Cal. 5050.B
English
User's Manual
Description of the display and control buttons
Display elements
Second hand
Minute hand
Hour hand
Minute counter
Hour counter
Centre stop-second
1
⁄
second counter
10
Date
Second counter
Minute counter
�
�
�
�
Push-button A
2 1
Hour counter
1
⁄
second counter
10
2 1
�
Push-button B
Minute counter
Centre stop-second
�
I
II
III
2 1
Hour counter
1
⁄
second counter
10
Push-button A
�
III
2 1
Push-button B
Second hand
�
I
II
III
2 1
�
I
II
III
2 1
Crown
�
I
II
1 7
Date
�
I
II
0 3
2 1
Control buttons
Push-button A
Crown
Push-button B
2 1
Chronograph:
Accumulated timing
Example:
Start:
(start timing)
�
Stop:
(e.g. 15 min 5 sec following
�
Restart: (timing is resumed)
�
�
*
Stop:
(e.g. 10 min 5 sec following
=
25 min 10 sec
(The accumulated measured time is shown)
Reset:
�
The 4 chronograph hands are returned to
their zero positions.
Please note:
* Following
, the accumulation of the
�
timing can be continued by pressing
push-button A
(Restart / Stop, Restart / Stop, ...)
Adjusting the chronograph
hands to zero position
Example:
One or several chronograph hands are not
in their correct zero positions and have to be
adjusted (e.g. following a battery change).
�
Pull out the crown to position III
(all 4 chronograph hands are in their
correct or incorrect zero position).
Keep push-buttons A and B depressed
�
simultaneously for at least 2 seconds
(the centre stop-second rotates by
360° � corrective mode is activated).
�
Setting the time
�
* Pull out the crown to position III
�
(the watch stops).
Turn the crown until you reach the correct
�
time 8:45.
* Push the crown back into position I.
�
Please note:
* In order to set the time to the exact second,
must be pulled out when the second
�
hand is in position «60» (I).
Once the hour and minute hands have been
set,
must be pushed back into position I
�
at the exact second.
Setting the date/time
Example:
– Date / time on the watch:
/ 1:25 AM
17
– Present date / time:
/ 8:30 PM
4
Pull out the crown to position II
�
(the watch continues to run).
Turn the crown until yesterday's date
�
appears
.
3
�
Ronda aG
CH-4415 Lausen/Switzerland
www.ronda-startech.com
Battery type: 395 (diameter 9.5mm x 2.6mm / SR 927 SW)
Accuracy: +20 / -10 seconds per month
In case your watch needs to be repaired or to raise claims
under a guarantee, please contact the point of sales
Minute counter
Second counter
2 1
Hour counter
1
⁄
10
2 1
Push-button B
Second counter
Minute counter
)
�
2 1
�
)
Hour counter
1
⁄
10
2 1
Push-button B
A
B
A
B
A
�
III
I
II
3 1
0 1
Second hand
0 3
0 4
Chronograph: Basic function
(Start / Stop / Reset)
�
�
Example:
Push-button A
Start: Press push-button A.
�
�
Stop:
to stop the timing, press
push-button A once more and read
the 4 chronograph counters:
4h / 20 min / 5 sec /
second counter
�
Zero positioning:
Press push-button B.
(The 4 chronograph hands will be reset to
their zero positions).
�
Chronograph:
Intermediate or interval timing
�
Example:
�
Push-button A
Start: (start timing)
�
Display interval:
�
Push-button B
e.g. 10 minutes 10 seconds (timing
�
continues in the background)
�
*
Making up the measured time:
�
(the 4 chronograph hands are quickly
second counter
advanced to the ongoing measured time).
Stop: (Final time is displayed)
�
�
Reset:
The 4 chronograph hands are returned to
their zero position
Please note:
* Following
, further intervals or inter-
�
mediates can be displayed by pressing
�
push-button B (display interval / make up
measured time, ...)
�
Adjusting the centre stop second
A
Single step
A
Continuous
�
Adjusting the next hand B
�
Adjusting the
1
⁄
second counter hand (position 6h)
10
A
Single step
A
Continuous
�
Adjusting the next hand B
�
Adjusting the minute counter hand
and the hour counter hand
(mechanical coupled)
A
Single step
A
Continuous
�
�
Returning the crown to position I
Termination of the chronograph hands
adjustment (can be carried out at any time).
Setting the date (quick mode)
Pull out the crown to position II (the watch
�
�
�
continues to run).
I
II
Turn the crown until the correct
�
date
appears.
1
Push the crown back into position I.
�
Please note:
During the date changing phase between
9 PM and 12 PM; the date must be set to the
�
date of the following day.
An extreme acceleration in setting the date
I
II
with quick mode can induce a false date indi-
cation. The synchronization is re-established
by setting the date from 01 till 31 (crown in
position II).
�
* Pull out the crown to position III
�
�
(the watch stops).
Turn the crown until the correct date
�
I
II
III
appears.
4
** Continue to turn the crown until the
�
correct time 8:30 PM appears.
Push the crown back into position I.
�
�
�
Please note:
I
II
III
* To set your watch to the exact second,
please refer to the chapter entitled «set-
�
ting the time».
** Please observe the AM/PM clock rhythm.
7
⁄
sec
10
1 x short
long
1 x short
long
1 x short
long
Need help?
Do you have a question about the 5050.B and is the answer not in the manual?
Questions and answers