When in doubt (e.g. when purchasing brand new)
contact an authorised service station or call the
FRIATEC service hotline +49 (0) 621 486 1533.
Only use generators working with frequencies within
the 44-66 Hz range.
Start up the generator and leave it running for half a
minute. If necessary adjust off-load voltage and limit
to voltage indicated by the technical data. Gen er a -
tor (power) safety fuse at least 16 A (slow acting).
WARNING!
Check input voltage of your FRIAMAT
unit before starting the fusion process. Your
FRIAMAT
®
input voltage of 190-250 volt.
When using an extension cable, please ensure suffi-
cient cross section:
- 2.5 mm
2
Always roll out cable fully before use!
Do not connect any other equipment to the same
generator while fusion is taking place!
At the end of the fusion process, first disconnect the
power cable from the generator and then shut off
the generator.
DANGER!
Danger to life! Never open your FRIAMAT
unit
whilst
FRIAMAT
®
specialist personnel at an authorised service
station! The replacement of a damaged mains
supply line may only be performed by an authori-
sed service station.
fusion unit has been designed for
up to 100 m
connected
fusion units may be opened only by
to
power
®
fusion
®
fusion
supply!