Sams HDV-3232 User Manual For Use And Maintenance

Hd/sd sdi routing switcher 32x32

Advertisement

Quick Links

ENGLISH
Z10-3 edition 1
Code: 003.641
HDV-3232
HD/SD SDI routing switcher 32x32
USER MANUAL FOR USE AND MAINTENANCE
Read the instructions before using the device.
Keep this manual for periodic usage.
Sams elektronik d.o.o.
48 Zivka Davidovica st.
11050 Belgrade
Serbia
Tel/Fax: +381 11 3806 253
+381 11 2402 212
sams@sams.rs
www.sams.rs
Copyright © 1999 - 2014 Sams elektronik d.o.o.
Published: 20. february 2013.
Updated: 26. november 2014.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HDV-3232 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sams HDV-3232

  • Page 1 Keep this manual for periodic usage. Sams elektronik d.o.o. 48 Zivka Davidovica st. 11050 Belgrade Serbia Tel/Fax: +381 11 3806 253 +381 11 2402 212 sams@sams.rs www.sams.rs Copyright © 1999 - 2014 Sams elektronik d.o.o. Published: 20. february 2013. Updated: 26. november 2014.
  • Page 2 Any technical failure or deficiency that occurs during the warranty period specified on the invoice of the purchased equipment will be inspected and serviced by Sams elektronik doo or an authorized service center of the manufacturer, with the conditions set out in the warranty statement.
  • Page 3 In poor conditions the user may be exposed to shock. The symbol “exclamation mark in a triangle” is to alert the user to comply by the terms of use in user’s manual, which is supplied with the device. Sams elektronik d.o.o. • sams@sams.rs • www.sams.rs...
  • Page 4 Design and specifications of the device may change without prior notice. TECHNICAL SUPPORT AND SERVICE Sams elektronik has made every effort to ensure that the equipment works in perfect condition. In the event that problems that occur can not be resolved, or if you have any questions regarding this...
  • Page 5: Table Of Contents

    ADDRESSING REMOTE CONTROLS .................12 NETWORK SETUP ......................13 NETWORK ACCESS AND DEVICE CONTROL ..............13 PROBLEMS AND SOLUTIONS IN A NETWORK ENVIRONMENT ..........15 SOFTWARE SUPPORT ....................17 SOFTWARE ........................18 CONFIGURATION SOFTWARE FOR SLAVE COMMANDS ............23 NOTES .........................28 Sams elektronik d.o.o. • sams@sams.rs • www.sams.rs...
  • Page 6: Unpacking And Installation

    Strictly comply to all steps for proper connection of devices in the system. Places for fastening MAINTENANCE The system maintains only person authorized by Sams elektronik doo. Any voluntarily opening device, upgrading or servicing is strictly prohibited and is subject to warranty void, and the possibility of injury.
  • Page 7: Description

    Vertical interval switching per SMPTE RP 168-1993 Can function independently or be linked with other 32x32 routing switchers HDV-3232 is a compact 32x32 HD / SD SDI matrix which allows up to 1.5Gb/sec. HDV series is based on the latest Power down memory recovery technology that supports HD.
  • Page 8: Installation

    Status is represented by LEDs on the front panel POWER GREEN LED - indication of the presence of power supply. FUSE ERROR RED LED - indication of a faulty fuse. The device does not work. Replace the fuse. Sams elektronik d.o.o. • sams@sams.rs • www.sams.rs...
  • Page 9: Cp-3232, Master Remote Control 32X32

    UNDO option may not be called if the routing switcher powered on for the first time. Remote control saves the previous state connections in the event of a power failure or deliberate Sams elektronik d.o.o. • sams@sams.rs • www.sams.rs...
  • Page 10: Cp-32, Slave Remote Control 32X1

    PC. UNDO Use this option if you want to restore the previous state of the connection. Since this type of commands Sams elektronik d.o.o. • sams@sams.rs • www.sams.rs...
  • Page 11: Configuration And Connection, Graphic Example

    Use this option when you want to lock the entire panel. PC ENABLE LED flashes when the PC software is active. CONFIGURATION AND CONNECTION, GRAPHIC EXAMPLE RS-232, control via PC TCP-IP, ethernet External reference, BB or Power supply Tri-level sync AC230V/50Hz Sams elektronik d.o.o. • sams@sams.rs • www.sams.rs...
  • Page 12: Connectors

    Make sure that the selected address does not match with the already selected in another previously, addressed slave commands. Pressed button starts flashing. In this way, you will notice that selected address will be used for this command. After selecting release PANEL LOCK key. Sams elektronik d.o.o. • sams@sams.rs • www.sams.rs...
  • Page 13: Network Setup

    NETWORK ACCESS AND DEVICE CONTROL The device can be configured through the web browser. First, the device must be found in the local network. To do this, start the Sams Netfinder software double clicking on the icon. The software first scans for devices.
  • Page 14 Pressing the button in one of rows connects selected input to a destination from that row. NOTE: All changes across the network are not visible on the remote commands. Sams elektronik d.o.o. • sams@sams.rs • www.sams.rs...
  • Page 15: Problems And Solutions In A Network Environment

    If the software NETFINDER is not able to locate the device in the network try the following: 1. Right click on Local Area Connection 2. Select option “Change Windows Firewall settings” 3. When a window “Windows Firewall” opens select tab “Exceptions” 4. Click on button “Add program” Sams elektronik d.o.o. • sams@sams.rs • www.sams.rs...
  • Page 16 13. In the IP Address field enter 192.168.0.200 (can be some other IP) 14. Connect the UTP cable to the computer and the other side to the device. 15. Turn on device. 16. Wait the computer to show “10mb connected...” Sams elektronik d.o.o. • sams@sams.rs • www.sams.rs...
  • Page 17: Software Support

    16 to output 16, http://192.168.0.14/get_data?dst00=0&dst01=1&dst02=2&dst03=3&dst04=4&dst05=5&dst06=6&ds t07=7&dst08=8&dst09=9&dst10=10&dst11=11&dst12=12&dst13=13&dst14=14&dst15=15 NOTE: - If you use a web browser for programming, we recommend that it be Mozilla Firefox , with desabled ® options to cache the page. Sams elektronik d.o.o. • sams@sams.rs • www.sams.rs...
  • Page 18: Software

    3. If you want, you can change the name of the folder in the start menu. Press CONTINUE. If you want to cancel installation press CANCEL. Sams elektronik d.o.o. • sams@sams.rs • www.sams.rs...
  • Page 19 AUDIO 1 (AUDIO 1 - AUDIO2): Controls whether this kind of signal interconnect AUDIO 2 (DATA): Controls whether this kind of signal interconnect SOURCE NAME: Name of input DESTINATION NAME: Name of output Sams elektronik d.o.o. • sams@sams.rs • www.sams.rs...
  • Page 20 Double click the left mouse button over the default names of the sources, a window opens where you can rename the source. After renaming press OK. Type a new name in the field Sams elektronik d.o.o. • sams@sams.rs • www.sams.rs...
  • Page 21 V i d e o Audio 1 Audio 1 Audio 2 Audio 2 Audio1-2 Audio1-2 Data Data (grey) (yellow) (grey) (yellow) (grey) (yellow) (grey) (yellow) (grey) (yellow) The intersection and text for explanation Sams elektronik d.o.o. • sams@sams.rs • www.sams.rs...
  • Page 22 If you want to load some of saved status of connection, press LOAD button (Ctrl + O). LOAD option is turned off, if at startup program determines that the communication with the main command is disabled. Loading status as a document from your computer Sams elektronik d.o.o. • sams@sams.rs • www.sams.rs...
  • Page 23: Configuration Software For Slave Commands

    Double click the left mouse button over the default names of the destination, a window opens where you can rename the destination. After renaming press OK. Type a new name in the field Sams elektronik d.o.o. • sams@sams.rs • www.sams.rs...
  • Page 24 - PANEL ADDRESS: Selecting the addresses of slave control. - WRITE TO PANEL: Saving the configuration in remote control. - SOURCE BUTTON: Source buttons of selected remote control. - DESTINATION BUTTON: Destination button of selected remote control. Sams elektronik d.o.o. • sams@sams.rs • www.sams.rs...
  • Page 25 Each command in the system has its own address. Choose the command that you want to reconfigure in drop-down menu Panel Address. In the example shown in the figure (below), was selected slave command with address 1. In this case, the command CP-48 (48x1) is connected to the system. Sams elektronik d.o.o. • sams@sams.rs • www.sams.rs...
  • Page 26 ENTER key, which confirms the selected destination (picture below). For commands that have more than one destination, in the same way can be reconfigured. The drop-down menu to select the The selected destination is on the key destination on the key Sams elektronik d.o.o. • sams@sams.rs • www.sams.rs...
  • Page 27 LOADING A CONFIGURATION OF SLAVE COMMANDS FROM COMPUTER - LOAD FROM FILE Configured state of the keys on slave commands can be loaded as a document to your computer. Pressing the button LOAD FROM FILE window opens for loading (picture below). Sams elektronik d.o.o. • sams@sams.rs • www.sams.rs...
  • Page 28: Notes

    Routing switchers elektronik NOTES Sams elektronik d.o.o. • sams@sams.rs • www.sams.rs...

Table of Contents