Description
The GAQ40S3V3B is a new generation isolated
DC-DC converter that uses an industry standard
quarter-brick structure, and features high
efficiency and power density, operates from an
input voltage range of 36 V to 75 V, provides the
rated output voltage of 3.3 V and the maximum
output current of 40 A.
Operational Features
Input voltage: 36 - 75 V
Output current: 0 - 40 A
Low output ripple and noise
Efficiency: 93.5% (3.3 V, 40 A)
Mechanical Features
Industry standard quarter-brick (D x W x H,
with a baseplate): 57.9 mm x 36.8 mm x 12.7
mm (2.28 in. x 1.45 in. x 0.50 in.)
Weight: about
58
g
Protection Features
Input undervoltage protection
Output overcurrent protection (hiccup mode)
Output short circuit protection (hiccup mode)
Output overvoltage protection (hiccup mode)
Overtemperature protection
GLOBAL ENERGY EFFICIENCY SPECIALIST
Copyright© 2012 Huawei Technologies Co., Ltd. All Rights Reserved.
THIS DOCUMENT IS FOR INFORMATION PURPOSE ONLY, AND DOES NOT CONSTITUTE ANY KIND OF WARRANTIES.
36 - 75 V
3.3 V Output
Input
Control Features
Safety Features
(self-recovery)
40 A Current
GAQ40S3V3B
Remote on/off
Remote sense
Output voltage trim
UL60950-1 and CSA C22.2 No. 60950-1-07
Meet UL94V-0 flammability requirements
RoHS6 compliant
1
Negative
Logic

Advertisement

Table of Contents
loading

Summary of Contents for Huawei GAQ40S3V3B

  • Page 1 Output short circuit protection (hiccup mode)  Output overvoltage protection (hiccup mode)  Overtemperature protection (self-recovery)  GLOBAL ENERGY EFFICIENCY SPECIALIST Copyright© 2012 Huawei Technologies Co., Ltd. All Rights Reserved. THIS DOCUMENT IS FOR INFORMATION PURPOSE ONLY, AND DOES NOT CONSTITUTE ANY KIND OF WARRANTIES.
  • Page 2: Mechanical Diagram

    GAQ40S3V3B DC-DC Converter Technical Manual V1.4 Designation Explanation 1 — 48Vin, high performance, analog control quarter-brick 2 — Output current: 40 A 3 — Single output 4 — Output voltage: 3.3 V 5 — With a baseplate Mechanical Diagram Pin Description Pin No.
  • Page 3: Electrical Specifications

    GAQ40S3V3B DC-DC Converter Technical Manual V1.4 Electrical Specifications Conditions: T = 25°C (77°F), Airflow = 1 m/s (200 LFM), V = 48 V, unless otherwise notes. Parameter Min. Typ. Max. Units Notes & Conditions Absolute maximum ratings Input voltage Continuous...
  • Page 4 GAQ40S3V3B DC-DC Converter Technical Manual V1.4 Electrical Specifications Conditions: T = 25°C (77°F), Airflow = 1 m/s (200 LFM), V = 48 V, unless otherwise notes. Parameter Min. Typ. Max. Units Notes & Conditions Protection characteristics Input undervoltage protection Startup threshold...
  • Page 5: Characteristic Curves

    GAQ40S3V3B DC-DC Converter Technical Manual V1.4 Characteristic Curves Figure 2: Power dissipation (T = 25°C or 77°F) Figure 1: Efficiency (T = 25°C or 77°F) Figure 3: Thermal derating with airflow from V Figure 4: Thermal derating with airflow from V (–)
  • Page 6: Typical Waveforms

    GAQ40S3V3B DC-DC Converter Technical Manual V1.4 Typical Waveforms 1. During the test of input reflected ripple current, the input terminal must be connected to a 12 µH inductor and a 220 µF electrolytic capacitor. 2. Point B, which is for testing the output voltage ripple, is 25 mm (0.98 in.) away from the V (+) pin.
  • Page 7 GAQ40S3V3B DC-DC Converter Technical Manual V1.4 Typical Waveforms Conditions: T = 25°C (77°F), V = 48 V. On/Off On/Off Figure 9: Startup from On/Off Figure 10: Shutdown from On/Off Figure 12: Shutdown by power off Figure 11: Startup by power on...
  • Page 8: Remote On/Off

    GAQ40S3V3B DC-DC Converter Technical Manual V1.4 Remote On/Off Output Voltage Trim The output voltage can be adjusted according to Logic On/Off Pin Level Status the trim range specification by using the Trim pin. Enable Trim Up Negative Low level logic...
  • Page 9 GAQ40S3V3B DC-DC Converter Technical Manual V1.4 Recommend Reverse Polarity Input Undervoltage Protection Protection Circuit The converter will shut down after the input Reverse polarity protection is recommended voltage drops below the undervoltage protection under installation and cabling conditions where threshold for shutdown. The converter will start reverse polarity across the input may occur.
  • Page 10: Qualification Testing

    GAQ40S3V3B DC-DC Converter Technical Manual V1.4 Qualification Testing Parameter Units Condition High Accelerated Life Lowest operating temperature: -60°C (-76°F); highest operating Test (HALT) temperature: 110°C (230°F); vibration limit: 40 G Proof Of Screen (POS) 80 temperature cycles; 50% vibration limit stress: 20 G High Accelerated 4 temperature cycles;...
  • Page 11: Mechanical Consideration

    When hand soldering, the iron temperature should be maintained at 425°C (797°F) and applied to the converter pins for less than 5 seconds. The converter can be rinsed using the isopropyl alcohol (IPA) solvent or other proper solvents. HUAWEI TECHNOLOGIES CO., LTD. Huawei Industrial Base Bantian Longgang Shenzhen 518129 People's Republic of China www.huawei.com...

Table of Contents