Installation
▪ The user interface in the indoor unit acts as control center.
▪ The user interface used as a room thermostat needs to be
installed in the room that you want to control.
4
To connect the user interface
used as a room thermostat
1 Connect the cable of the user interface used as a room
thermostat to the indoor unit.
A14P
P1 P2
a
X1M
M
X 5
A14P
a
a
User interface used as a room thermostat
2 Fix the cable with cable ties to the cable tie mountings.
EKRUDAS
Daikin Altherma user interface used as room thermostat
4P500350-1A – 2017.12
1112
X5M
10 11a
12
13
14a
X2M
X13A
X9A
K3M
L N PE
X7M
X5M
P1 P2
3 Overview: Installation and configuration