODUCTION CONFIGURATIONS 7 - 10 2 x VANTEC-20A + 2 x VANTEC-218A 6 x VANTEC-20A + 2 x VANTEC-118A 6 x VANTEC-20A + 2 x VANTEC-218A 6 x VANTEC-20A + 4 x VANTEC-118A LINE DRAWINGS SPECIFICATIONS...
  • Page 3: Safety Precautions

    TRD-2 trípode modelo TRD-2, con pies a 55 cm del eje del trípode, es: tripod, with legs spread 55cm from the central pole, is: VANTEC-20A ------------->150 cm VANTEC-20A ------------->150 cm El colgado del equipo sólo debe realizarse utilizando los herrajes The appliance should be flown only from the rigging points and by de colgado recomendados y por personal cualificado.
  • Page 4: Warranty

    GARANTÍA Todos nuestros productos están garantizados por un periodo de 24 meses desde la fecha de compra. Las garantías sólo serán válidas si son por un defecto de fabricación y en ningún caso por un uso incorrecto del producto. Las reparaciones en garantía pueden ser realizadas, exclusivamente, por el fabricante o el servicio de asistencia técnica autorizado.
  • Page 5: Declaration Of Conformity

    C/ Islas Baleares, 24 - 46988 - Pol. Fuente del Jarro - Valencia. España (Spain). Nota: Los textos completos de la declaración de conformidad para VANTEC- 12A, VANTEC-15A, VANTEC-20A y VANTEC-215A están disponibles en http://d.dasaudio.com/vK2D4. Note: The full text of the declaration of conformity for VANTEC-12A, VANTEC- 15A, VANTEC-20A and VANTEC-215A is available at http://d.dasaudio.com/vK2D4.
  • Page 6: Introduction

    Designed for use in arrays of up to 5 units, the VANTEC-20A is ideal for applications where the power and long- throw characteristics of large line arrays are not needed. Fast and simple deployment is guaranteed thanks to the exclusive DAS Click-Lock™...
  • Page 7: Configurations

    CONFIGURATIONS VANTEC- 218A VANTEC- POWER POWER POWER POWER Speaker cabling Units SC-2 2m XLR microphone signal balanced cable Accessories TRD-6 Stacking bracket for VANTEC-218A (max 4 u./max 1 u. using TRD-6/TRD-2), black Manual del Usuario / vantec series / User’s Manual...
  • Page 8 0.9m powerCON “jumper” NAC3FCB cable Accessories AX-VT20 Rigging bumper for VANTEC-20A (max 5 u.), black PL-VT20S Steel transport dolly for VANTEC-20A (max 4 u.), black PL-VT118S Wooden transport dolly for VANTEC-118A (max 2 u.), black Manual del Usuario / vantec series / User’s Manual...
  • Page 9 2 In/6 Out fully configurable DSP, 9 full bandwidth parametric band EQ on each channel, AudioCore/DASnet equipped Speaker cabling SC-1 1m XLR microphone signal balanced cable PWCONLINK-09 0.9m powerCON “jumper” NAC3FCB cable Accessories AX-VT20 Rigging bumper for VANTEC-20A (max 5 u.), black PL-VT20S Manual del Usuario / vantec series / User’s Manual...
  • Page 10 2 In/6 Out fully configurable DSP, 9 full bandwidth parametric band EQ on each channel, AudioCore/DASnet equipped Speaker cabling SC-1 1m XLR microphone signal balanced cable PWCONLINK-09 0.9m powerCON “jumper” NAC3FCB cable Accessories AX-VT20 Rigging bumper for VANTEC-20A (max 5 u.), black PL-VT20S PL-VT118S Manual del Usuario / vantec series / User’s Manual...
  • Page 11: Line Drawings

    AX-VT20 TRD-2 TRD-6 TRD-6 PL-VT118S PL-VT20S FUN-2-VT118 FUN-3-VT20 DAS Audio Group, S.L. continuously strives to enhance its products through investigation and development. All specifications are subject to change without prior notice. Manual del Usuario / vantec series / User’s Manual...
  • Page 12: Amplifiers

    Green LED indicates signal presence. 5) ON: Green LED indicates that the unit is ON. VANTEC series 6) SUB LEVEL: Potentiometer for adjusting the unit level. DAS Audio Group, S.L. (Valencia) LIMIT Model: VANTEC-118A MADE IN SPAIN LEVEL LOW-PASS SIGNAL...
  • Page 13: Description

    Keep in mind that any parameter changed in the DSP will remain with the same value until someone changes it again. The DAS array correction named Number Of Units is a parameter that compensates the amount of energy in the low-...
  • Page 14 HPF (High Pass Filter) By pressing the enconder (DAScontrol) the user can have access to the menu; rotate to navigate until selecting HPF: AUDIO MANAGEMENT MAIN MENU BACK No.ofU: HPF: Press the encoder: AUDIO MANAGEMENT MAIN MENU BACK No.ofU: HPF: Rotate the encoder and press to confirm one of the following”...
  • Page 15 Connect from your Waiting MASTER Master cabinet Master cabinet device to: connection CREATE NEW LINK CREATE NEW LINK VANTEC-20A-089E39 ---- Wait a minute ---- Connect from your Phone / tablet device to: in SLAVE: R mode Phone / tablet VANTEC-20A-089E39...
  • Page 16 OPTIONS In this sub-menu the user can configure all the non-audio related options. Remember that in order to access each parameter it is necessary to push the encoder: OPTIONS MENU OPTIONS MENU OPTIONS MENU BACK BACK BACK BRIGHT: 0 BRIGHT: BRIGHT: CONTRAST: 0 CONTRAST: 0...
  • Page 17: On / Off

    Power can be daisy chained via the NC3FCB output connector (see details on product label). Pink Noise 1/3 Power Mains 230 Vrms IMPORTANT: Do not disconnect the unit while VANTEC-20A 1.5A in use. VANTEC-118A Ensure that the device is disconnected from the 2.2A mains by observing that the ON LED is turned off.
  • Page 18 Troubleshooting No sound from the unit. The input 1 - The signal source is sending no 1 - Check that the source is not muted meters in the screen do not show any signal. and is sending signal to the unit. signal presence.
  • Page 19: Rigging System

    Consult a certified professional if needed. All flying accessories that are not supplied Only experienced installers with adequate by DAS Audio are the user's responsibility. Use at knowledge of the equipment and local safety your own risk. regulations should fly speaker boxes. It is the user's...
  • Page 20 Similarly, to hide the slide we must act on the trigger as in (1) and push the slide up (4), releasing the trigger (3), finally. Now, if we attach this enclosure to another VANTEC-20A, we will hear a "clack" that indicates that both enclosures have locked. In addition, the angle between them will be 15º.
  • Page 21 The rigging frame AX-VT20 is suitable for hanging a maximum of 5 units of VANTEC-20A. It has 11 hook points for the lifting slings, numbered from front to back (see attached figure). To assure the vertical inclination of the entire column use the Ease Focus software, which will indicate which holes have to be used.
  • Page 22 TRD-2 and TRD-6 The VANTEC-20A unit has a tripod socket on its underside that allows a box angle between + 25º and -10º when placed on a TRD-2 tripod or on a TRD-6 pole. It is only possible to use one unit in this way.
  • Page 23 VANTEC-118A can be interlocked PL-VT118S with another, since they have slides equal to those of the VANTEC-20A. Manual del Usuario / vantec series / User’s Manual...
  • Page 24: Annex

    ANNEX : Line connections: unbalanced and balanced There are two basic ways to transport an audio signal with microphone or line level: Unbalanced line: Utilising a two conductor cable, it transports the signal as the voltage between them. Electromagnetic interference can get added to the signal as undesired noise. Connectors that carry unbalanced signals have two pins, such as RCA (Phono) and ¼”...
  • Page 25 46988 Fuente del Jarro Miami, FL. 33166 - U.S.A. Tower #34-36 Santa Efigênia, São Paulo Valencia, SPAIN TOLL FREE: 1 888 DAS 4 USA Singapore 039190 Brasil. CEP: 01208-000 Tel. +34 96 134 0860 Tel. +65 6549 7760 Tel. +551133330764...

This manual is also suitable for:

Vantec-118a

Table of Contents