The lamp does NOT have DHCP enabled to auto allocate IP addresses - but you can
activate that from the Discovery Tool. This is likely to be the easiest and fastest way to
allocate a new IP address, provided that your network is DHCP enabled.
The lamp responds to multicast messages - and therefore does not need to have a valid IP
address for the Discovery Tool to find it. But it does require a valid IP address for
communication.
To change the IP address so you can communicate with the lamp you can either:
1. Run Discovery Tool. Single click on lamp to highlight it. Select <Network> from bottom
menu. Highlight DHCP option. Press save. Then return to Discovery Tool. Press Discover.
Lamp should now appear with a valid IP address. You can now double click lamp to navigate
to it. WARNING: Your network must have DHCP capability.
2. Run Discovery Tool. Single click on lamp to highlight it. Select <Network> from bottom
menu. Write in a new IP address and subnet mask - which must be compatible with your
network. Check with your IT manager. After changing the IP address and subnet mask,
press save. Press Discover.You can now double click lamp to navigate to it.
Alternatively, you can navigate directly to the lamp by typing in the IP address of lamp into a
web browser on a computer located on the same network as the lamps. To ensure
successful communications the IP address of the PC must be in the same IP address range
of the lamps.
Log-on using Operator/User or Administrator user names and passwords. Operator has
limited access rights. Administrator has full access rights.
Defaults (User Names & Passwords are case sensitive):
Users & Passwords
Operator
Administrator
In order to maintain maximum security of your system, you may want to consider changing
the passwords at the earliest opportunity – see page 23.
Take instant control of lamp by pressing Override button on home page. This will countdown
for 30 minutes to allow user to control and then will revert to standard settings automatically
or if the override button is deselected.
If you wish to have lamp operated via its integrated web browser – then ensure that local
control box on Settings/Groups page is ticked. This is the default. To operate the lamp via
VMS or Raytec software, then deselect the local control box.
Standard set up – see factory defaults below for all default settings.
The lamp will turn on/off automatically when the photocell detects it is dark/light@ 100%
(soft start) via the photocell.
The External Input will activate the lamp @ 100% (NOT soft start) for the duration of the
input provided the photocell detects it is dark.
External Output: activated by photocell, short circuit
Different Settings can be selected on Settings/Groups page. Settings must be saved for
them to take effect.
We recommend that you log off after using the lamp.